This manual provides detailed instructions for the installation, operation, and maintenance of your Anern AN-FGI-AS 3600W Solar Inverter. This pure sine wave inverter with a 120A MPPT charge controller is designed to provide reliable power for various applications, including home, RV, and off-grid solar systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Awọn ilana aabo
Ifarabalẹ:
- The starting power of inductive loads (e.g., motors, compressors) should be at least three times the rated power of the inverter. Excessive power on can damage the inverter.
- Connect the circuits correctly and install appropriate circuit breakers for each circuit to prevent damage and ensure safety.
- Always follow the correct power-on and power-off sequence to protect the inverter and connected equipment.
Awọn iṣọra Aabo Gbogbogbo:
- Rí i dájú pé a fi ẹ̀rọ inverter náà sí ibi tí afẹ́fẹ́ ti ń tàn kálẹ̀ dáadáa, kúrò lọ́dọ̀ àwọn ohun èlò tí ó lè jóná àti ọrinrin.
- Do not attempt to open or repair the inverter yourself. Refer all servicing to qualified personnel.
- Keep children and unauthorized persons away from the inverter and its connections.
- Wọ ohun elo aabo ara ẹni ti o yẹ (PPE) nigbati o ba n ṣiṣẹ pẹlu awọn eto ina.
3. Ọja Ipariview ati Awọn ẹya ara ẹrọ
The Anern AN-FGI-AS 3600W Solar Inverter is a versatile power solution with advanced features for efficient energy management.
Awọn ẹya pataki:
- Pure sine wave output for compatibility with sensitive electronics.
- Configurable igbewọle voltagibiti o wa fun awọn ohun elo ile ati awọn kọnputa ti ara ẹni nipasẹ eto LCD.
- Agbara gbigba agbara batiri ti a le ṣatunṣe da lori awọn ohun elo nipasẹ eto LCD.
- Aṣeyọri AC/Solar Charger ti a le ṣatunṣe nipasẹ eto LCD.
- Ni ibamu pẹlu mains voltage tabi monomono agbara.
- Automatic restart while AC is recovering.
- Built-in protections: Overload, Over temperature, Short circuit.
- Apẹrẹ ṣaja batiri Smart fun iṣẹ batiri iṣapeye.
- Ibẹrẹ iṣẹ tutu.
- Ṣiṣẹda batiri Lithium ti a ṣe sinu rẹ laifọwọyi.
- Ga PV igbewọle voltage ibiti (60-500VDC).
- Multiple operating modes: INVERTER MODE, PV MODE, UTILITY MODE.
- Ìmúpadàbọ̀sípò kọ́kọ́rọ́ kan sí àwọn ètò ilé-iṣẹ́.
- Intelligent Remote Monitoring capability.
- Emergency Operation support.
- Military-grade Protection Performance.
- LCD Screen Display for easy monitoring.
- Efficient Charging Output.




4. Awọn pato
| Iwa | Iye |
|---|---|
| Nọmba awoṣe | AN-FGI-AS 3600W |
| Orukọ Brand | ANERN |
| Ojade Irisi | MEJI |
| Ijade lọwọlọwọ | 18A |
| Igbohunsafẹfẹ Ijade | 50Hz |
| Iwọn | 550 * 430 * 210mm |
| Iwọn | 10kg |
| Se Smart Device | Bẹẹni |
| Ipilẹṣẹ | Orile-ede China |
| Ijẹrisi | CE, RoHS |
| Kemikali ti o ni ifiyesi giga | Ko si |

5. Eto ati fifi sori
Fífi sori ẹrọ to peye ṣe pataki fun iṣẹ ailewu ati imunadoko ti inverter oorun rẹ. Jọwọ tẹle awọn itọsọna wọnyi ni pẹkipẹki.
Awọn igbesẹ fifi sori ẹrọ:
- Iṣagbesori: Choose a suitable location for mounting the inverter. Ensure it is a well-ventilated area, protected from direct sunlight, moisture, and extreme temperatures.
- Asopọmọra:
- Connect the battery bank to the inverter's battery terminals. Ensure correct polarity (positive to positive, negative to negative).
- Connect the solar PV array to the inverter's PV input terminals. Observe correct polarity and voltage limits (60-500VDC).
- Connect the AC input (mains or generator) to the inverter's AC input terminals.
- Connect your loads (appliances) to the inverter's AC output terminals.
- Install appropriate circuit breakers for each circuit (battery, PV, AC input, AC output) as per local electrical codes.
- Agbara-Lori Ọkọọkan:
- First, turn on the battery.
- Then, start the inverter.
- Next, turn on the circuit breakers for photovoltaic (PV) input.
- Finally, turn on the circuit breakers for mains (AC input) and load (AC output).
- Power-Off Sequence (Reverse Order):
- Turn off the circuit breakers for load and mains.
- Turn off the circuit breakers for photovoltaic (PV) input.
- Pa ẹrọ oluyipada.
- Finally, turn off the battery.

6. Awọn ilana Iṣiṣẹ
Your Anern solar inverter offers flexible operation modes and settings via its LCD display.
Awọn ọna ṣiṣe:
- INVERTER MODE: The inverter converts DC power from batteries into AC power for your loads.
- PV MODE: Prioritizes solar power to supply loads and charge batteries.
- UTILITY MODE: Prioritizes grid power to supply loads and charge batteries.
Awọn Eto LCD:
The LCD display allows you to configure various parameters:
- Iṣagbewọle Voltage Ibiti: Adjust for compatibility with home appliances or personal computers.
- Ngba agbara Batiri lọwọlọwọ: Set the charging current based on your battery type and capacity.
- Ṣaja AC/Oorun pataki: Define whether AC or solar charging takes precedence.
- Factory Settings Restoration: Use the one-key restoration function to revert to default settings if needed.
Refer to the on-screen menu for detailed navigation and parameter adjustments.
7. Itọju
Itọju deede ṣe idaniloju igbesi aye gigun ati iṣẹ ti o dara julọ ti oluyipada rẹ.
- Ninu: Periodically clean the inverter's exterior with a dry, soft cloth. Ensure ventilation openings are free from dust and debris.
- Awọn isopọ: Lododun ṣayẹwo gbogbo awọn asopọ itanna fun wiwọ ati awọn ami ti ipata.
- Ayika: Rii daju pe ayika fifi sori ẹrọ wa laarin iwọn otutu pato ati awọn sakani ọriniinitutu.
- Ilera Batiri: Monitor battery health and ensure they are properly maintained according to their manufacturer's guidelines.
Warning: Disconnect all power sources (PV, AC, Battery) before performing any maintenance or cleaning.
8. Laasigbotitusita
Abala yii n pese awọn ojutu si awọn ọran ti o wọpọ ti o le ba pade. Fun awọn iṣoro ti ko ṣe akojọ si ibi, jọwọ kan si atilẹyin alabara.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Oluyipada ko titan | No battery power; incorrect wiring; faulty switch | Check battery connections and charge level; verify all wiring; ensure power switch is ON. |
| Ko si AC jade | Overload; short circuit; low battery voltage; inverter fault | Reduce load; check for short circuits; charge batteries; restart inverter. |
| PV charging not working | No sunlight; PV array disconnected; incorrect PV voltage | Check solar conditions; verify PV connections; ensure PV voltage is within range (60-500VDC). |
| Overload/Over temperature error | Too many loads; insufficient ventilation | Reduce connected loads; ensure proper airflow around the inverter. |
9. Awọn imọran olumulo
- For optimal battery life, ensure your battery charging current settings match your battery manufacturer's recommendations.
- When using inductive loads, remember the "three times rated power" rule for starting power to avoid inverter damage.
- Regularly check the LCD display for system status and any error codes to proactively address potential issues.
10. Atilẹyin ọja ati Support
The Anern AN-FGI-AS 3600W Solar Inverter is certified with CE and RoHS, ensuring compliance with European safety and environmental standards.
For technical support, warranty claims, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.