1. Ifihan
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your RONIX RC-0200 Air Compressor. Please read this manual thoroughly before operating the unit and keep it for future reference.

Figure 1: RONIX RC-0200 Air Compressor
2. Alaye Aabo
Always follow basic safety precautions to reduce the risk of fire, electric shock, and personal injury when using this product.
- Rii daju pe a gbe konpireso sori iduro, ipele ipele.
- Ma ṣe ṣiṣẹ konpireso ni tutu tabi damp awọn ipo.
- Always wear appropriate personal protective equipment (PPE), such as eye protection.
- Before performing any maintenance, ensure the compressor is unplugged and the tank is fully depressurized.
- Do not modify the pressure settings beyond the recommended limits.
- Pa awọn ọmọde ati awọn oṣiṣẹ ti ko ni aṣẹ mọ kuro ni konpireso ti n ṣiṣẹ.
3. Awọn ẹya Ọja
The RONIX RC-0200 Air Compressor is designed for continuous application with a focus on quiet operation and efficiency.
- Hyper Silent Motor: Engineered for reduced noise during operation.
- Induction Motor: Provides reliable performance for continuous use.
- High Capacity Tank: 200L tank for extended operation.
- Awọn Silinda Meji: Efficient air compression.
- Apẹrẹ to gbe: Equipped with 6-inch casters for easy movement.

Figure 2: Key features of the RC-0200 Air Compressor
4. Eto ati Apejọ
The RC-0200 Air Compressor requires minimal assembly, primarily for attaching the wheels.
- Ṣii silẹ: Carefully remove the compressor from its wooden box packaging. Inspect for any shipping damage.
- Apejọ Kẹkẹ:
- Attach the 4 pieces of 6-inch 20-hole black casters to the designated mounting points on the compressor base.
- Secure each caster using the provided 4MM split pins and 21mm flat pads. Ensure all fasteners are tightened securely.
- Ibi: Gbé compressor náà sí orí ilẹ̀ tó le koko, tó tẹ́jú, ní agbègbè tó ní afẹ́fẹ́ tó dára. Rí i dájú pé àyè tó wà ní àyíká ẹ̀rọ náà wà fún ìṣàn afẹ́fẹ́ àti ìtọ́jú.
- Asopọmọra itanna: Connect the compressor to a grounded 220-240V, 50Hz power outlet. Ensure the power supply matches the compressor's requirements.
- Ṣayẹwo akọkọ: Before first use, ensure all connections are secure and there are no visible leaks or damage.
5. Awọn ilana Iṣiṣẹ
Familiarize yourself with the controls and indicators before operating the compressor.

Figure 3: Detail of controls (pressure gauge, quick connect, pressure switch)
- Agbara Tan: Plug the compressor into a suitable electrical outlet. The pressure switch (often a red button or lever) will typically have ON/OFF markings. Pull the red button up to turn ON the compressor.
- Atunse titẹ: The compressor is equipped with a pressure gauge and a regulator.
- The maximum operating pressure is 0.8MPa (8 bar).
- The safety valve opens at 0.9MPa to prevent over-pressurization.
- The compressor will restart automatically when the pressure drops to 0.6MPa.
- Adjust the output pressure using the regulator knob to suit your pneumatic tool's requirements within the 0.1-0.8MPa use pressure range.
- Connecting Tools: Attach your pneumatic tool to the quick-connect coupler. Ensure a secure connection.
- Isẹ: Once the desired pressure is reached and the tool is connected, you can begin using your pneumatic tools. The compressor will cycle on and off automatically to maintain tank pressure.
- Agbara Pa: Push the red button down to turn OFF the compressor.
- Irẹwẹsi: After use, always depressurize the air tank by opening the drain valve or using an air tool until the pressure gauge reads zero.
6. Itọju
Itọju deedee n ṣe idaniloju pe ki o pẹ to ati pe o le ṣiṣẹ daradara fun compressor afẹfẹ rẹ.
- Ojoojumọ:
- Drain condensation from the air tank. This prevents rust and extends tank life.
- Ṣayẹwo fun eyikeyi awọn ariwo dani tabi awọn gbigbọn.
- Ọsẹ-oṣooṣu:
- Inspect air filter for cleanliness. Clean or replace if necessary.
- Check all fittings and hoses for leaks. Tighten as needed.
- Verify the safety valve operates correctly by briefly pulling its ring.
- Ọdọọdún:
- Ṣayẹwo okun agbara fun ibajẹ.
- Have a qualified technician inspect the compressor for wear and tear.
Warning: Always unplug the compressor and depressurize the tank before performing any maintenance.
7. Laasigbotitusita
This section covers common issues you might encounter with your air compressor.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Compressor ko bẹrẹ | No power; ON/OFF switch in OFF position; Thermal overload activated. | Check power connection; Ensure switch is ON; Allow motor to cool and reset thermal overload. |
| Compressor nṣiṣẹ lemọlemọ tabi nigbagbogbo | Air leak in tank or connections; Excessive air consumption; Pressure switch malfunction. | Check for leaks using soapy water; Reduce air tool usage; Consult service technician. |
| Ìjáde titẹ afẹfẹ kekere | Air leaks; Clogged air filter; Regulator set too low. | Check for leaks; Clean/replace air filter; Adjust regulator to desired pressure. |
| Ariwo pupọ tabi gbigbọn | Loose components; Worn motor bearings; Unstable surface. | Tighten all fasteners; Consult service technician; Place on a stable, level surface. |
8. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | RC-0200 |
| Voltage | 220-240V |
| Agbara | 2200W |
| Agbara ojò | 200L |
| Igbohunsafẹfẹ | 50Hz |
| Iyara | 1000 RPM |
| Ifijiṣẹ afẹfẹ | 370 L/min |
| Iwọn titẹ to pọju | MP0.8 8 (igi XNUMX) |
| Ailewu àtọwọdá šiši | 0.9 MPa |
| Tun Titẹ bẹrẹ | 0.6 MPa |
| Lo Ibiti Ipa | 0.1-0.8 MPa |
| Ìwúwo (GW) | 120 kg |
| Iwọn (L*W*H) | 140 * 50 * 98 cm |
| Iṣeto ni | Adaduro |
| Orisun agbara | Afẹfẹ |
| Pa ẹnu mọ́ | Bẹẹni |
| Awọn eroja mojuto | Enjini |
| Pese Ni | Apoti onigi |
| Pẹlu | 6 inch 20 hole black casters 4pcs, 4MM split pin 4pcs, 21mm flat pad 4pcs |
9. Atilẹyin ọja ati Support
The RONIX RC-0200 Air Compressor comes with a 1-year warranty for core components. For any issues or support, please contact your seller or an authorized service center.
The manufacturer is responsible for the supplied product within its usage life.
10. Awọn imọran olumulo
- Always ensure the air hose and connections are free from kinks or damage to maintain optimal airflow and prevent leaks.
- For best performance and to prolong the life of your pneumatic tools, use an inline air filter/regulator/lubricator (FRL unit) if your tools require lubrication.
- Regularly check the pressure gauge for accurate readings.
- Tọ́jú compressor náà sí ibi tí ó gbẹ tí ó sì mọ́ nígbà tí a kò bá lò ó.
11. Awọn ibeere Nigbagbogbo (FAQ)

Figure 4: Common questions and answers
- Q: What about the after-sales service?
- A: Ile-iṣẹ wa ni o ni iduro fun ọja ti a pese lakoko igbesi aye lilo rẹ.
- Q: Can you help me design or modify the products as we request?
- A: We develop new products with your requested quality through our R&D department. Our professional design team can assist if the Minimum Order Quantity (MOQ) is met.
- Q: What about the samples?
- A: We can supply samples. A sample fee will be charged and returned after the order is confirmed. The customer is responsible for the shipping fee when a specific delivery method is required.