Intermatic T171

Intermatic T171 SPST 24 Hour 125-Volt Time Switch User Manual

awoṣe: T171

Ọrọ Iṣaaju

This manual provides detailed instructions for the installation, operation, and maintenance of your Intermatic T171 SPST 24 Hour 125-Volt Time Switch. The T171 is designed for direct 24-hour control of electrical loads, offering reliable scheduling with up to 10 ON/OFF operations per day. It features a durable steel enclosure suitable for indoor use.

Alaye Aabo

IKILO: Risk of electric shock. This device operates on 125 Volts AC. Installation and servicing should only be performed by a qualified electrician. Always turn off power at the main circuit breaker or fuse box before installing or servicing the time switch.

Ọja Pariview

The Intermatic T171 time switch consists of a robust steel enclosure housing the mechanical timer mechanism and electrical terminals. Understanding its components is key to proper installation and operation.

Ti abẹnu view of Intermatic T171 time switch showing the yellow dial, manual lever, and wiring terminals.

Figure 1: Internal Components. This image displays the internal layout of the T171 time switch. Key components include the large yellow 24-hour dial for setting time and programs, the manual ON/OFF lever, and the clearly labeled wiring terminals for Neutral (A), Line (1), and Load (2). A caution label reminds users to turn off power before servicing and not to remove the insulator.

Ita view of Intermatic T171 time switch enclosure, a gray rectangular metal box with 'INTERMATIC' embossed.

Figure 2: External Enclosure. This image shows the robust gray steel enclosure of the Intermatic T171 time switch. The enclosure is designed for indoor wall mounting and provides protection for the internal components. The Intermatic logo is embossed on the front cover.

Eto ati fifi sori

Proper installation is critical for the safe and effective operation of your time switch. This device is designed for wall mounting.

  1. Ge asopọ agbara: Before beginning any installation, ensure the main power supply to the circuit where the time switch will be installed is turned OFF at the circuit breaker or fuse box. Verify with a voltage idanwo.
  2. Iṣagbesori: Select a suitable indoor location for wall mounting. Secure the steel enclosure firmly to a wall stud or use appropriate wall anchors. The dimensions are approximately 5.13 inches wide by 7.88 inches high by 3.44 inches deep.
  3. Asopọmọra: Refer to the wiring diagram inside the enclosure (see Figure 1). Connect the electrical wires to the clearly labeled terminals:
    • Neutral (A): Connect the neutral wire from your power supply.
    • Line (1): Connect the hot (live) wire from your 125 VAC power supply.
    • Load (2): Connect the wire leading to the device or circuit you wish to control.

    Pataki: This switch is designed for copper conductors. Do not connect aluminum wires directly to the switch terminals. If aluminum wiring is present, use approved copper-to-aluminum connectors.

  4. Insulator: Ensure the protective insulator over the wiring terminals is properly in place after wiring. Do not remove this insulator permanently.
  5. Ìpadé Àpótí: Close and secure the front cover of the enclosure.
  6. Imupadabọ agbara: Mu pada agbara ni akọkọ Circuit fifọ.

Awọn ilana Iṣiṣẹ

The T171 time switch allows for precise scheduling of electrical loads.

  1. Eto Akoko lọwọlọwọ:

    Rotate the large yellow 24-hour dial clockwise until the current time aligns with the "TIME SET" arrow located at the top of the dial. The dial is marked with AM/PM indicators.

  2. Setting ON/OFF Operations:

    The dial has small segments around its perimeter. To set an ON time, push an "ON" tripper (usually green or silver) into the desired time slot on the dial. To set an OFF time, push an "OFF" tripper (usually red or black) into the desired time slot. The T171 supports 1 to 10 ON/OFF operations per day. The minimum ON or OFF time is 1 hour.

    Akiyesi: Trippers are typically supplied with the unit. Additional trippers may be purchased separately if needed for more operations.

  3. Yiyọ afọwọṣe:

    A manual lever is provided on the mechanism (see Figure 1). This lever allows you to temporarily override the programmed schedule. Move the lever to the "ON" or "OFF" position as desired. The timer will resume its programmed schedule at the next scheduled ON or OFF event.

  4. Skip-A-Day Feature:

    The T171 is a "24 Hour with Skip A Day" type timer. This feature allows you to prevent the timer from operating on specific days of the week. Consult the detailed instructions provided with your specific unit for setting the skip-a-day pins or segments, if applicable. This typically involves setting small pins on the outer edge of the dial corresponding to days you wish to skip.

Itoju

The Intermatic T171 time switch is designed for long-term, reliable operation with minimal maintenance.

Laasigbotitusita

If your Intermatic T171 time switch is not functioning as expected, consider the following common issues:

IsoroOwun to le FaOjutu
Aago ko ṣiṣẹ.No power to the unit; incorrect wiring; tripped circuit breaker.Check power supply at the breaker. Verify wiring connections (ensure power is off before inspecting).
Ẹrù kò tan/pa ní àkókò tí a ṣètò.Trippers incorrectly set; manual override engaged; incorrect current time setting.Ensure trippers are firmly in place at desired times. Check manual lever position. Verify current time is accurately set on the dial.
Timer runs but load doesn't respond.Load device malfunction; loose load wiring.Test the load device independently. Check load wiring connection at the timer (power off).
Timer makes unusual noises.Ti abẹnu darí oro.Discontinue use and contact a qualified electrician or Intermatic support.

If these steps do not resolve the issue, contact a qualified electrician or Intermatic customer support for further assistance.

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Nọmba awoṣeT171
Voltage125 VAC
Yipada IruSPST (Ọpá Kanṣoṣo, Jíjá Ẹyọ Kan)
O pọju Fifuye Lọwọlọwọ40 Amps per pole
Operations per Day1 to 10 ON/OFF operations
Minimum ON/OFF Time1 Wakati
Ohun elo apadeIrin
Apade IruType 1 Indoor Enclosure
Awọn iwọn Ọja (H x W x D)7.88" x 5.13" x 3.44"
Iwọn Nkan2.7 iwon
Awọn iwe-ẹriUL (Canada and US), CSA (Canada and US)

Alaye atilẹyin ọja

The Intermatic T171 time switch comes with a manufacturer's warranty. For specific details regarding the warranty period, coverage, and terms and conditions, please refer to the warranty description provided by Intermatic Incorporated, typically included with the product packaging or available on the official Intermatic webojula. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

Atilẹyin

For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Intermatic customer support. You can typically find contact information, including phone numbers and website details, on the product packaging or on the official Intermatic webAaye (www.intermatic.com).

When contacting support, please have your product model number (T171) and purchase information readily available.

Awọn iwe aṣẹ ti o jọmọ - T171

Ṣaajuview Intermatic GMXFM1 Electronic Time Switch Instruction Manual
Instruction manual for the Intermatic GMXFM1 electronic time switch, covering safety precautions, symbols, initial setup, programming, time settings, daylight saving adjustments, operating modes, and warranty information.
Ṣaajuview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Comprehensive details on Intermatic T170, T1400, and T1800 Series 24-Hour Electromechanical Time Switches, covering features, specifications, ratings, model variations, and wiring diagrams for commercial, industrial, and residential applications.
Ṣaajuview Intermatic ET1100 Series Electronic Time Switches: Features, Specifications, and Models
Detailed information on the Intermatic ET1100 Series 24-Hour Electronic Time Switches, including features, technical specifications, contact ratings, enclosure options, and model variations for accurate load control.
Ṣaajuview Intermatic All-Plastic Rainproof Time Switch Enclosure Installation Instructions
Detailed installation guide for the Intermatic all-plastic rainproof time switch enclosure, covering case mounting, conduit connections, and grounding requirements according to the National Electric Code.
Ṣaajuview Intermatic ET100 Series Electronic 24 Hour Time Switch Owner/Installer Manual
Comprehensive owner and installer instructions for the Intermatic ET100 Series electronic 24-hour time switches, including models ET102C, ET102CM, ET104C, and ET104CM. Covers installation, programming, troubleshooting, and warranty information.
Ṣaajuview Intermatic GM40AVE Series Electronic Commercial Time Switch Installation and Operation Manual
Comprehensive installation, operation, and troubleshooting guide for the Intermatic GM40AVE Series General Purpose Electronic Commercial Time Switches. Includes electrical ratings, wiring diagrams, application details, and warranty information. Source URL: http://waterheatertimer.org/Intermatic-timers-and-manuals.html#GM40AVE