KING LPWV2715-CT24

KING LPWV2715-CT24 Vandal Resistant Heater Instruction Manual

Model: LPWV2715-CT24

1. Ọja Ipariview

The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

KING LPWV2715-CT24 Vandal Resistant Heater, front view

Aworan 1: Iwaju view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing its robust metal casing and grill.

Awọn ẹya pataki:

  • Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
  • Pic-A-Watt Elements: Allows for multiple wattage options to suit specific heating requirements.
  • Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
  • Idaabobo igbona ju: Integrated safety feature to prevent overheating.

2. Alaye Aabo

Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

  • Fifi sori ẹrọ itanna: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
  • Ilẹ: This heater must be properly grounded to reduce the risk of electric shock.
  • Ibi: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
  • Idaabobo igbona ju: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
  • Maṣe Bo: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
  • Itọju: Ge asopọ agbara ṣaaju ṣiṣe eyikeyi itọju tabi mimọ.

3. Package Awọn akoonu

Daju pe gbogbo awọn paati wa ati pe ko bajẹ lori ṣiṣi package naa:

  • KING LPWV2715-CT24 Vandal Resistant Heater Unit
  • Mounting Hardware (typically included)
  • Ilana Afowoyi (iwe yii)

Tí àwọn nǹkan kan bá sọnù tàbí tí wọ́n bá bàjẹ́, kàn sí olùpèsè rẹ lẹ́sẹ̀kẹsẹ̀.

4. fifi sori

IKILO: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.

4.1 Iṣagbesori Location

  • This heater is designed for indoor, wall-mount installation.
  • Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
  • Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).

4.2 Itanna Asopọ

  • The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
  • Awọn ti ngbona fa 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
  • Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
  • Rii daju pe gbogbo awọn asopọ wa ni wiwọ ati aabo.

5. Isẹ

Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.

5.1 Power Switch Settings

  • PA: The heater is completely off, and no heat or fan operation will occur.
  • FAN: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
  • gbigbona: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).

5.2 Wattage Selection (Pic-A-Watt)

The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.

6. Itọju

Ìtọ́jú déédéé máa ń mú kí ẹ̀rọ ìgbóná rẹ ṣiṣẹ́ dáadáa, kí ó sì pẹ́ tó. Máa yọ agbára kúrò níbi ẹ̀rọ ìdènà kí o tó ṣe àtúnṣe èyíkéyìí.

  • Ninu: Lorekore nu ode ti igbona pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
  • Awọn ile-afẹfẹ / Awọn iÿë: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
  • Ayewo: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.

7. Laasigbotitusita

Ṣaaju ki o to kan si atilẹyin alabara, tunview Awọn iṣoro ti o wọpọ ati awọn solusan wọnyi:

IsoroOwun to le FaOjutu
Alagbona ko ni tan-an.Kò sí ìpèsè agbára; Ẹ̀rọ ìfọ́mọ́ra ti bàjẹ́; Àwọn wáyà tí kò ní agbára.Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring.
Heater produces no heat, but fan runs.Switch in 'FAN' position; Heating elements failed; Overheat protection activated.Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection.
A máa ń lo ẹ̀rọ ìgbóná nígbà gbogbo.Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling.Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances.
Àwọn ariwo tàbí òórùn tí kò wọ́pọ̀.Loose components; Dust accumulation on elements; Motor issue.Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection.

Tí ìṣòro náà bá ń bá a lọ lẹ́yìn tí a bá ti gbìyànjú àwọn ìdáhùn wọ̀nyí, kan sí ìrànlọ́wọ́ àwọn oníbàárà tàbí onímọ̀ iná mànàmáná tó mọ̀ nípa rẹ̀.

8. Awọn pato

SipesifikesonuẸ̀kúnrẹ́rẹ́
BrandOBA
Nọmba awoṣeLPWV2715-CT24
Voltage277 Volts
Ampigba5.4 Amps
Wattage1500 Wattis
Awọn iwọn Ọja (D x W x H)4"D x 13.75"W x 22.75"H
Iwọn Nkan36 iwon
Iṣagbesori IruÒgiri Ògiri
Epo IruItanna
inu ile / ita gbangba LiloNinu ile
Pataki ẸyaOverheat Idaabobo
UPC093319183731
ASINB0G3SWW2XK

9. Atilẹyin ọja ati Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.

Olupese: KING Electrical Manufacturing

Webojula: www.king-electric.com (Eksampọna asopọ le, jọwọ ṣayẹwo osise naa webaaye)

© 2025 KING Electrical Manufacturing. All rights reserved.