SINOTIMER CN101S

Ìwé ìtọ́ni fún yíyípadà aago LCD oni-nọmba SINOTIMER CN101S

Model: CN101S

1. Ifihan

The SINOTIMER CN101S is a reliable 1-second interval digital LCD timer switch designed for automatic control of various electrical equipment. This programmable time relay allows you to set precise ON/OFF schedules over a 7-day weekly cycle, with a minimum interval of 1 second. It is ideal for applications such as controlling streetlights, neon signs, lamps, water heaters, air conditioners, billboards, electric cookers, boosters, sprayers, bottlers, preheaters, agriculture facilities, and broadcasting equipment.

Equipped with a built-in battery, the CN101S retains its programmed settings even during power failures, ensuring continuous operation. Its design features low power consumption, a high-accuracy CMOS chip, and strong anti-jamming capabilities, making it simple and easy to set up and use.

2. Key Awọn ẹya ara ẹrọ

  • Iṣakoso ti a le ṣeto: 24 hours / 7 days a week programming with 1-second interval.
  • Agbara giga: Rated for 3500 Watts / 16 Amps.
  • Afẹyinti Iranti: 1.2V built-in battery saves programs during power outages.
  • Yiye: Auto time error correction of +/- 30 seconds weekly.
  • Input/Ojade Voltage: 200-250VAC, 50/60Hz.
  • Iṣetojade O wu: 1 Normally Open (NO) contact.
  • Ohun elo: Durable ABS + electronic components.
  • Apẹrẹ Iwapọ: Easy to integrate into various setups.

3. Imọ ni pato

ParamitaIye
AwoṣeCN101S
Iṣagbewọle Voltage200-250VAC, 50/60Hz
O wujade Voltage200-250VAC
Max Fifuye lọwọlọwọ16 Amps
Max Fifuye Power3500 Wattis
Eto siseto24 hours / 7 days weekly
Aarin ti o kere julọ1 Ikeji
Time Error Correction+/- 30 seconds weekly (Auto)
Afẹyinti Iranti1.2V Built-in Battery
Ohun eloABS + Itanna irinše
Awọn iwọn (L x W x H)7.0 cm x 7.0 cm x 4.0 cm

4. Eto ati Wiring

Akiyesi Aabo pataki: Installation should be performed by a qualified electrician or knowledgeable individual. Ensure power is disconnected before attempting any wiring.

4.1 Wiring aworan atọka

Refer to the diagram below for proper wiring connections. The timer features 5 terminals on the back for input power and load connection.

Pada view of SINOTIMER CN101S showing terminals 1 to 5 with labels: 1-LINE INPUT, 2-NEUT INPUT, 3-NEUT POWER OUTPUT, 4-LOAD POWER OUTPUT, 5-LOAD POWER OUTPUT.
olusin 1: Ẹyìn view with wiring terminals and specifications.
  • Terminal 1 (LINE INPUT): Connect the Live (L) wire of your 200-250VAC, 50/60Hz power supply.
  • Terminal 2 (NEUT INPUT): Connect the Neutral (N) wire of your 200-250VAC, 50/60Hz power supply.
  • Terminal 3 (NEUT POWER OUTPUT): Connect the Neutral (N) wire of your electrical load to this terminal. This provides the neutral path for the load.
  • Terminal 4 (LOAD POWER OUTPUT): Connect the Live (L) wire of your electrical load to this terminal. This is the switched Live output (Normally Open contact) that the timer will control.
  • Terminal 5 (LOAD POWER OUTPUT): This terminal is also labeled "LOAD". Given the specification of "1NO" (one Normally Open contact), Terminal 4 is the primary switched output. Terminal 5 may be an alternative connection point for the switched load or for specific dual-load configurations not typically used with a single NO relay. For standard operation, use Terminal 4 for the switched live to your load.

Rii daju pe gbogbo awọn asopọ wa ni aabo ati idabobo.

4.2 Initial Power-Up and Display Overview

Once wired, apply power. The LCD display will illuminate. If the display is blank or dim, allow the internal battery to charge for a few minutes. The built-in 1.2V battery ensures that your programmed settings are retained even if the main power is interrupted.

Iwaju view of SINOTIMER CN101S showing LCD display and control buttons: MANUAL, P, D+, H+, M+, R, and a clock icon button.
Figure 2: Front panel with LCD display and control buttons.

Panel iwaju pẹlu:

  • Ifihan LCD: Shows current time, day, ON/OFF status, and programming modes.
  • Bọtini Afọwọṣe: For manual override of the timer's output.
  • Bọ́tìnì P (Ètò): Enters and navigates programming mode.
  • Bọ́tìnì D+ (Ọjọ́): Adjusts the day of the week or selects days in program mode.
  • Bọ́tìnì H+ (Wákàtí): Adjusts the hour.
  • Bọ́tìnì M+ (Ìṣẹ́jú): Adjusts the minute.
  • Clock Icon Button: Used in conjunction with D+, H+, M+ to set the current time.
  • Bọ́tìnì R (Àtúnṣe): Resets the timer to factory defaults (clears all programs and current time).

5. Awọn ilana Iṣiṣẹ

5.1 Ṣíṣeto Àkókò àti Ọjọ́ Lọ́wọ́lọ́wọ́

  1. Tẹ mọlẹ Aami Aago bọtini.
  2. Nigba dani awọn Aami Aago bọtini, tẹ D+ lati ṣeto awọn ti isiyi ọjọ ti awọn ọsẹ.
  3. Nigba dani awọn Aami Aago bọtini, tẹ H+ lati ṣeto awọn ti isiyi wakati.
  4. Nigba dani awọn Aami Aago bọtini, tẹ M+ lati ṣeto awọn ti isiyi iseju.
  5. Tu silẹ Aami Aago button. The current time and day are now set.

5.2 Àwọn Ìṣètò Títẹ̀/Pàṣẹ Síṣe Ìṣètò

The CN101S allows for multiple ON/OFF programs. Follow these steps to set your desired schedules:

  1. Tẹ awọn P (Program) bọ́tìnì lẹ́ẹ̀kan láti wọ ipò ètò ètò. Ìfihàn náà yóò fi "1 ON" hàn.
  2. Tẹ D+ to select the day(s) for this program. You can choose individual days, weekdays, weekends, or all 7 days.
  3. Tẹ H+ láti ṣètò wákàtí ON tí a fẹ́.
  4. Tẹ M+ láti ṣètò ìṣẹ́jú ON tí a fẹ́.
  5. Tẹ P (Program) button again. The display will show "1 OFF".
  6. Tẹ D+ to select the day(s) for this OFF program (usually the same as the ON program).
  7. Tẹ H+ to set the desired OFF hour.
  8. Tẹ M+ to set the desired OFF minute.
  9. To set additional programs, press P (Program) again to cycle through "2 ON", "2 OFF", and so on. Repeat steps 2-8 for each program.
  10. Ni kete ti gbogbo awọn eto ba ti ṣeto, tẹ bọtini naa Aami Aago bọtini lati jade kuro ni ipo siseto ki o pada si ifihan akoko lọwọlọwọ.

The timer supports 1-second intervals, meaning you can set very precise ON/OFF durations. If a program is not needed, simply skip setting its ON/OFF times, or ensure the ON and OFF times are identical to effectively disable it.

5.3 Afowoyi danu

Awọn Afọwọṣe button allows you to temporarily override the programmed schedule. Pressing this button will cycle through different modes:

  • LATI: Ìjáde náà ń ṣiṣẹ́ lórí àwọn ètò nígbà gbogbo, láìfiyèsí àwọn ètò náà.
  • LATIO: The timer operates according to the programmed schedules.
  • PA: Ìjáde náà ń pa nígbà gbogbo, láìka àwọn ètò sí.

Select "AUTO" for the timer to follow your programmed schedules.

5.4 Ṣíṣe àtúnṣe Aago náà

To clear all programs and reset the current time to factory defaults, press the small R (Àtúnṣe) button using a pointed object (like a pen tip). After resetting, you will need to set the current time and reprogram all schedules.

6. Itọju

  • Ninu: Wipe the timer's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Batiri: The CN101S has a built-in 1.2V battery for memory backup. This battery is not user-replaceable. If the timer consistently loses settings after power outages, the battery may need servicing by a professional.
  • Ayika: Ensure the timer is installed in a dry environment, away from direct sunlight, extreme temperatures, and corrosive substances.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Ifihan ti ṣofo tabi baibai.No power supply or internal battery discharged.Check power connections. Allow timer to charge for a few minutes after initial power-up.
Àkókò aago kò máa yípadà/pa gẹ́gẹ́ bí a ti ṣètò rẹ̀.Incorrect program settings, manual override active, or incorrect current time.
  • Verify current time and day are set correctly.
  • Check program settings (ON/OFF times, days).
  • Ensure the timer is in "AUTO" mode using the MANUAL button.
  • Verify wiring connections are correct and secure.
Programs are lost after a power outage.Batiri afẹyinti inu ti pari tabi bajẹ.The battery is not user-replaceable. If this issue persists, consider professional servicing or replacement.
Awọn bọtini ko dahun.Àṣìṣe ìgbà díẹ̀ tàbí ìbàjẹ́ ara.Try pressing the R (Reset) button. If unresponsive, disconnect power for a few minutes and reconnect. If problem persists, contact support.

8. Awọn imọran olumulo

  • For critical applications, always double-check your programmed schedules after setting them.
  • Consider using the manual override function for temporary changes without altering your main programs.
  • When setting programs, ensure the ON time is before the OFF time within a 24-hour cycle, or that the OFF time is on the subsequent day if the cycle spans midnight.

9. Atilẹyin ọja ati Support