ANENJI ANJ-6KP-LV-WIFI, ANJ-3KW-24V-LV-WIFI

ANENJI arabara oorun Inverter Afowoyi olumulo

Models: ANJ-6KP-LV-WIFI, ANJ-3KW-24V-LV-WIFI

1. Ifihan

This manual provides essential information for the safe and efficient operation of your ANENJI Hybrid Solar Inverter. This device is designed to integrate solar power, utility power, and battery power to provide a reliable energy supply for various applications.

Awọn ẹya pataki pẹlu:

  • Pure sine wave output for compatibility with sensitive electronics.
  • Supports various energy storage batteries, including lead-acid and lithium-ion.
  • Off-grid operation capability.
  • High MPPT tracking efficiency (up to 99.9%) for optimal solar energy harvesting.
  • Multiple protection functions for comprehensive safety.
  • Capacitive smart touch screen for intuitive menu-based operation.
  • Built-in Bluetooth and WiFi interfaces for remote monitoring and cloud platform access.
  • Parallel capability for up to 6 units to expand power output.
  • Detachable dust cover for harsh environments (ANJ-3KW-24V-LV-WIFI).
  • EQ function to optimize battery performance and extend lifecycle (ANJ-3KW-24V-LV-WIFI).
Ọja Awọn ẹya ara ẹrọ Loriview
Olusin 1: Pariview of product features and capabilities.

2. Awọn iṣọra aabo

Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

Awọn iṣọra Ọja
Figure 2: Important safety warnings and cautions.
  • IKILO: ewu ewu. Fifi sori gbọdọ wa ni ošišẹ ti pẹlu abojuto nitori ga batiri voltage ninu jara.
  • Ṣọra!! Má ṣe gbé ohunkóhun sí àárín apá tí ó tẹ́jú ti ẹ̀rọ inverter. Bí bẹ́ẹ̀ kọ́, ìgbóná lè pọ̀ jù.
  • Ṣọra!! Ma ṣe lo nkan anti-oxidant lori awọn ebute ṣaaju ki awọn ebute ti sopọ ni wiwọ.
  • Ṣọra!! Ṣaaju ṣiṣe asopọ DC ikẹhin tabi pipade DC breaker/disconnector, rii daju pe rere (+) gbọdọ ni asopọ si rere (+) ati odi (-) gbọdọ ni asopọ si odi (-).

The inverter is equipped with multiple protection functions for enhanced safety:

  • Idaabobo kukuru-kukuru
  • Aabo Idaabobo
  • Apọju Idaabobo
  • Lori-otutu Idaabobo
  • Kekere Voltage Idaabobo
  • Gaju gigatage Idaabobo
Multi-Protection Functions
Olusin 3: Pariview ti awọn ẹya aabo pupọ ti inverter.

3. Ọja Ipariview (Awọn eroja)

Familiarize yourself with the external components and interfaces of your inverter:

Ọja Pariview pẹlu awọn eroja ti a fi aami si
Figure 4: Labeled diagram of the inverter's external components.
  1. AC igbewọle
  2. AC iṣẹjade
  3. PV igbewọle
  4. Iṣagbewọle batiri
  5. Ilẹ-ilẹ
  6. RS485 ibaraẹnisọrọ ibudo
  7. WIFI ti a ṣe sinu
  8. Agbara titan/pa a yipada
  9. LCD àpapọ
  10. Atọka ipo
  11. Atọka gbigba agbara
  12. Atọka aṣiṣe
  13. Awọn bọtini iṣẹ
  14. NC O NO (Normally Closed / Normally Open contacts)
  15. Ni afiwe Port Communication
  16. Awọn olubasọrọ ti o gbẹ

4. Eto

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. It is highly recommended that installation be performed by a qualified professional.

4.1. Awọn Itọsọna fifi sori ẹrọ

  • Ensure the installation location is well-ventilated and free from flammable materials.
  • Mount the inverter securely on a vertical surface.
  • Maintain adequate clearance around the inverter for proper airflow and cooling.
  • Yago fun imọlẹ orun taara, awọn iwọn otutu giga, ati ọriniinitutu giga.

4.2. Awọn aworan wiwa

The following diagrams illustrate typical wiring configurations for the inverter:

Single-phase Mode Wiring Diagram
Figure 5: Wiring diagram for single-phase operation, showing connections for solar panels, utility grid, batteries, and loads.
Link Instructions Diagram
Figure 6: General connection diagram illustrating how the inverter links various power sources (solar, generator, utility) and a battery to home appliances.

4.3. PV Connection Guidelines

When connecting photovoltaic (PV) modules, observe the following critical parameters to prevent damage to the inverter:

PV Connection Guidelines
Figure 7: Important parameters for selecting and connecting PV modules.
  • Awọn ìmọ-Circuit voltage (Voc) of the serially-connected photovoltaic panels shall be lower than 500V. Overvoltage will result in damage to the inverter.
  • The open circuit (Voc) voltage of PV modules should be higher than the minimum battery voltage.

4.4. Iṣẹ́ tó jọra

The ANENJI Hybrid Solar Inverter supports parallel operation for increased power output. Up to 6 units can be connected in parallel to achieve a maximum output power of 36000W, suitable for larger household electricity needs.

Parallel Capability 6 units
Figure 8: Illustration of multiple inverters connected in parallel.

5. Awọn ọna ṣiṣe

The inverter offers flexible charging and operation modes to suit various energy management strategies:

5.1. Four Charging Modes

Four Charging Modes
Figure 9: Visual representation of the four available charging modes.
  • PV only: Agbara oorun nikan lo n gba agbara batiri.
  • Pataki pataki: Prioritizes charging from the utility grid, using solar as a secondary source.
  • PV pataki: Prioritizes charging from solar power, using the utility grid as a secondary source.
  • Mains/PV hybrid charging: Dynamically uses both utility grid and solar power for charging based on availability and settings.

5.2. Four Operation Scenarios

Four Ways to Link (Operation Scenarios)
Figure 10: Diagrams illustrating different inverter operation scenarios.
  • Operation with battery connected (Solar Power and AC Power available): The inverter manages power flow from solar, AC grid, and battery to supply loads and charge the battery.
  • Operation with battery connected (Solar Power and AC Power not available): The inverter supplies power to loads from the battery.
  • Operation without battery connected (Solar Power available): The inverter supplies power to loads directly from solar, or from solar and AC grid if available.
  • Operation without battery connected (AC Power available): The inverter supplies power to loads from the AC grid.

6. Awọn pato

Detailed technical specifications for the ANENJI Hybrid Solar Inverter models:

6.1. ANJ-6KP-LV-WIFI (6KW Model)

Product Parameters ANJ-6KP-LV-WIFI
Figure 11: Technical specifications for the ANJ-6KP-LV-WIFI model.
Ẹka Paramita Iye
AwoṣeWon won Power o wu6000W
O pọju agbara tente oke12000W
Won won wu Voltage110/120Vac (Single-phase)
Motor Loading Capacity4.8HP
Ti won won Igbohunsafẹfẹ50/60Hz
Iwajade WaveformIgbi ese mimọ
Yipada Time10ms (iye deede)
BatiriBatiri IruLithium-ion battery / Lead-acid battery / User-defined
Ti won won Batiri Voltage48Vdc
Voltage Ibiti40 ~ 60Vdc
Maximum Mains/Generator Charging Current100A
Maximum Hybrid Charging Current120A
Igbewọle PhotovoltaicNumber of MPPT Routes1
O pọju Input Power9,000W
Iṣawọle ti o pọju lọwọlọwọ27A
Maximum Open-circuit Voltage500V
MPPT Ṣiṣẹ Voltage Ibiti125 ~ 425V
Ìbáwọlé Àwọn Ohun Èlò/Ẹ̀rọ Amúṣiṣẹ́Iṣagbewọle Voltage Ibiti90 ~ 140V
Ibiti Igbohunsafẹfẹ Input50/60Hz
Fori apọju Lọwọlọwọ80A
Iṣẹ ṣiṣeMPPT Ipasẹ ṣiṣe99.9%
Maximum Battery-to-Inverter Efficiency93%
GbogboogboAwọn iwọn470*365*130mm (Without Bracket)
Iwọn15kg
Ipele IdaaboboIP20, For indoor use only
Ibaramu otutu-10~55°C, <45°C derating
Ariwo≤45dB
Ọna ItutuNi oye Air itutu
Akoko atilẹyin ọjaọdun meji 3
Ibaraẹnisọrọmodule ibaraẹnisọrọRS485/CAN/GPRS/WIFI/Bluetooth/4G/LAN (Optional)
PariviewIEC62109-1, IEC62109-2, EN61326-1:2013

6.2. ANJ-3KW-24V-LV-WIFI (3KW Model)

Product Parameters ANJ-3KW-24V-LV-WIFI
Figure 12: Technical specifications for the ANJ-3KW-24V-LV-WIFI model.
Ẹka Paramita Iye
AwoṣeAgbara3KVA / 3KW
Ni afiwe AgbaraRARA
Split phase operationRARA
IṣawọleOruko Voltage110/120Vac
Itewogba Voltage Ibiti95-140VAC (For personal computer), 65-140VAC (For Home Appliances)
Igbohunsafẹfẹ50/60Hz (Ṣawari aifọwọyi)
AbajadeOruko Voltage110/120VAC ± 5%
Agbara agbara6000VA
Igbohunsafẹfẹ50/60Hz
Fọọmu igbiPure Sine igbi
Akoko Gbigbe10ms (For personal computer), 20ms (For Home Appliances)
Ìṣiṣẹ́ tó ga jùlọ (PV sí INV)97%
Ìṣiṣẹ́ tó ga jùlọ (Bátírì sí INV)93%
Apọju Idaabobo5s@>= 140% ẹrù; 10s@110%~ 140% ẹrù
Crest ifosiwewe3:1
Ifojusi Agbara Gbigbawọle0.6~1 (inductive or capacitive)
BatiriBatiri Voltage24VDC
Lilefoofo idiyele Voltage27VDC
OverCharge Protection33VDC
Ọna gbigba agbaraCC/CV
Ṣaja oorun & AC ṢajaMax.PV Array Power4000W
Solar Ṣaja IruMPPT
PV Array Open Circuit Voltage500VDC
PV orun MPPT Voltage Ibiti60VDC ~ 450VDC
Ìṣíṣẹ́ Ìṣíṣẹ́ Oòrùn Tó Pọ̀ Jùlọ18A
Iṣẹ́ Àkókò Ìgbara Líle Tó Pọ̀ Jùlọ80A
Max.Charge Lọwọlọwọ100A
Ti araDimensions,D x W x H(mm)312.4x350x114.5
Package Dimensions,D x W x H(mm)475x390x180
Àdánù Apapọ (Kg)8.5
Ibaraẹnisọrọ InterfaceGbẹ olubasọrọ + RS485 + WIFI
AyikaAwọn iwọn otutu ti nṣiṣẹ-10°C si 50°C
Ibi ipamọ otutu-15°C ~ 50°C
Ọriniinitutu5% si 95% Ọriniinitutu ibatan (ti kii ṣe itunnu)
Idaabobo IngressIP21

7. Itọju

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Ninu: Keep the inverter's exterior clean and free from dust. Use a dry cloth; do not use liquid cleaners. Ensure ventilation openings are not blocked.
  • Awọn isopọ: Lojoojumọ, ṣayẹwo gbogbo awọn asopọ ina (PV, batiri, titẹ sii AC/output) fun wiwọ ati awọn ami ibajẹ.
  • Afẹfẹ: Ensure the inverter has adequate ventilation to prevent overheating. Clear any obstructions around the cooling fans.
  • Ilera Batiri: If using lead-acid batteries, regularly check their water levels and terminal connections. For all battery types, monitor their state of charge and overall health via the inverter's display or monitoring app.

8. Laasigbotitusita

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, consult the detailed troubleshooting guide in the full product manual (if available) or contact technical support.

  • Ko si Agbara/Ifihan: Check all power connections, including AC input, battery, and the ON/OFF switch. Ensure the battery is adequately charged.
  • Inverter Not Producing Output: Verify that PV input is sufficient, battery voltage is within operating range, and AC input (if used) is present. Check for any fault indicators on the LCD display.
  • Ikilọ Apọju: Reduce the connected load. Ensure the total power consumption of your appliances does not exceed the inverter's rated output power.
  • Ìkìlọ̀ Ojú Òtútù Tó Lò Jù: Check for proper ventilation. Ensure the inverter is not in direct sunlight or an enclosed space. Clean any dust from the cooling fins.
  • Communication Issues (WiFi/Bluetooth): Ensure the inverter is within range of your WiFi router or Bluetooth device. Check network settings and ensure the monitoring app is updated.

9. Awọn imọran olumulo

  • Optimize PV Array: Ensure your solar panel array's voltage and current are within the MPPT operating range for maximum efficiency.
  • Ibamu Batiri: Always use compatible battery types (lead-acid or LiFePO4) and ensure correct voltage matching (24V for 3KW model, 48V for 6KW model).
  • Abojuto latọna jijin: Utilize the built-in WiFi and Bluetooth features with the dedicated app for convenient remote monitoring of your system's performance and status.
  • Isakoso fifuye: Be mindful of your total load, especially during peak usage, to avoid overloading the inverter.
  • Awọn imudojuiwọn famuwia: Periodically check for firmware updates to ensure your inverter operates with the latest features and improvements.

10. Atilẹyin ọja ati Support

The ANENJI Hybrid Solar Inverter comes with a 3-year warranty period, as specified in the product parameters. For technical support, warranty claims, or any inquiries, please contact your vendor or the manufacturer directly. Ensure you have your product model number and purchase details ready when seeking support.

Awọn iwe aṣẹ ti o jọmọ - ANJ-6KP-LV-WIFI, ANJ-3KW-24V-LV-WIFI

Ṣaajuview ANENJI Awọn oluyipada Oorun, Awọn oludari gbigba agbara, ati Katalogi Ọja Batiri
Ṣawari awọn ibiti ANENJI ti awọn oluyipada ti oorun ti o ga julọ, awọn oludari idiyele MPPT oorun, ati awọn batiri LiFePO4. Ṣawari awọn alaye ni pato, awọn ẹya, ati awọn ohun elo fun ibugbe ati lilo adaṣe.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlo Inverter/Charge oorun Hybrid ANENJI 3KVA
Ìwé ìtọ́ni tó péye fún ANENJI 3KVA Hybrid Solar Inverter/Charge, tó bo ìfisílé, iṣẹ́, àwọn ìlànà pàtó, ìṣòro, àti ìṣètò bátírì lithium. Ó ní ìtọ́sọ́nà tó kún rẹ́rẹ́ lórí ìṣètò ètò àti ìpinnu àṣìṣe.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò ANENJI Hybrid Solar Inverter/Charge 3KVA/24VDC 120Vac
Ìwé ìtọ́ni fún àwòṣe ANENJI Hybrid Solar Inverter/Charge 3KVA/24VDC 120Vac, àlàyé lórí fífi sori ẹrọ, iṣẹ́, àwọn ìlànà pàtó, ìṣòro, àti ìṣètò Wi-Fi.
Ṣaajuview Anenji Off-Grid Single-Phase Inverter User Manual (Models 5KC5L1UF, 6KC5L1UF, 7KC5L1UF)
User manual for Anenji Off-Grid Single-Phase Inverters (Models 5KC5L1UF, 6KC5L1UF, 7KC5L1UF). Learn about installation, features, system connection, wiring, communication, interface operation, protection functions, and maintenance for reliable energy solutions.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Ayípadà/Ṣájà Aláwọ̀ ...
Ìwé ìtọ́ni yìí fún àwọn olùlò ní ìlànà tó péye fún ANENJI 4.2KVA àti 5.0KVA Hybrid Solar Inverter/Charge, èyí tó bo ìfisílé, iṣẹ́, àwọn ìlànà pàtó, àti ìṣòro fún ìṣàkóso agbára oòrùn tó gbéṣẹ́.
Ṣaajuview Àwọn Ìlànà Ìmọ̀-ẹ̀rọ ANENJI ANJ-2000W-12V-WiFi Off Grid Hybrid Inverter
Àwọn àlàyé ìmọ̀-ẹ̀rọ tó ṣe kedere fún ANENJI ANJ-2000W-12V-WiFi Off Grid Hybrid Inverter, pẹ̀lú àwọn ẹ̀yà ara rẹ̀, àwọn pàrámítà ìtẹ̀síwájú/ìjáde, àwọn ìlànà bátírì, àti dátà àyíká.