Savio WMS3600

Ìwé Ìtọ́ni fún Pọ́ọ̀pù Omi Onímọ̀-Omi Savio WMS3600

Model: WMS3600 | Brand: Savio

1. Ifihan

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Savio WMS3600 Water Master Solids Submersible Pump. Please read these instructions thoroughly before use to ensure proper function and longevity of the product.

Savio WMS3600 Water Master Solids Submersible Pump

Image 1.1: Savio WMS3600 Water Master Solids Submersible Pump. This image displays the main unit of the submersible pump, highlighting its compact, black, cylindrical design with an integrated handle and a side outlet.

2. Alaye Aabo

Always observe the following safety precautions to reduce the risk of injury, electric shock, or product damage:

3. Awọn ẹya Ọja

The Savio WMS3600 pump incorporates several design elements for reliable performance:

Savio WMS3600 Pump Features

Image 3.1: Key features of the Savio WMS3600 pump. This image highlights the non-corrosive housing and the 1.25-inch output, along with text descriptions for solids handling, thermal overload protection, and factory testing.

4. Eto ati fifi sori

Follow these steps for proper installation of your submersible pump:

  1. Ṣii silẹ: Carefully remove the pump from its packaging. Inspect for any visible damage.
  2. Ibi: Position the pump on a stable, level surface within the pond or water feature. Ensure it is fully submerged and not resting directly on the bottom sediment. Using a pump stand or elevated platform is recommended to prevent clogging from debris.
  3. Asopọ okun: Connect appropriate hosing to the pump's outlet. The pump features a 1-1/2" outlet (with elbow). Secure the hose with a clamp lati dena jijo.
  4. Asopọmọra itanna: Route the power cord safely to a GFCI-protected electrical outlet. Ensure the cord is not pinched or damaged. Do not use extension cords unless specifically rated for outdoor, wet conditions and properly grounded.
  5. Ṣayẹwo akọkọ: Before powering on, ensure all connections are secure and the pump is fully submerged in water.

5. Isẹ

Operating your Savio WMS3600 pump is straightforward:

  1. Agbara Tan: Plug the pump into the GFCI-protected outlet. The pump should start immediately, circulating water.
  2. Bojuto Sisan: Observe the water flow to ensure it is consistent and free of obstructions.
  3. Ise Tesiwaju: This pump is designed for continuous operation. However, regular checks for debris accumulation are recommended.
  4. Paade: Láti pa pọ́ọ̀pù náà, yọ ọ́ kúrò nínú ihò iná mànàmáná náà.

6. Itọju

Regular maintenance ensures optimal performance and extends the life of your pump:

7. Laasigbotitusita

Tọkasi apakan yii fun awọn ọran ti o wọpọ ati awọn ojutu wọn:

IsoroOwun to le FaOjutu
Pump does not start or operate.No power; GFCI tripped; clogged impeller; motor overload.Check power connection and GFCI. Disconnect power, clear impeller, allow motor to cool if overloaded.
Dinku sisan omi.Clogged intake or impeller; kinked or obstructed hose; low water level.Disconnect power, clean intake and impeller. Check hose for obstructions. Ensure pump is fully submerged.
Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n omi kò sí.Air lock; completely blocked intake/impeller.Disconnect power, remove pump, shake gently to release air, re-submerge. Clear any severe blockages.
Pump trips GFCI repeatedly.Electrical fault; damaged cord; water in motor housing.Inspect cord for damage. If problem persists, discontinue use and contact qualified service personnel.

8. Awọn pato

Detailed technical specifications for the Savio WMS3600 Water Master Solids Submersible Pump:

IwaIye
AwoṣeWMS3600
BrandOlugbala
Oṣuwọn Sisan ti o pọju3,600 GPH (60 Glọ́ọ̀nù fún ìṣẹ́jú kan)
Ti aipe Awọn ọna Ibiti1440 gph - 2880 gph
O pọju Ori25 Ẹsẹ
Voltage115 Volts
Wattage650 Wattis
Ampigba6 Amps
Hertz60 Hz
Iwon iṣan1-1/2" (with elbow)
Imudani ri toUp to 1 inch
Awọn iwọn (L x W x H)10 x 8 x 14 inches (isunmọ)
Iwọn Nkan8 iwon
Okun Gigun16 Ẹsẹ
Ohun eloṢiṣu
Orisun agbaraAC
Àwọ̀Dudu
Savio WMS3600 Pump Dimensions

Image 8.1: Savio WMS3600 pump with approximate dimensions. The image shows the pump with labels indicating a height of 13"-14" and a width of 6".

Awọn shatti iṣẹ

Savio Water Master Solids Specifications Chart

Image 8.2: Savio Water Master Solids Specifications Chart. This chart provides detailed specifications for various WMS models, including dimensions, amps, watts, volts, outlet size, hertz, max flow, optimal operating range, max head, and average monthly operating cost.

Water Master Solids Flow Rates Chart

Image 8.3: Water Master Solids Flow Rates (gallons per hour) versus Max Head Pressure (in feet) chart. This graph illustrates the performance curves for different Savio WMS pump models (WMS1450, WMS2050, WMS3600, WMS5000, WMS6500).

Savio Water Master Solids Pumps Comparative Specifications

Image 8.4: Comparative specifications table for Savio Water Master Solids Pumps. This table lists pump model, dimensions, max flow, cord length, watts, volts, amps, and max head for various models.

9. Atilẹyin ọja ati Support

The Savio WMS3600 Water Master Solids Submersible Pump comes with a 2-Odun olupese atilẹyin ọja. For warranty claims or technical support, please contact Savio customer service directly. Retain your proof of purchase for warranty validation.

For additional information or to locate authorized service centers, please visit the official Savio webaaye tabi tọka si alaye olubasọrọ ti a pese pẹlu apoti ọja rẹ.

Awọn iwe aṣẹ ti o jọmọ - WMS3600

Ṣaajuview Ajọ Savio Livingponds F100 & F200: Ilana Ṣiṣẹ & Itọsọna fifi sori ẹrọ
Itọsọna okeerẹ fun fifi sori ẹrọ ati sisẹ Savio Livingponds Waterfall Filter (F100) ati Filter Wapọ (F200). Ni wiwa awọn paati, gbigbe, apejọ, fifi ọpa, itọju, ati laasigbotitusita fun awọn ọgba omi.
Ṣaajuview Atunto HARD Procedura dla urządzeń TVBOX SAVIO: Awoṣe 02, B01, P01, G01
Szczegółowa instrukcja wykonania twardego resetu (atunto ile-iṣẹ) dla urządzeń TVBOX marki SAVIO, obejmująca modele 02, B01, P01, G01. Przywróć ustawienia fabryczne ati rozwiąż problemy z urządzeniem.
Ṣaajuview SAVIO AP-05 Travel Adapter User Manual
User manual for the SAVIO AP-05 Travel Adapter, featuring global socket compatibility and a UK plug. Includes technical specifications, instructions for use, and safety conditions.
Ṣaajuview SAVIO TWS-06 Afọwọkọ olumulo Awọn Earphones Bluetooth Alailowaya
Iwe afọwọkọ olumulo pipe fun SAVIO TWS-06 awọn agbekọri alailowaya Bluetooth, iṣeto ibora, gbigba agbara, sisopọ, iṣẹ ṣiṣe, awọn pato, ati alaye pataki. Pẹlu awọn aworan atọka ọja ati awọn alaye imọ-ẹrọ.
Ṣaajuview Savio TWS-03 Afọwọkọ Olumulo Awọn Earphones Bluetooth Alailowaya
Itọsọna olumulo fun Savio TWS-03 awọn agbekọri alailowaya Bluetooth, ti o bo apejuwe ọja, gbigba agbara, sisopọ, awọn iṣẹ bọtini, awọn akoonu package, ati awọn alaye imọ-ẹrọ.
Ṣaajuview GREENOVA R290: Note Tecniche per l'Installazione di Pompe di Calore Aria-Acqua Savio
Guida tecnica e note d'impiego per l'installazione della pompa di calore aria-acqua Savio GREENOVA R290. Informazioni essenziali per un'installazione sicura ed efficiente.