Haier YR-E17

Haier YR-E17 Wired Controller Instruction Manual

Model: YR-E17 (0150401331AM)

1. Ifihan

This manual provides detailed instructions for the installation, operation, and maintenance of your Haier YR-E17 Wired Controller for central air-conditioning systems. Please read this manual carefully before using the controller and keep it for future reference.

Iwaju view of the Haier YR-E17 Wired Controller with its multi-language instruction manual.
Iwaju view of the Haier YR-E17 Wired Controller with its multi-language instruction manual.

2. Alaye Aabo

  • Rii daju pe gbogbo awọn asopọ itanna jẹ ṣiṣe nipasẹ alamọdaju ti o peye.
  • Disconnect power to the air conditioning unit before installation or maintenance.
  • Má ṣe fi olùdarí náà hàn sí omi tàbí ọ̀rinrin tó pọ̀ jù.
  • Má ṣe gbìyànjú láti ṣí tàbí tún olùdarí náà ṣe fúnra rẹ. Tọ́ka sí àwọn òṣìṣẹ́ iṣẹ́ tó péye.

3. Ọja Ipariview

The Haier YR-E17 is a wired controller designed for seamless integration with Haier central air-conditioning units. It provides intuitive control over various functions of your air conditioning system, including mode selection, temperature adjustment, and fan speed settings.

Ẹyìn view of the Haier YR-E17 Wired Controller, showing the circuit board and wiring terminal block. The label indicates model 0150401331AM.
Ẹyìn view of the Haier YR-E17 Wired Controller, showing the circuit board and wiring terminal block. The label indicates model 0150401331AM.

4. Awọn pato

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣeYR-E17 (0150401331AM)
LoAmuletutu
Iru IbanisọrọIṣakoso Waya
ikanni1
Ṣe atilẹyin APPRara
IpilẹṣẹOrile-ede China
Awọn iwọn Package (isunmọ.)Gigun: 28 cm, Iwọn: 20 cm, Giga: 3 cm
Gross Weight (approx.)0.8 kg

5. Eto

The Haier YR-E17 Wired Controller requires professional installation due to its wired connection to the central air-conditioning unit. The following steps outline a general installation process:

  1. Iṣagbesori: Choose a suitable indoor location for the controller, typically at eye level and away from direct sunlight or heat sources that could affect temperature readings. Secure the controller to the wall using appropriate screws.
  2. Asopọmọra: Access the wiring terminal block on the rear of the controller (refer to the 'PRESS TO OPEN' label on the back). Connect the communication wires from your central air-conditioning unit to the corresponding terminals on the controller. Ensure correct polarity and secure connections. Refer to the specific wiring diagram provided with your air conditioning unit for precise connections.
  3. Asopọ agbara: Once wiring is complete, restore power to the central air-conditioning unit. The controller should power on and display initial settings.
  4. Iṣeto akọkọ: Follow the on-screen prompts or refer to the air conditioning unit's manual for any initial configuration steps required for the controller to communicate with the system.
Page from the instruction manual detailing 'Parts and Functions' and a diagram of the controller's display.
Page from the instruction manual detailing 'Parts and Functions' and a diagram of the controller's display.

6. Awọn ilana Iṣiṣẹ

The YR-E17 controller features an intuitive display and buttons for easy operation. Refer to the diagram below for button identification and basic functions:

Alaye view of the controller's display diagram from the manual, showing buttons for Mode, Fan, Time, Set, and various operational icons. Text describes mode switching functionality.
Alaye view of the controller's display diagram from the manual, showing buttons for Mode, Fan, Time, Set, and various operational icons. Text describes mode switching functionality.

Awọn iṣẹ bọtini:

  • TAN/PA: Press to power the air conditioning unit on or off.
  • Ipo: Press this key to cycle through available operating modes (e.g., Cooling, Heating, Fan, Auto, Dry). If using a Fresh Air unit, default 3 modes will circulate from cooling-heating-fan.
  • Àìpẹ: Ṣe atunṣe iyara àìpẹ (fun apẹẹrẹ, Kekere, Alabọde, Giga, Aifọwọyi).
  • Ṣeto: Used to confirm selections or enter/exit settings menus.
  • Àkókò: Used for setting timers or scheduling operations.
  • Atunṣe iwọn otutu: Use the up/down arrows (typically integrated with other buttons or as separate controls) to increase or decrease the desired temperature.

For detailed information on advanced settings and specific mode functionalities, please refer to the comprehensive manual that came with your air conditioning system.

7. Itọju

To ensure optimal performance and longevity of your Haier YR-E17 Wired Controller, follow these simple maintenance guidelines:

  • Ninu: Gently wipe the surface of the controller with a soft, dry cloth. Do not use abrasive cleaners, solvents, or wet cloths, as these can damage the display or internal components.
  • Ayewo: Periodically check the controller for any visible damage or loose connections. If any issues are observed, contact a qualified technician.
  • Yago fun Idilọwọ: Ensure that the controller's temperature sensor (if applicable, usually a small vent) is not obstructed by furniture, curtains, or other objects, as this can lead to inaccurate temperature readings.

8. Laasigbotitusita

If you encounter issues with your Haier YR-E17 Wired Controller, try the following basic troubleshooting steps:

  • Alakoso Ko Dahun: Check if the central air-conditioning unit has power. Ensure all wiring connections are secure. If the issue persists, power cycle the air conditioning unit (turn off at the breaker for a few minutes, then turn back on).
  • Awọn kika iwọn otutu ti ko tọ: Ensure the controller is not exposed to direct sunlight, drafts, or heat sources. Verify that the sensor area is not obstructed.
  • Awọn oran Ifihan: If the display is blank or showing errors, try power cycling the air conditioning unit. If the problem continues, professional service may be required.

Awọn imọran olumulo:

  • Ensure the controller is functioning correctly after installation by testing all modes and temperature adjustments.

9. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the documentation provided with your Haier central air-conditioning system or contact your authorized Haier service provider. Keep your purchase receipt as proof of purchase.

Awọn iwe aṣẹ ti o jọmọ - YR-E17

Ṣaajuview Itọsọna fifi sori ẹrọ Haier Smart Air 2: So Afẹfẹ afẹfẹ rẹ pọ
Itọsọna okeerẹ si fifi sori ẹrọ ati sisopọ air conditioner Haier Smart Air 2 rẹ si ohun elo Smart Air. Pẹlu awọn ilana igbesẹ-nipasẹ-igbesẹ fun iṣeto Wi-Fi, sisọpọ ẹrọ, ati laasigbotitusita fun awọn awoṣe bii YR-E16A, YR-E16B, YR-E17, ati YR-E17A.
Ṣaajuview Àwo Afẹ́fẹ́ Haier 3.5 kW Ìtọ́kasí Kíákíá fún Ẹ̀rọ Amúlétutù
Ìtọ́sọ́nà kíákíá fún ẹ̀rọ amúlétutù Haier Cassette 3.5 kW, àwọn ìwọ̀n tó wà, àwọn pàtó, àwọn ẹ̀yà ara ẹ̀rọ náà, fífi sori ẹ̀rọ náà, iṣẹ́ rẹ̀, àti àwọn ohun tí agbára náà nílò. Ó ní àwòṣe AB12CS2ERA(S) àti SKU 51029 nínú.
Ṣaajuview Ìtọ́sọ́nà Ìtọ́kasí Kíákíá fún Afẹ́fẹ́ Haier High Static Ducted 14.0 kW
Ìtọ́sọ́nà ìtọ́kasí kíákíá fún ẹ̀rọ amúlétutù Haier High Static Ducted (Model ADH140H1ERG), àlàyé àwọn ìlànà, ìwọ̀n, iṣẹ́, agbára tí a nílò, àti ìwífún nípa àtìlẹ́yìn.
Ṣaajuview Haier AD12MS1ERA Ducted Medium Static Air Conditioner 3.5 kW - Ìtọ́sọ́nà Ìtọ́kasí Kíákíá
Ìtọ́sọ́nà ìtọ́kasí kíákíá fún Haier AD12MS1ERA ducted medium static air conditioner. Ó ní agbára ìtútù 3.5 kW, agbára ìgbóná 4.0 kW, ìwọ̀n, àwọn ìlànà pàtó, àwọn ohun tí agbára ń béèrè, àti ìwífún nípa àtìlẹ́yìn.
Ṣaajuview Ìtọ́sọ́nà Ìtọ́kasí Kíákíá fún Afẹ́fẹ́ Haier AD12MS1ERA Ducted Medium Static 3.5kW Air Conditioner
Ìtọ́sọ́nà ìtọ́kasí kíákíá fún Haier AD12MS1ERA ducted medium static air conditioner (3.5kW cooling). Àwọn ẹ̀kúnrẹ́rẹ́ ìwọ̀n, àwọn pàtó, àwọn ẹ̀yà ara ẹ̀rọ, fífi sori ẹ̀rọ, iṣẹ́, àwọn ohun tí agbára ń béèrè, àtìlẹ́yìn, àti ìwífún ìbáṣepọ̀ pẹ̀lú ìrànlọ́wọ́.
Ṣaajuview Haier AD105S2SM5FA Ducted Low Profile Ìtọ́sọ́nà Ìtọ́kasí Kíákíá fún Ẹ̀rọ Afẹ́fẹ́ 10.5kW
Itọsọna itọkasi kiakia fun Haier AD105S2SM5FA ti a ti ni okun, pro kekerefile ẹ̀rọ amúlétutù, àwọn àlàyé pàtó, ìwọ̀n, iṣẹ́, àti àwọn ohun tí agbára nílò. Kọ́ nípa àwọn ẹ̀yà ara rẹ̀ àti ìtìlẹ́yìn rẹ̀.