1. Ifihan

The KETOTEK KT3200 is a versatile digital temperature controller integrated into a socket timer. It displays the measured temperature and allows users to set start and stop temperatures to control heating or cooling equipment. This device also features a time function for independent day and night temperature control. It is widely applicable in intelligent control systems for heating, refrigeration, brewing, reptile habitats, aquaculture, greenhouses, and general home use.

KT3200 Timer Socket Thermostat front and back view
Iwaju ati sẹhin view of the KT3200 thermostat with EU plug, showing display and sensor.

2. Aabo ikilo

Please read these safety warnings carefully before operating the device.

  • Before using this unit, inspect the plastic casing for any damage. Do not use the device if it appears damaged.
  • The relay has a maximum capacity of 16A. For resistive loads, use less than 14A. For inductive loads, use less than 2A.
  • Do not use this unit in environments with explosive gases, excessive steam, or high dust concentrations.
  • Ma ṣe gba awọn ọmọde laaye lati ṣiṣẹ ẹrọ naa.
  • Ma ṣe gbiyanju lati tu ẹrọ naa funrararẹ.

3. Ọja Ipariview ati Awọn iwọn

3.1. Device irinše

KT3200 Control Panel with Button Labels
KT3200 Control Panel and Button Functions
  • Bọtini M: Yipada ipo iṣẹ
  • Bọtini: Ṣe alekun iye
  • Bọtini O dara: Select / C°/F° key (Press for 3s to switch C/F)
  • - Bọtini: Bọtini dinku
  • Back / Reset Key: Tẹ fun 3s lati tunto
  • Atọka Iṣẹ Ijade: Imọlẹ ti nfihan ipo iṣẹjade.

3.2. Awọn iwọn

KT3200 Thermostat Dimensions
KT3200 Thermostat Dimensions
  • Ìbú: 5.8 cm
  • Giga: 11.8 cm
  • Ijinle: 3.2 cm
  • Awọn iwọn sensọ: 2.4 cm (length) x 0.5 cm (diameter)
  • Gigun Cable Sensọ: 290 cm (mita 3)

3.3. Available Plug Types

Various KT3200 Plug Types
KT3200 available in US, EU, FR, AU, and UK plug types.
  • US Iru
    US Type Plug
  • EU Iru
    EU Type Plug
  • FR Iru
    FR Type Plug
  • AU Type
    AU Type Plug
  • UK Iru
    UK Type Plug

4. Awọn ọna ṣiṣe

The KT3200 offers three distinct operating modes to suit various temperature control and timing needs.

4.1. M1 TC: Ipo Iṣakoso iwọn otutu

In this mode, the device controls heating or cooling based on a set start and stop temperature.

  • Eto: Define a 'start temperature' and a 'stop temperature'.
  • Ipo alapapo: Set the start temperature to be lower than the stop temperature. The device will activate the heating equipment when the measured temperature falls below the start temperature and deactivate it when it reaches the stop temperature.
  • Ipo itutu: Set the start temperature to be higher than the stop temperature. The device will activate the cooling equipment when the measured temperature rises above the start temperature and deactivate it when it falls to the stop temperature.
M1 TC Temperature Control Mode Display
Display showing M1 TC mode with measured, start, and stop temperatures.

4.2. M2 TC + Aago: Iṣakoso iwọn otutu ọjọ / alẹ

This mode allows for different temperature control settings during daytime and nighttime periods within a 24-hour cycle.

  • Eto: Set the current clock, Time 1 (start of day period), Time 2 (start of night period), TC 1 (temperature control settings for day), and TC 2 (temperature control settings for night).
  • Isẹ: During the daytime period (from Time 1 to Time 2), the device will operate according to the TC 1 program. During the nighttime period (from Time 2 to Time 1), it will switch to the TC 2 program.
M2 TC+Timer Day/Night Temperature Control Diagram
Diagram illustrating the 24-hour cycle for M2 TC+Timer mode, showing TC1 and TC2 periods.

4.3. Aago M3: Aago akoko Aago 2 Nikan

This mode functions purely as a timer, controlling the output based on two set time periods.

  • Eto: Set the current clock, Time 1 (ON start time), and Time 2 (OFF start time).
  • Isẹ: The output will be ON during the period from Time 1 to Time 2. The output will be OFF during the period from Time 2 to Time 1.
M3 Timer Mode Display
Display showing M3 Timer mode with ON and OFF times.

5. Awọn pato

Ẹya ara ẹrọApejuwe
Ibi ti ina elekitiriki ti nwa100 ~ 250VAC 50 / 60Hz
Iwọn iṣakoso iwọn otutu-40 ℃ ~ 120 ℃ / -72 ℉ ~ 176 ℉
Iwọn otutu℃/℉ Yipada
Eto Akoko0-24h / Daily ọmọ aago
Iṣakoso Yiye±1℃ / ± 1℉
Sensọ IruNTC10K/B3950
Ijade (EU/UK/FR/AU Plug)Max 16A / 230V
Ijade (Plug US)Max 15A / 120V
Awọn iṣẹ patakiReset function, Temperature calibration function, Memory function (except clock) when power off
Awọn ọna ṢiṣẹM1 (Iṣakoso iwọn otutu), M2 (Iṣakoso iwọn otutu + Aago), M3 (Aago Nikan)
USB Ipari3M
Iwọn Ifihan1.9 Inches & Labẹ
Ẹrọ SmartRara
Batiri To waRara
IjẹrisiCE

6. Itọju

To ensure the longevity and accurate performance of your KT3200 thermostat, follow these simple maintenance guidelines:

  • Ninu: Gently wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the plastic casing àti àwọn ohun èlò itanna.
  • Itọju Sensọ: Keep the temperature sensor clean and free from debris. Ensure it is not exposed to extreme physical stress or sharp objects that could damage the cable or probe.
  • Ibi ipamọ: Nigbati o ko ba wa ni lilo fun awọn akoko ti o gbooro sii, tọju ẹrọ naa ni itura, aye gbigbẹ kuro lati orun taara ati awọn iwọn otutu to gaju.

7. Laasigbotitusita

If you encounter issues with your KT3200 thermostat, consider the following troubleshooting steps:

  • Ẹrọ ti ko ni agbara: Ensure the device is securely plugged into a functional power outlet. Check the power supply voltage to ensure it is within the specified range (100~250VAC).
  • Awọn kika iwọn otutu ti ko tọ: Verify that the temperature sensor is properly connected and positioned in the area where temperature needs to be measured. Ensure the sensor is not damaged. You may use the temperature calibration function if you suspect a consistent offset.
  • Ijade Ko Muu ṣiṣẹ/Muṣiṣẹ: Check your set start and stop temperatures or timer settings (Time 1, Time 2) to ensure they are configured correctly for your desired operation. Confirm that the connected appliance is working correctly.
  • Ohun elo Ko dahun: Try performing a reset by pressing the 'Back / Reset' key for 3 seconds. This will revert settings to default, so reconfigure as needed.
  • Awọn ọran Iṣẹ Iṣẹ Iranti: Remember that only the clock needs to be reset after a power failure if the device was in M2 or M3 mode. All other data is saved.

Ti awọn iṣoro ba tẹsiwaju lẹhin igbiyanju awọn igbesẹ wọnyi, jọwọ kan si atilẹyin alabara.

8. Awọn imọran olumulo

  • Agbara Outage Imularada: The KT3200 features a memory function that saves all settings except the clock after a power failure. If operating in M2 (Temperature Control + Timer) or M3 (Timer Only) mode, remember to reset the clock upon power restoration. If in M1 (Temperature Control) mode, the device will automatically resume operation.
  • Iyipada Iwọn otutu: Easily switch between Celsius (℃) and Fahrenheit (℉) by pressing the 'OK' button for 3 seconds.
  • Iwapọ ohun elo: This thermostat is highly versatile and can be used for various applications such as controlling heaters in a room, maintaining optimal temperatures in incubators, regulating aquarium temperatures, or managing climate in greenhouses.