1. Ifihan
Thank you for choosing the Cadet 79241 Compact Electric Wall Heater. This manual provides essential information for the safe installation, operation, and maintenance of your new heater. The Cadet 79241 is a 1000-watt, 120-volt, 8.33-amp fan-forced electric wall heater designed for efficient heating in areas up to 150 square feet, such as bathrooms and workspaces. It features a nichrome coil element and an on/off switch for manual control. This product is UL listed, ensuring it meets recognized safety standards.
2. Alaye Aabo pataki
Please read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in fire, electric shock, property damage, or personal injury.
- Aabo Itanna: Always disconnect power at the main service panel before installing, servicing, or cleaning the heater. Ensure all wiring connections are secure and comply with local electrical codes.
- Ibi: Do not install the heater directly below a wall receptacle. Maintain proper clearances from combustible materials as specified in the installation instructions.
- Isẹ: Never block the air intake or exhaust vents. Do not insert any objects into the heater openings. Do not use this heater in wet or moist locations, or near bathtubs, showers, or swimming pools.
- Abojuto: Abojuto ti o sunmọ ni pataki nigbati awọn ọmọde tabi awọn alaisan ba lo eyikeyi ohun elo imuna.
- Ilana 65 Ikilọ: Ọja yii le fi ọ han si awọn kemikali pẹlu asiwaju, eyiti o mọ si Ipinle California lati fa akàn ati awọn abawọn ibimọ tabi ipalara ibisi miiran. Fun alaye diẹ sii lọ si www.P65Warnings.ca.gov.
3. Ọja Ipariview
The Cadet 79241 is a compact, fan-forced electric wall heater designed for supplemental heating. Its robust construction and simple controls make it suitable for various residential and commercial applications.
Awọn ẹya pataki:
- 1000 Watts, 120 Volts, 8.33 Amps
- Fan-forced heating for quick warmth
- Integrated on/off switch for manual control
- Nichrome coil element for continuous heat transmission
- UL Akojọ fun ailewu
- Ideal for heating up to 150 square feet

Nọmba 1: Iwaju view of the Cadet 79241 Compact Electric Wall Heater, showing the grille and on/off switch.

Nọmba 2: View of the Cadet 79241 heater with its internal components, including the fan and heating element, exposed for installation reference.
4. fifi sori
Installation of the Cadet 79241 heater requires hard-wiring to a dedicated 120-volt circuit. It is recommended that installation be performed by a qualified electrician to ensure compliance with all local and national electrical codes.
Awọn Igbesẹ Iṣaaju Iṣaaju:
- Ge asopọ agbara: Turn off power to the circuit at the main electrical panel before beginning any installation work.
- Aṣayan Ibi: Choose a wall location that allows for proper clearances from floors, ceilings, and adjacent walls. Ensure the location is not obstructed by furniture or drapes. The heater is designed for use with a wall can, such as model RBFC (sold separately).
- Asopọmọra: Run appropriate gauge electrical wiring (rated for 120V, 8.33A, 1000W) to the installation site.
Fifi sori ẹrọ ti ngbona:
- Secure the wall can (if used) into the wall opening according to its instructions.
- Connect the heater's wiring to the building's electrical supply wires inside the junction box, following the wiring diagram provided with the heater. Ensure all connections are tight and properly insulated.
- Carefully insert the heater assembly into the wall can or wall opening, securing it with the provided screws.
- Attach the front grille to the heater assembly.

Nọmba 3: The Cadet 79241 Compact Electric Wall Heater shown installed flush on a wall, providing a visual reference for proper placement.
5. Isẹ
The Cadet 79241 Compact Electric Wall Heater is designed for straightforward operation using its integrated on/off switch.
Turning the Heater On/Off:
- To turn the heater ON, locate the switch on the front panel of the heater and toggle it to the 'ON' position. The fan will activate, and the heating element will begin to produce warm air.
- To turn the heater PAA, toggle the switch to the 'OFF' position. The fan and heating element will cease operation.
This heater provides fan-forced heat, distributing warmth quickly and efficiently throughout the designated area. It is manually controlled via the on/off switch and does not feature an integrated thermostat.
6. Itọju
Regular, simple maintenance will help ensure the longevity and efficient operation of your Cadet 79241 heater.
Ninu:
- Ge Agbara: Always turn off the heater and disconnect power at the main service panel before cleaning.
- Ode Ninu: Lo asọ, damp cloth to wipe the exterior surfaces of the heater. Do not use abrasive cleaners, solvents, or spray cleaners directly on the heater.
- Fifọ Grille: Use a vacuum cleaner with a brush attachment to gently remove dust and debris from the grille openings.
No other user-serviceable parts are inside the heater. Any internal maintenance or repair should be performed by qualified service personnel.
7. Laasigbotitusita
If your Cadet 79241 heater is not operating correctly, refer to the following troubleshooting guide:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Alagbona ko ni tan-an. | Ko si agbara si ẹrọ naa. | Check the circuit breaker at the main electrical panel. Ensure the on/off switch is in the 'ON' position. |
| Heater produces no heat, but fan runs. | Alapapo ano oro. | Disconnect power and contact a qualified electrician or service technician. |
| A ti dinku iṣẹjade ooru. | Blocked air vents or dust accumulation. | Disconnect power and clean the grille and air vents as described in the Maintenance section. Ensure no objects are blocking airflow. |
| Awọn ariwo ti ko wọpọ lakoko iṣẹ. | Loose components or fan obstruction. | Disconnect power immediately. Do not attempt to repair. Contact a qualified service technician. |
If you are unable to resolve an issue using this guide, please contact Cadet customer support or a qualified electrician.
8. Awọn pato
Detailed technical specifications for the Cadet 79241 Compact Electric Wall Heater:
- Nọmba awoṣe: 79241
- Voltage: 120 Volts
- Wattage: 1000 Wattis
- Ampigba: 8.33 Amps
- Ọna gbigbona: Fan Forced Air
- Ibora alapapo: Approximately 150 square feet
- Awọn iwọn ọja: 3.88 x 10.13 x 16.88 inches (Ijinle x Iwọn x Giga)
- Ìwọ̀n Nkan: 1 iwon
- Olupese: TV Non-Branded Items (Cadet)
- UL Akojọ: Bẹẹni
9. Atilẹyin ọja ati Support
Specific warranty information for the Cadet 79241 Compact Electric Wall Heater is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact Cadet customer support directly.
Atilẹyin Onibara:
For technical assistance, replacement parts, or further inquiries, please visit the official Cadet webojula tabi kan si wọn onibara iṣẹ Eka. Alaye olubasọrọ le ṣee rii ni igbagbogbo lori apoti ọja tabi ti olupese webojula.