1. Ifihan ati Loriview
The KAIWEETS HT118A is a 6000-count auto-ranging digital multimeter designed for accurate and reliable measurement of various electrical parameters. This advanced tester is suitable for diagnosing automotive, industrial, and household electrical issues. It features True RMS (TRMS) for precise readings of non-sinusoidal waveforms, non-contact voltage (NCV) detection, and a live wire function for enhanced safety.

Figure 1: KAIWEETS HT118A Digital Multimeter
2. Alaye Aabo
Always adhere to safety precautions when using the multimeter to prevent electric shock or damage to the device. This multimeter is IEC Rated CAT III 1000V and CAT IV 600V, CE, and RoHS certified. It incorporates anti-burn protection with double ceramic fuses and a thermistor protection circuit. High Voltage Protection is active on all ranges, and the unit is double insulated.
- Always inspect the multimeter and test leads for any damage before use.
- Do not use the multimeter if it appears damaged or if the test leads are frayed.
- Rí i dájú pé a yan iṣẹ́ àti ìwọ̀n tó yẹ kí a tó ṣe àwọn ìwọ̀n.
- Má ṣe kọjá iye ìtẹ̀síwájú tó pọ̀ jùlọ fún gbogbo ìwọ̀n.
- Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu voltagÀwọn wọ̀nyí lókè 30V AC RMS, 42V tente oke, tàbí 60V DC, nítorí pé wọ́n ń fa ewu ìjayà.
- Máa yọ agbára kúrò nínú ẹ̀rọ náà kí o tó wọn resistance, capacitance, tàbí continuity.
- Rọpo awọn batiri ni kiakia nigbati atọka batiri kekere ba han.
3. Package Awọn akoonu
Jẹrisi pe gbogbo awọn ohun kan wa ninu package:

Figure 2: KAIWEETS HT118A Package Contents
- 1 x KAIWEETS HT118A Digital Multimeter
- Àwọn Ìdánwò 2 x (Pupa àti Dúdú)
- 1 x Itọsọna olumulo
- 1 x Thermocouple (for temperature measurement)
- 2 x AAA batiri
4. Ọja Awọn ẹya ara ẹrọ ati irinše
The HT118A multimeter is designed with user-friendly features and robust construction:
- Awọn iṣiro 6000 Ifihan: Pese ipinnu giga fun awọn wiwọn deede.
- RMS tootọ (TRMS): Accurately measures AC voltage and current for non-sinusoidal waveforms.
- Gbigbe Aifọwọyi: Automatically selects the correct measurement range, simplifying operation.
- Non-Olubasọrọ Voltage (NCV) Iwari: Ṣe awari AC voltage without physical contact, indicated by sound and light.
- Live Wire Function: Identifies live wires, with the screen changing to red for clear indication.
- LED Lighting Jacks: Flashing jacks guide correct probe placement for selected functions.
- Ina Filaṣi ti a dapọ: For illumination in dimly lit work areas.
- Idaduro data (HOLD): Didi kika lọwọlọwọ lori ifihan.
- Max/Min Data (MAX/MIN): Ṣe àkọsílẹ̀ iye tí ó pọ̀jù àti èyí tí ó kéré jùlọ tí a wọ̀n.
- Atọka Batiri Kekere: Àwọn ìkìlọ̀ nígbà tí a bá nílò àyípadà bátírì.
- Pipa Agbara Aifọwọyi: Ṣe itọju igbesi aye batiri nipa pipa a laifọwọyi lẹhin akoko aiṣiṣẹ.
- Àpò Ààbò Silikoni: Provides durability and protection against drops.
- Dual PTC and Dual Ceramic Fuse: Enhanced safety features for overcurrent protection.

Figure 3: Display Features (Low Battery, Bar Graph, Orange Screen)

Figure 4: Auto-Ranging Rotary Dial

Figure 5: LED Lighting Jacks for Probe Guidance
5. Eto
5.1 Fifi sori batiri
The multimeter requires 2 x AAA batteries (included). To install or replace batteries:
- Rí i dájú pé a ti pa multimeter náà, kí o sì yọ gbogbo àwọn ìtọ́wò ìdánwò kúrò.
- Wa ideri iyẹwu batiri ni ẹhin ẹyọ naa.
- Lo screwdriver lati ṣii yara batiri naa.
- Fi awọn batiri AAA mẹta sii, ki o si kiyesi polarity ti o tọ (+/-).
- Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.
5.2 Nsopọ Awọn itọsọna Igbeyewo
Always connect the black test lead to the 'COM' (common) jack. Connect the red test lead to the appropriate input jack based on the measurement function:
- VΩHz%mAµA: Fun voltage, resistance, frequency, duty cycle, capacitance, and small current measurements.
- 10A: For large current measurements (up to 10A).

Figure 6: Multimeter with Test Leads and Thermocouple
6. Awọn ilana Iṣiṣẹ
Turn the rotary dial to select the desired measurement function. The multimeter will automatically select the appropriate range (auto-ranging).
6.1 Measuring DC/AC Voltage (V)
- Turn the rotary dial to the 'V' position (DC or AC as indicated).
- So awọn okun idanwo pọ ni afiwe si Circuit tabi paati ti a n wọn.
- Ka voltage iye lori ifihan.
6.2 Measuring DC/AC Current (A)
- Turn the rotary dial to the 'mA' or '10A' position, depending on the expected current.
- For currents up to 600mA, use the 'mAµA' jack. For currents up to 10A, use the '10A' jack.
- So awọn asiwaju igbeyewo ni jara pẹlu awọn Circuit.
- Ka iye lọwọlọwọ lori ifihan naa.
6.3 Ìwọ̀n Àìdádúró (Ω)
- Turn the rotary dial to the 'Ω' position.
- Ensure the circuit is de-energized before connecting the test leads.
- So awọn itọsọna idanwo kọja paati lati wiwọn resistance rẹ.
- Ka iye resistance lori ifihan.
6.4 Igbeyewo Ilọsiwaju
- Turn the rotary dial to the 'Ω' position.
- So awọn itọsọna idanwo kọja Circuit tabi paati.
- If continuity exists (low resistance), the multimeter will emit an audible beep.
6.5 Non-olubasọrọ Voltage (NCV) erin
- Turn the rotary dial to the 'NCV Live' position.
- Hold the top of the multimeter near the conductor or outlet.
- The multimeter will beep and the NCV indicator will light up if AC voltage ti ri.

Figure 7: Continuity and NCV Detection
6.6 Wiwaya Laaye
- Turn the rotary dial to the 'NCV Live' position.
- Insert the red test lead into the live terminal of an AC outlet or touch it to a live wire.
- The screen will turn red and an alarm will sound if a live wire is detected.

Figure 8: Live Wire Detection with Red Screen Indication
6.7 Measuring Temperature (°C/°F)
- Turn the rotary dial to the '°C/°F' position.
- Connect the thermocouple to the appropriate input jacks (usually the VΩHz%mAµA and COM jacks, observing polarity).
- Fi ohun elo thermocouple naa si ori tabi nitosi ohun ti a fe won iwọn otutu re.
- Ka iwọn otutu lori ifihan.
6.8 Other Functions (FUNC, HOLD, MAX/MIN)
- Bọ́tìnì FUNK: Press to switch between different sub-functions within a single rotary dial position (e.g., AC/DC, Diode/Continuity).
- Bọtini Dimu: Tẹ lati di kika lọwọlọwọ lori ifihan naa. Tẹ lẹẹkansi lati tu silẹ.
- Bọtini Max/MIN: Press to enter MAX/MIN mode. The meter will display the maximum or minimum value recorded since entering the mode. Press again to cycle through MAX, MIN, and exit.
7. Itọju
7.1 Ninu
Pa ọran naa pẹlu ipolowoamp cloth and mild detergent. Do not use abrasives or solvents. Keep the jacks free of dust and debris.
7.2 Batiri Rirọpo
Refer to Section 5.1 for battery replacement instructions. Replace batteries when the low battery indicator appears on the display to ensure accurate readings.
7.3 Fiusi Rirọpo
The HT118A is equipped with dual ceramic fuses for protection. If the multimeter fails to measure current, the fuse may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the specifications for the correct fuse type and rating.

olusin 9: Ti abẹnu View showing Dual PTC and Dual Ceramic Fuses
8. Laasigbotitusita
- Ko si Ifihan/Agbara: Ṣayẹwo fifi sori batiri ati rii daju pe awọn batiri ko dinku. Rọpo ti o ba wulo.
- Awọn kika ti ko tọ: Ensure test leads are correctly connected to the appropriate jacks and the rotary dial is set to the correct function/range. Check for damaged test leads.
- Ko si Beep Tesiwaju: Ensure the circuit is de-energized. Check if the component has very high resistance.
- A ko ri NCV: Ensure the NCV function is selected and the meter is held close enough to the AC voltage orisun.
9. Awọn pato

Figure 10: KAIWEETS HT118A Detailed Specifications
| Ẹka | Paramita | Ibiti & Yiye |
|---|---|---|
| Gbogboogbo | Brand | KAIWEETS |
| Iru | Digital Multimeter | |
| Awoṣe | HT118A | |
| Wiwọn | DC Voltage | 600mV/6V/60V/600V/1000V, ±(0.5%+3) |
| AC Voltage | 600mV, ±(0.8%+3); 6V/60V/600V/750V, ±(0.8%+3) | |
| DC Lọwọlọwọ | 600uA/6000uA/60mA/600mA, ±(1.0%+3); 10A, ±(1.5%+3) | |
| AC Lọwọlọwọ | 600uA/6000uA/60mA/600mA, ±(1.0%+3); 10A, ±(1.5%+3) | |
| Atako | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ, ±(0.8%+5) | |
| Agbara | 10nF/100nF/1μF/10μF/100μF/1mF/10mF, ±(4.0%+3); 100mF, ±(5.0%+3) | |
| Igbohunsafẹfẹ | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz, ±(1.0%+3) | |
| Ojuse Cycle | 1%~99%, ±(1.0%+2) | |
| Iwọn otutu | -40°C~1000°C; -40°F~1832°F, ±(1.0%+3) | |
| Ti ara | Iwọn Ọja | 0.62kg |
| Package iwuwo | 0.62kg | |
| Iwọn idii (L x W x H) | 19 x 9 x 5.5cm |
10. Awọn imọran olumulo
- For quick checks of AC voltage presence, the NCV function is very convenient and safer than using test leads.
- When measuring current, always ensure the multimeter is connected in series with the load and the correct input jack (mA or 10A) is used to avoid damaging the device or blowing a fuse.
- The kickstand on the back of the multimeter allows for hands-free operation, improving safety and convenience during measurements.
- Remember to turn the multimeter OFF when not in use to conserve battery life.
11. Atilẹyin ọja ati Support