1. Ifihan ọja
This NIDEC TA225DC B34605-33 cooling fan is designed with a high-efficiency motor and optimized blade structure to provide rapid device cooling through forced air convection. It offers ample airflow, stable operation, low noise, long service life, and easy installation. This fan is widely used in various electrical equipment and industrial devices that require ventilation and heat dissipation.
Ibi to wulo: Chassis, cabinets, power supplies, industrial control equipment, home appliances, ventilation and cooling systems.

olusin 1: Iwaju view of the NIDEC TA225DC B34605-33 cooling fan.

olusin 2: Pada view of the NIDEC TA225DC B34605-33 cooling fan.
2. Imọ ni pato
DC Fan (Model: TA225DC B34605-33)
| Iwa | Iye |
|---|---|
| Brand | NIDEC |
| Nọmba awoṣe | TA225DC B34605-33 |
| Iwọn | 60 * 60 * 25mm |
| Oṣuwọn Voltage | DC 12V |
| Lọwọlọwọ | 0.58A |
| Agbara | 6.96W |
| Iyara Yiyipo | 6800 RPM |
| Fife ategun | 32 CFM |
| Ariwo | 43 dB(A) |
| Ti nso | Two Ball Bearing |
| Awọn ila | 3 ILA |
| Ọlọpọọmídíà Interface | Awọn miiran |
| Lo Fun | Ọran, Radiator |
| Ijẹrisi | CE |
| Package | Bẹẹni |
| Kemikali ti o ni ifiyesi giga | Ko si |
General DC Fan Specifications (from manual)
- Oṣuwọn Voltage: DC 12V / 24V
- Awọn ọna Voltage Range: ±10% of rated voltage
- Rotational Speed: 2000-4500 RPM
- Airflow: 30-120 CFM
- Noise: 22-45 dB(A)
- Wiring Definition: Red wire (positive), Black wire (negative), Yellow wire (tachometer), Blue wire (PWM speed control)
General AC Fan Specifications (from manual)
- Oṣuwọn Voltage: AC 110V / 220V
- Igbohunsafẹfẹ: 50/60Hz
- Iyara: 2200-2800 RPM
- Kilasi idabobo: B
- Kilasi Idaabobo: IP44
3. Itọsọna fifi sori ẹrọ
- Agbara Pa: Before installation, the device must be powered off. Operation with power on is strictly prohibited.
- Confirm Fan Direction: The airflow outlet should face outward, and the airflow inlet should face inward toward the device.
- Iṣagbesori to ni aabo: Use matching screws to secure evenly. Avoid screws that are too long, as they may damage the internal structure of the fan.
- Asopọmọra: Wiring must strictly follow the labels. Reverse connection, incorrect connection, or short circuit is strictly prohibited.
- Ṣayẹwo fifi sori lẹhin: After installation, check that the fan blades move freely and are not loose. Then, power on to test.
4. Awọn ilana fun Lilo
- Isẹ akọkọ: After powering on, the fan should start smoothly without shaking or unusual noise. This is considered normal operation.
- Iṣakoso iyara: Models with speed measurement and speed adjustment functions can connect to the corresponding interfaces for speed monitoring and automatic speed control.
- Ṣe itọju ṣiṣan afẹfẹ: Keep the fan's air inlet and outlet unobstructed and free of debris during use.
- Ayika Ṣiṣẹ: Do not operate continuously in environments exceeding the rated voltage tabi iwọn otutu.
5. Itọju ati Itọju
- Ninu igbagbogbo: Regularly turn off the power to clean the fan blades and frame dust. You can use a soft brush or an air blower for cleaning.
- Yago fun Omi: Do not rinse directly with water to prevent liquid from entering the fan.
- Pre-Use Check (After Storage): After long-term storage, check the wiring and fan blades before use, and only power on after confirming there are no issues.
- Itọju Ọjọgbọn: Non-professionals should not add lubricating oil or disassemble bearings and other components.
6. Awọn iṣọra aabo
- Maṣe lo ni damp, waterlogged, flammable, explosive, or highly corrosive environments.
- When the fan is running, do not insert fingers, tools, or other foreign objects into the fan.
- Do not disassemble, modify, or press the fan blades or internal components without authorization.
- If abnormal sounds, vibrations, stoppage, or burning smells occur during operation, immediately cut off the power and check.
- This product is not explosion-proof or waterproof; do not use it in special hazardous conditions.
7. Laasigbotitusita
| Lasan aiṣedeede | Owun to le Fa | Ojutu |
|---|---|---|
| Fan ko nyi | Poor power connection, reversed polarity, abnormal voltage | Check wiring, power supply, and voltage |
| Ariwo ti o pọju | Fan blades dirty, loose installation, blocked air duct | Clean dust, tighten installation, clear air duct |
| Iyara ti ko duro | Voltage fluctuation, abnormal speed control signal | Stabilize power supply, check speed control interface |
| Fan abe di | Foreign objects, damaged bearing | Remove foreign objects, replace fan |
8. Atilẹyin ọja & Atilẹyin
- The product is covered by a warranty service against non-human damage under normal use.
- Damage caused by unauthorized modifications, water immersion, overloading, or improper installation is not covered by the warranty.
- If a performance failure occurs within the warranty period, you can contact the dealer for replacement or repair.
9. Awọn imọran olumulo
Ko si kan pato olumulo awọn italolobo wà wa lati pese tunviews tabi Q&A akoonu.
Video 1: General demonstration of a cooling fan in operation. Note: The fan shown in the video is an AVC 8025 8cm fan, not the NIDEC TA225DC B34605-33 model.
For additional information or a detailed user manual, please refer to the official PDF document: Ilana olumulo (PDF)