1. Ifihan
The DTL150 is a versatile DC digital electronic load designed for testing battery capacity, power supplies, and other DC equipment. It features a 2.4-inch TFT color screen and supports four primary working modes: Constant Current (CC), Constant Voltage (CV), Constant Power (CP), and Constant Resistance (CR). With a maximum power handling of 150W and a maximum current of 20A, it provides robust testing capabilities. The device incorporates intelligent protection mechanisms and a four-wire connection method for accurate measurements.
2. Awọn ẹya Ọja
- Ifihan: 2.4-inch TFT color screen.
- Awọn ọna Ṣiṣẹ: Ibakan Lọwọlọwọ (CC), Constant Voltage (CV), Constant Power (CP), Constant Resistance (CR).
- Agbara to pọju: 150W power, 20A current.
- Awọn ẹya Idaabobo: Configurable voltage, current, and power over-limit protection. Adjustable stop discharge voltage and discharge time.
- Abojuto iwọn otutu: External NTC sensor support for power supply temperature monitoring.
- Eto Itutu: Integrated alloy silent radiator (20±3dBA) with intelligent temperature control fan.
- Ibi ti ina elekitiriki ti nwa: Requires a 12V1A independent power supply.
- Ọna asopọ: Four-wire connection for precise voltage measurement, backward compatible with two-wire.
- Atẹlu olumulo: Switchable Chinese and English interface.
3. Package Awọn akoonu
- 1 x DTL150 Electronic Load Unit
- 1 x US Plug Power Adapter (AC100-240V)
- 1 x EU Plug Power Adapter (AC100-240V)
4. Ọja Ipariview

This diagram highlights the key components: the four-wire power terminal, NTC sensor interface, working power interface, 2.4-inch TFT display, and set buttons.

A alaye view of the robust bolt-style terminals for secure wiring connections.

A close-up of the control buttons, designed for easy setting and operation.
5. Awọn ilana iṣeto
- Asopọ agbara: Connect the provided 12V1A independent power adapter to the working power interface of the DTL150 unit. Ensure the correct plug type (US or EU) is used for your region.
- Load Connection (Four-wire method for accuracy):
- Identify the four-wire power terminal on the DTL150 (refer to Figure 1).
- Connect the positive (+) and negative (-) voltage sensing wires (typically thinner) from your power source/battery to the V+ and V- terminals on the DTL150.
- Connect the positive (+) and negative (-) current carrying wires (typically thicker) from your power source/battery to the A+ and A- terminals on the DTL150.
- Ensure all connections are secure using the bolt-style terminals (refer to Figure 2).
- Load Connection (Two-wire method - less accurate): If a four-wire connection is not possible, you can short the V+ to A+ and V- to A- terminals and connect your power source/battery using two wires. However, this may introduce voltage drop errors.
- NTC Sensor (Optional): If monitoring the temperature of the power supply, connect an external NTC sensor to the dedicated NTC sensor interface.

Demonstration of connecting the DTL150 to a battery using the 4-wire method for accurate discharge testing.
6. Awọn ilana Iṣiṣẹ
6.1 Ipilẹ isẹ
- Agbara Tan: After connecting the power adapter, the device will power on and display the main interface.
- Ede Ibaramu: The device supports Chinese and English. To switch, navigate to the System Menu (refer to Figure 5, item 19) and select option 01.
- Eto Awọn paramita: Use the multi-buttons (ON/OFF, -, SET, +) to navigate menus and adjust values.
- Awọn ọna Ṣiṣẹ: The DTL150 supports CC (Constant Current), CV (Constant Voltage), CP (Constant Power), and CR (Constant Resistance) modes. Select the desired mode for your test.
6.2 System Menu and Settings

This image displays the system menu options and examples of over-limit protection warnings.
Access the System Menu to configure various settings:
- 01. Chinese English: Switch between Chinese and English display languages.
- 02. Accumulated data reset: Reset accumulated discharge data (Ah, Wh).
- 03. Ofurufutage and current no-load reset: Calibrate voltage and current readings when no load is connected.
- 04. Ofurufutage calibration Ref30V: 00.000V: Fine-tune voltage wiwọn išedede.
- 05. Current calibration Ref3A: 00.000A: Fine-tune current measurement accuracy.
- 06. Screen brightness: 9: Adjust the display brightness (e.g., from 1 to 9).
- 07. Standby time: --S: Set the time before the device enters standby mode.
- 08. Factory reset: Restore all settings to their default factory values.
- 09. Exit: Exit the system menu and return to the main operating interface.
6.3 Awọn Eto Idaabobo
The DTL150 allows setting protection limits to safeguard your power source. When a limit is exceeded, the device will stop discharging and display a warning.
- Voltage Over-limit Protection: Set a maximum voltage threshold. If the input voltage exceeds this value, the device will stop and display "Voltage Overrun > [Preset Voltage]" (e.g., >30.0V).
- Current Over-limit Protection: Set a maximum current threshold. If the discharge current exceeds this value, the device will stop and display "Current Overrun > [Preset Current]" (e.g., >0.5A).
- Power Over-limit Protection: Set a maximum power threshold. If the discharge power exceeds this value, the device will stop and display "Power Overrun > [Preset Power]" (e.g., >30.0W).
- Stop Discharge Voltage: Configure a minimum voltage at which the discharge test should automatically stop to prevent over-discharging batteries.
- Àkókò ìtújáde: Set a maximum duration for the discharge test.
When a test concludes normally, the interface will display "END".
7. Awọn pato
| Paramita | Iye |
|---|---|
| Nọmba awoṣe | DTL150 (Electronic Load) |
| Ifihan | 2.4-inch TFT Awọ iboju |
| Agbara Imujade ti o pọju | 150W |
| Max yosita Lọwọlọwọ | 20A |
| Awọn ọna Ṣiṣẹ | CC (Constant Current), CV (Constant Voltage), CP (Constant Power), CR (Constant Resistance) |
| Ibi ti ina elekitiriki ti nwa | 12V1A (independent adapter) |
| Itutu System | Alloy integrated silent radiator (20±3dBA) with intelligent temperature control |
| Ọna asopọ | 4-wire (backward compatible with 2-wire) |
| Awọn iwọn (L x W x H) | 165 x 95 x 80mm |
| DIY Agbari Ẹka | Itanna |
| Ipilẹṣẹ | Orile-ede China |
8. Itọju
- Ninu: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Afẹfẹ: Ensure the cooling fan and vents are not obstructed to maintain proper airflow and prevent overheating.
- Ibi ipamọ: Store the DTL150 in a dry, cool environment away from direct sunlight and extreme temperatures.
- Adapter agbara: Always use the provided 12V1A power adapter. Using an incorrect adapter may damage the device.
- Awọn imudojuiwọn famuwia: Ṣayẹwo awọn olupese ká website periodically for any available firmware updates (if applicable).
9. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹrọ naa ko ṣiṣẹ. | No power, incorrect adapter, or faulty power connection. |
|
| "Voltage Overrun" warning. | Iwọn titẹ siitage exceeds the set over-limit protection. |
|
| "Current Overrun" warning. | Discharge current exceeds the set over-limit protection. |
|
| "Power Overrun" warning. | Discharge power exceeds the set over-limit protection. |
|
| Aipe voltagàwọn kíkà e/lọ́wọ́lọ́wọ́. | Poor connection, incorrect wiring, or calibration needed. |
|
| Fan is noisy or not working. | Dust accumulation, obstruction, or fan malfunction. |
|
10. Awọn imọran olumulo
- Use 4-wire connection: Always use the 4-wire connection method for the most accurate voltage and current measurements, especially when dealing with higher currents where cable resistance can significantly impact readings.
- Set Protection Limits: Before starting any test, configure the voltage, current, and power over-limit protections, as well as the stop discharge voltage, to prevent damage to the device or the power source being tested.
- Iṣatunṣe: If you suspect measurement inaccuracies, utilize the calibration options in the system menu (Voltage and current no-load reset, Voltage calibration, Current calibration) to ensure precise readings.
- Itutu: Ensure adequate ventilation around the device, especially during high-power discharge tests, to allow the intelligent cooling system to operate effectively.
- Electronic Tutorial: Scan the QR code on the fan center (if available) to access the electronic tutorial for more detailed guidance on specific functions.
11. Atilẹyin ọja ati Support
For warranty information, technical support, or service inquiries, please refer to the seller's contact information or the official product page. Keep your purchase receipt for warranty claims.