1. Ifihan
The DATOUBOSS 6200W Pure Sine Wave Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support with a portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage da lori orisirisi awọn ohun elo.
1.1 Key Awọn ẹya ara ẹrọ
- Pure sine wave output for stable power supply to sensitive electronics.
- Configurable igbewọle voltagibiti o wa fun awọn ohun elo ile ati awọn kọnputa ti ara ẹni nipasẹ eto LCD.
- Agbara gbigba agbara batiri ti a le ṣatunṣe da lori awọn ohun elo nipasẹ eto LCD.
- Aṣeyọri AC/Solar Charger ti a le ṣatunṣe nipasẹ eto LCD.
- Ni ibamu pẹlu mains voltage tabi monomono agbara.
- Tun bẹrẹ laifọwọyi lakoko ti AC n bọlọwọ pada.
- Àpọ̀jù ẹrù, ìgbóná ju bó ṣe yẹ lọ, àti ààbò ìyípo kúkúrú.
- Apẹrẹ ṣaja batiri Smart fun iṣẹ batiri iṣapeye.
- Ibẹrẹ iṣẹ tutu.
- Built-in Intelligent MPPT System for maximizing solar energy conversion efficiency.
- Compatible with 48V Lead-Acid and Lithium Batteries, and can run batteryless.
- Supports parallel connection for enhanced power output and scalability.
- BMS communication for remote monitoring and control.
1.2 Ipilẹ System Architecture
The inverter is designed to integrate with photovoltaic modules, generators, and batteries to form a complete operating system. It can power various electrical devices in your home or office, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

2. Awọn ilana aabo
IKILO: Apa yii ni aabo pataki ati awọn ilana iṣiṣẹ ninu. Ka ki o si tọju iwe afọwọkọ yii fun itọkasi ọjọ iwaju.
- Ṣaaju lilo ẹyọkan, ka gbogbo awọn ilana ati awọn ami akiyesi lori ẹyọkan, awọn batiri, ati gbogbo awọn abala ti o yẹ fun afọwọṣe yii.
- IKIRA: Láti dín ewu ìpalára kù, gba agbára lórí àwọn bátìrì oní-asídì oní-jinlẹ̀ nìkan. Àwọn bátìrì mìíràn lè bú gbàù, kí wọ́n sì fa ìpalára àti ìbàjẹ́ ara ẹni.
- Maṣe ṣajọpọ ẹyọ naa. Mu lọ si ile-iṣẹ iṣẹ ti o ni oye nigbati iṣẹ tabi atunṣe nilo. Ipejọpọ ti ko tọ le ja si eewu ti mọnamọna tabi ina.
- Lati dinku eewu ina mọnamọna, ge asopọ gbogbo awọn wirin ṣaaju ṣiṣe eyikeyi itọju tabi mimọ. Pa ẹyọ kuro kii yoo dinku eewu yii.
- IKIRA: Oṣiṣẹ oṣiṣẹ nikan le fi ẹrọ yii sori ẹrọ pẹlu batiri.
- MASE gba agbara si batiri tio tutunini.
- Fun iṣẹ ṣiṣe ti o dara julọ, tẹle awọn alaye pataki lati yan iwọn okun waya ti o yẹ.
- Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu awọn irinṣẹ irin lori tabi ni ayika awọn batiri. Ewu ti o pọju wa lati ju ohun elo kan silẹ si sipaki tabi awọn batiri Circuit kukuru tabi awọn ẹya itanna miiran ati pe o le fa bugbamu.
- Strictly follow installation procedures when connecting or disconnecting AC or DC terminals.
- A pese fiusi 150A gẹ́gẹ́ bí ààbò tó pọ̀jù fún ìpèsè batiri.
- Awọn itọnisọna ipile: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- MASE fa awọn iyipo kukuru ti AC ati awọn iyipo kukuru ti DC n wọle. MA ṢE sopọ mọ awọn mains nigbati DC ba n wọle awọn iyipo kukuru.
- IKILO: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, send this inverter/charger back to a local dealer or service center for maintenance.
3. Ọja Ipariview
3.1 Product Dimensions and Key Specifications

3.2 Detailed Parameters (Model DT-4862L)

3.3 LCD Display and Back Panel Overview

The front panel features an LCD display, status indicators (AC/INV, CHG, FAULT), and function keys (ESC, UP, DOWN, ENTER) for operation and monitoring. The back panel provides various connection ports including AC Input, AC Output, RS232, BMS/RS485, Dry Contact, Parallel connection, Battery Input, Power ON/OFF Switch, PV Input, Input Breaker, Fan, Battery Terminals, Solar Panel Input, AC Main/Second Output, and Output ground wire.
4. fifi sori
4.1 Unpacking ati ayewo
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain the inverter unit (x1) and the user manual (x1).
4.2 Ìmúrasílẹ̀ àti Ìfilọ́lẹ̀
Before connecting, remove the bottom cover by removing two screws. When selecting a mounting location, consider the following:
- Maṣe gbe ẹrọ oluyipada sori awọn ohun elo ikole flammable.
- Òke lori kan ri to dada.
- Fi inverter yii sori ẹrọ ni ipele oju fun irọrun kika ifihan LCD.
- Allow clearances of approximately 20 cm to the sides and 50 cm above and below the unit for proper air circulation and heat dissipation.
- Iwọn otutu ayika yẹ ki o wa laarin 10°C ati 50°C fun iṣẹ ṣiṣe to dara julọ.
- Fi sori ẹrọ ni inaro.
- Rí i dájú pé ààyè tó tó láti yọ àwọn wáyà kúrò.
WARNING: Suitable for mounting on concrete or other non-combustible surfaces only.
Install the unit by screwing three screws: use M6*80mm expansion bolts for points 1 and 2, and M4 or M5 for point 3.
4.3 batiri Asopọ
IKIRA:
- For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
- Gbogbo onirin gbọdọ wa ni ṣiṣe nipasẹ oṣiṣẹ oṣiṣẹ.
- Use appropriate cable for battery connection to reduce risk of injury.
Refer to the table below for recommended battery cable and terminal sizes. Assemble battery ring terminals, insert battery wires flatly into inverter connectors, and ensure bolts are tightened to 2 Nm. Verify correct polarity at both the battery and inverter/charger.
| Awoṣe | Aṣoju Ampigba | Agbara Batiri | Waya Iwon | Ring Terminal Dimensions (D/L mm) | Torque Iye |
|---|---|---|---|---|---|
| 2KVA | 88A | 100AH | 1*6AWG / 2*10AWG | 6.4/33.2 / 6.4/23.8 | 2 ~ 3 Nm |
| 3KVA | 132A | 200AH | 1*4AWG / 2*8AWG | 6.4/33.2 / 6.4/29.2 | 2 ~ 3 Nm |
| 3.6KVA | 165A | 200AH | 2*4AWG | 8.4/33.2 | 5Nm |
| 5KVA | 109A | 200AH | 1*2AWG / 2*6AWG | 6.4/39.2 / 6.4/33.2 | 2 ~ 3 Nm |
| 5.5KVA | 121A | 200AH | 1*2AWG / 2*6AWG | 6.4/39.2 / 6.4/33.2 | 2 ~ 3 Nm |
| 6.2KVA | 124A | 200AH | 1*2AWG / 2*4KWG | 8.4/39.2 / 8.4/33.2 | 5Nm |
| 8KVA | 183.2A | 250AH | 1*2/0AWG | 8.4/51 | 5Nm |
| 11KVA | 228A | 250AH | 1*3/0AWG | 8.4/54 | 5Nm |
IKILO: Rii daju pe ipari ti gbogbo awọn kebulu batiri jẹ kanna. Tabi ki, nibẹ ni yio je voltage difference between inverters and batteries, causing parallel inverters not to work.
4.4 AC Input / o wu Asopọ
IKIRA:
- Install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be disconnected during maintenance and is protected from over-current. Recommended breaker specs: 32A for 3KW, 50A for 5KW.
- Do not mis-connect input and output connectors. There are two terminal blocks with "IN" and "OUT" markings.
- Gbogbo onirin gbọdọ wa ni ṣiṣe nipasẹ oṣiṣẹ oṣiṣẹ.
Refer to the table below for suggested AC wire requirements. Before making connections, open the DC protector or disconnector. Remove 10mm of insulation from conductors and shorten phase L and neutral conductor N by 3mm.
| Awoṣe | Iwọn | Torque Iye |
|---|---|---|
| 2KVA | 14AWG | 0.8 ~ 1.0Nm |
| 3KVA | 12AWG | 1.2 ~ 1.6Nm |
| 3.6KVA | 12AWG | 1.2 ~ 1.6Nm |
| 5KVA | 10AWG | 1.4 ~ 1.6Nm |
| 5.5KVA | 10AWG | 1.4 ~ 1.6Nm |
| 6.2KVA | 10AWG | 1.4 ~ 1.6Nm |
| 8KVA | 8AWG | 1.4 ~ 1.6Nm |
| 11KVA | 8AWG | 1.4 ~ 1.6Nm |
WARNING: Be sure all output N wires of each inverter must be connected all the time. Otherwise, it will cause inverter fault in error code #72.
4.5 PV Asopọ
IKIRA:
- Kí o tó so mọ́ àwọn modulu PV, fi ẹ̀rọ fifọ DC tó yàtọ̀ síra sí àwọn modulu inverter àti PV.
- Gbogbo onirin gbọdọ wa ni ṣiṣe nipasẹ oṣiṣẹ oṣiṣẹ.
- Use appropriate cable for PV module connection.
Refer to the table below for suggested PV wire requirements. When choosing PV modules, ensure the open circuit voltage (Voc) kò ju vol iyipo ṣiṣi PV ti o pọ julọ lọtage ti awọn ẹrọ oluyipada. Awọn ti o pọju ipese voltage yẹ ki o sunmọ vol wiwọle PV ti o dara julọtage range for best performance. If one PV module cannot meet this requirement, connect multiple PV modules in series.
| Aṣoju Ampigba | Iwọn | Torque Iye |
|---|---|---|
| 30A | 12AWG | 1.4 ~ 1.6Nm |
4.6 ik Apejọ
After connecting all wirings, put the bottom cover back by screwing the two screws. Then, put the wire cover back to the unit.
4.7 Asopọ ibaraẹnisọrọ
The inverter supports communication with a PC, Wi-Fi cloud, and GPRS cloud. For detailed instructions on setting up monitoring software or apps, refer to the specific guidelines provided with the communication modules (e.g., "Wi-Fi Plug Quick Installation Guideline" or "GPRS RTU Quick Installation Guideline").

5. Isẹ
5.1 Agbara Tan / Pa
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the button of the case) to turn on the unit.
5.1.1 Awọn Igbesẹ lati Bẹrẹ
- So batiri naa pọ (volt)tage needs to be beyond 23V) or AC (AC needs to confirm the suitable input range depending on the output mode).
- Agbara akọkọ lori: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, the panel will display AC mode after a period, indicating successful startup.
- Bọ batiri: Connect to battery, press the power-on button. The system will automatically turn on. After a period, the panel will display battery mode, indicating successful startup.
5.1.2 Àwọn Ìgbésẹ̀ Títìpa
When the system is in battery mode or AC mode output, press the switch again to turn off the unit.
5.2 Isẹ ati Ifihan Panel
The operation and display panel on the front of the inverter includes an LCD display, three LED indicators (AC/INV, CHG, FAULT), and four function keys (ESC, UP, DOWN, ENTER). These indicate the operating status and input/output power information.

| LED Atọka | Ipo | Ifiranṣẹ |
|---|---|---|
| AC/INV | Alawọ Ri to Lori | Ijade jẹ agbara nipasẹ IwUlO ni Ipo Laini. |
| Imọlẹ Green | Ijade jẹ agbara nipasẹ batiri tabi PV ni ipo batiri. | |
| CHG | Alawọ Ri to Lori | Batiri ti gba agbara ni kikun. |
| Imọlẹ Green | Batiri n gba agbara. | |
| ÀÌṢE | Red Ri to Lori | Aṣiṣe waye ninu oluyipada. |
| Imọlẹ pupa | Ipo ikilọ waye ninu oluyipada. |
| Bọtini iṣẹ | Apejuwe |
|---|---|
| ESC | Lati jade ni ipo eto. |
| UP | Láti lọ sí àṣàyàn tí ó ti kọjá. |
| SILE | Láti lọ sí àṣàyàn tó tẹ̀lé. |
| WOLE | Láti jẹ́rìí sí yíyàn náà ní ipò ìṣètò tàbí láti tẹ ipò ìṣètò. |
5.3 LCD Eto ati Ifihan
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN buttons to select programs and ENTER to confirm. The LCD display cycles through various information such as input voltage, frequency, PV voltage, gbigba agbara lọwọlọwọ, batiri voltage, iwọn didun ti o wujadetage, o wu igbohunsafẹfẹ, fifuye ogoruntage, load in Watt/VA, DC discharging current, and firmware versions.
5.4 Ìbáramu Batiri
The inverter includes a battery equalization function to reverse the buildup of negative chemical effects like stratification and to remove sulfate crystals. It is recommended to equalize batteries periodically.
5.4.1 Nigbati lati dogba
The controller will enter the Equalize stage when the setting equalization interval is reached or when equalization is actively initiated. The battery will remain in this stage titi ti a fi de akoko ti a ṣeto ti o dọgba.
5.4.2 Ṣe àfikún àkókò gbígbà agbára àti àkókò ìparí
During equalization, the controller charges the battery until it reaches the equalization voltage. Ti o ba ti batiri voltage does not reach the equalization voltage within the set equalized time, the controller will extend the charging time until the voltage is achieved. If it still doesn't reach the voltage after the timeout, equalization will stop and return to float stage.
6. Itọju
Regular maintenance ensures the longevity and optimal performance of your DATOUBOSS Hybrid Solar Inverter. Always disconnect all power sources (AC, DC, and battery) before performing any maintenance.
- Ninu: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a soft, dry cloth for cleaning the exterior.
- Ṣayẹwo awọn isopọ: Periodically inspect all electrical connections (battery, AC input/output, PV input, communication ports) for tightness and corrosion. Tighten any loose connections and clean any corrosion.
- Ayewo Batiri: Check battery terminals for corrosion and ensure battery cables are in good condition. Monitor battery voltage and performance regularly.
- Awọn imudojuiwọn famuwia: Ṣayẹwo awọn olupese ká website or contact support for any available firmware updates to ensure optimal performance and access to new features.
- Ṣayẹwo Ayika: Ensure the inverter is operating within the recommended temperature and humidity ranges.
WARNING: Only qualified personnel should perform maintenance that involves opening the unit or working with internal components.
7. Laasigbotitusita
This section provides guidance for common issues, fault codes, and warning messages. For persistent problems, contact qualified service personnel.
7.1 Fault Codes and Solutions
When the inverter enters fault mode, the red LED light is always on, and the LCD displays a fault code. Refer to the table below for explanations and solutions.
| Aṣiṣe koodu | Ìṣẹ̀lẹ̀ Àṣìṣe / Ohun Tó Ṣeé Ṣe | Kin ki nse |
|---|---|---|
| 01 | Afẹfẹ ti wa ni titiipa nigbati ẹrọ oluyipada wa ni pipa. | Contact repair center for fan replacement. |
| 02 | Lori otutu tabi NTC ko ni asopọ daradara. | Check for proper ventilation and ambient temperature. |
| 03 | Batiri voltage ga ju. | Check battery charging settings. |
| 04 | Batiri voltage kere ju. | Tun gba agbara pada tabi ropo batiri. |
| 05 | Output short circuited or over temperature detected by internal converter components. | Ṣàyẹ̀wò àwọn wáyà, yọ ẹrù tí kò dára kúrò. |
| 06 | O wu voltage ga ju. | Contact repair center. |
| 07 | Apọju akoko jade. | Din awọn ti sopọ fifuye. |
| 08 | Voltage ga ju. | Contact repair center. |
| 09 | Bosi rirọ ibere kuna. | Contact repair center. |
| 51 | Lori awọn sisan tabi ilosoke. | Tun ẹrọ naa bẹrẹ. Ti aṣiṣe naa ba tẹsiwaju, pada si ile-iṣẹ atunṣe. |
| 52 | Voltage kere ju. | Tun ẹrọ naa bẹrẹ. Ti aṣiṣe naa ba tẹsiwaju, pada si ile-iṣẹ atunṣe. |
| 53 | Ibẹrẹ rirọ Inverter kuna. | Tun ẹrọ naa bẹrẹ. Ti aṣiṣe naa ba tẹsiwaju, pada si ile-iṣẹ atunṣe. |
| 55 | Lori DC voltage ninu AC o wu jade. | Contact repair center. |
| 57 | Sensọ lọwọlọwọ kuna. | Contact repair center. |
| 58 | O wu voltage kere ju. | Tun ẹrọ naa bẹrẹ. Ti aṣiṣe naa ba tẹsiwaju, pada si ile-iṣẹ atunṣe. |
| 59 | PV voltage ti kọja opin. | Din awọn nọmba ti PV modulu ni jara. |
7.2 Ikilọ Awọn apejuwe
When a warning occurs, the red LED flashes, and the LCD displays an alarm code. The inverter does not enter failure mode during a warning. Refer to the table below for warning events and audible alarms.
| Koodu Ikilọ | Iṣẹlẹ Ikilọ | Itaniji Ngbohun |
|---|---|---|
| 01 | Afẹfẹ ti wa ni titiipa nigbati ẹrọ oluyipada wa ni titan. | Bee ni igba mẹta ni gbogbo iṣẹju-aaya. |
| 02 | Lori iwọn otutu. | Ko si. |
| 03 | Batiri ti gba agbara ju. | Bee ni ẹẹkan ni iṣẹju-aaya. |
| 04 | Batiri kekere. | Bee ni ẹẹkan ni iṣẹju-aaya. |
| 07 | Apọju. | Bee lẹẹkan ni gbogbo iṣẹju 0.5. |
| 10 | Iwajade agbara ti njade. | Bee lẹẹmeji ni gbogbo iṣẹju 3. |
| 15 | Agbara PV jẹ kekere. | Bee lẹẹmeji ni gbogbo iṣẹju 3. |
| 16 | Ipese AC giga (>280VAC) lakoko ibẹrẹ BUS rirọ. | Ko si. |
| EQ | Ìdọ́gba bátìrì. | Ko si. |
| 6P | Batiri naa ko sopọ. | Ko si. |
7.3 Code Reference for Information
Related information codes are displayed on the LCD screen. These codes provide status updates rather than indicating a fault or warning.
| Koodu | Apejuwe |
|---|---|
| 60 | If battery status is not allowed to charge and discharge after communication between inverter and battery is successful, it will show code 60 to stop charging and discharging battery. |
| 61 | Communication lost. After 10 minutes, inverter will stop charging and discharging to lithium battery. |
| 69 | If battery status is not allowed to charge after communication, it will show code 69 to stop charging battery. |
| 70 | If battery status must charge after communication, it will show code 70 to charge battery. |
| 71 | If battery status is not allowed to discharge after communication, it will show code 71 to stop discharge battery. |
8. Awọn pato
This section provides detailed technical specifications for the DATOUBOSS 6200W Pure Sine Wave Hybrid Solar Inverter.
8.1 Gbogbogbo Awọn alaye
| Iwa | Iye |
|---|---|
| Orukọ Brand | DATOUBOSS |
| Awoṣe ọja | DT-4862/DT-4862L |
| Ipilẹṣẹ | Orile-ede China |
| Ijẹrisi | CE, FCC, RoHS, pse, weee |
| Ti won won Agbara | 6200W |
| Agbara ti o ga julọ | 12400W |
| Ti won won Agbara | 6200W |
| Imudara Iyipada | 0.9 |
| Fọọmu igbi | Wave Sine Sure |
| Àkókò Ìgbésẹ̀ (a lè ṣàtúnṣe) | Àwọn Kọ̀mpútà (Ìpo UPS) 10ms, Ẹ̀rọ (Ìpo APL) 20ms |
| Ibudo Ibaraẹnisọrọ | Lithium Battery BMS Communication Card WifiCard, Dry Contact |
| RS232 | Oṣuwọn Baud 2400 |
| Awọn iwọn otutu ti nṣiṣẹ | -10 ~ 50°C |
| Ọriniinitutu | 20% ~ 95% (ti kii ṣe itọlẹ) |
| Ariwo | <50db |
8.2 Input/Output Specifications
| Iwa | Iye |
|---|---|
| Awọn orisun igbewọle | L+N+PE |
| Oṣuwọn Input Voltage | 220/230 / 240VAC |
| Voltage Ibiti | 90-280VAC±3V (Ipo APL), 170-280VAC±3V (Ipo UPS) |
| Iṣagbewọle Voltage (PV) | 20V-109V |
| O wujade Voltage | AC 220V±10% / 220/230/240VAC±5% |
| Igbohunsafẹfẹ Ijade | 50Hz/60Hz (Auto Adaptive) / 50Hz/60Hz±0.1% |
8.3 PV Charging Mode Specifications
| Iwa | Iye |
|---|---|
| MAX.PV Input Power | 6200W |
| MPPT Àtòjọ Ibiti | 120 ~ 500Vdc |
| Best Voltage | 300 ~ 400Vdc |
| MAX.PV Input Voltage | 500Vdc |
| MAX.PV Gbigba agbara lọwọlọwọ | 100A |
| MAX.AC Gbigba agbara lọwọlọwọ | 80A |
| Lílo agbára gíga jùlọ | 120A |

9. Awọn imọran olumulo
- Isopọ ti o jọra: The inverter supports parallel connection with other inverters of the same model. Ensure you use the appropriate parallel board and communication cables as described in Appendix I of the full user manual. This allows for increased power output and system scalability.
- Ibamu Batiri: This inverter is compatible with both 48V Lead-Acid and Lithium batteries. It also features a batteryless mode, allowing it to power loads directly from the PV array or AC grid without a connected battery.
- Mu Batiri Lithium ṣiṣẹ: For dormant Li-ion batteries, the inverter has a dual activation function where either mains or photovoltaic power supply access can trigger activation.
- Optimizing Energy Use: Utilize the four charging modes and three discharge modes to maximize energy use and reduce electricity bills. Refer to the LCD settings for configuring these modes.
- Afọwọṣe PDF: For a complete and detailed guide, please refer to the official user manual PDF available at: DATOUBOSS 6200W Inverter User Manual (PDF).
10. Atilẹyin ọja ati Support
DATOUBOSS products are designed for reliability and performance. For warranty information, including terms, conditions, and duration, please refer to the documentation provided with your purchase or contact your seller directly. Keep your proof of purchase for warranty claims.
10.1 Imọ Support
If you encounter any issues or require technical assistance, please contact the DATOUBOSS FlagShip Store or your authorized dealer. Provide your product model (DT-4862/DT-4862L) and a detailed description of the problem to facilitate support.
Note: Only qualified service persons are authorized to perform repairs on this device.