Thank you for choosing the Friedrich 11600 Btu Portable Air Conditioner. This manual provides important information for the proper installation, operation, and maintenance of your new air conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference.
Alaye Aabo pataki
Lati dinku eewu ina, mọnamọna, tabi ipalara nigba lilo afẹfẹ afẹfẹ rẹ, tẹle awọn iṣọra ipilẹ wọnyi:
- Ka gbogbo awọn ilana ṣaaju lilo ohun elo naa.
- Rii daju pe ipese agbara ibaamu voltage pato lori awọn Rating aami.
- Ma ṣe ṣisẹ afẹfẹ afẹfẹ pẹlu okun tabi plug ti o bajẹ.
- Ma ṣe dina awọn ọna afẹfẹ tabi awọn inlets.
- Yọọ kuro nigbagbogbo ṣaaju ṣiṣe mimọ tabi ṣiṣe.
- Keep the unit on a flat, stable surface to prevent water leakage.
- Ohun elo yii kii ṣe ipinnu fun lilo nipasẹ awọn eniyan (pẹlu awọn ọmọde) pẹlu idinku ti ara, imọlara tabi awọn agbara ọpọlọ, tabi aini iriri ati imọ, ayafi ti wọn ba ti fun wọn ni abojuto tabi itọnisọna nipa lilo ohun elo nipasẹ eniyan ti o ni iduro fun aabo wọn.
Package Awọn akoonu
Jẹrisi pe gbogbo awọn paati wa ati ni ipo to dara:
- Friedrich 11600 Btu Portable Air Conditioner Unit
- Isakoṣo latọna jijin
- (2) Exhaust Hoses
- Sliding Window Curtain for Each Side of the Hose to Seal Window Opening
- Afowoyi Olumulo (iwe-ipamọ yii)

An image showing the Friedrich 11600 Btu Portable Air Conditioner unit, which is white and rectangular, along with its accompanying remote control. The unit features a front grille and control panel, while the remote control has a small display and various buttons.
Ṣeto
1. Unpacking
Fi ìṣọ́ra yọ afẹ́fẹ́ àti gbogbo àwọn ohun èlò míì tó wà nínú àpótí náà. Pa àpótí àtilẹ̀wá mọ́ fún ìtọ́jú tàbí gbígbé lọ síbi tí ó yẹ lọ́jọ́ iwájú.
2. Ifiweranṣẹ
- Place the unit on a firm, level surface in a location that is not exposed to direct sunlight or heat sources.
- Rii daju pe o kere ju 20 inches (50 cm) ti aaye ni ayika ẹyọ naa fun gbigbe afẹfẹ to dara.
- The unit must be placed near a window or opening to allow for exhaust hose installation.
3. Window Apo fifi sori
The unit comes with two exhaust hoses and a sliding window curtain system for sealing the window opening.
- Attach one end of each exhaust hose to the designated exhaust ports on the back of the air conditioner.
- Extend the sliding window curtain to fit your window opening.
- Insert the other ends of the exhaust hoses into the openings in the window curtain.
- Secure the window curtain in the window frame, ensuring a tight seal to prevent outside air from entering.
- Ensure the exhaust hoses are not kinked or bent sharply, as this can restrict airflow and reduce efficiency. The maximum exhaust hose length is 5 ft.
4. Asopọ agbara
Plug the power cord into a grounded 120V, 60Hz electrical outlet. The power cord length is 6 ft. Do not use extension cords or adapter plugs.
Awọn ilana Iṣiṣẹ
Ibi iwaju alabujutoview
The control panel on the unit features buttons for Power, Mode, Fan Speed, Temperature Up/Down, and Timer. A digital display shows the current temperature or timer settings.
Awọn iṣẹ iṣakoso latọna jijin
The remote control provides full functionality from a distance. Ensure batteries are correctly installed.
- Bọtini agbara: Ó ń tan tàbí pa ẹ̀rọ náà.
- Bọtini Ipo: Cycles through cooling, fan-only, and dry (dehumidify) modes.
- Bọtini Iyara Fan: Adjusts fan speed (Low, Medium, High). There are 3 cooling speeds and 3 fan-only speeds.
- Temperature Buttons (Up/Down): Adjusts the desired temperature in cooling mode.
- Bọtini Aago: Ó ń ṣètò aago tí a fi ń tan ara ẹni tàbí tí a fi ń pa ara ẹni.
Awọn ọna ṣiṣe
- Ipo Itura: Provides cooling. Set your desired temperature using the Up/Down buttons. The unit will cycle on and off to maintain the set temperature.
- Ipo Ipele: Circulates air without cooling. Use this mode for ventilation.
- Ipo gbigbẹ (Dehumidify): Din ọriniinitutu ninu yara. Iyara àìpẹ jẹ deede ti o wa titi ni ipo yii.
Itoju
Regular maintenance ensures optimal performance and extends the life of your air conditioner.
1. Air Filter Cleaning
Ajọ afẹfẹ yẹ ki o di mimọ ni gbogbo ọsẹ meji tabi diẹ sii nigbagbogbo da lori lilo ati didara afẹfẹ.
- Paa ati yọọ kuro.
- Locate and remove the air filter (usually behind a grille).
- Wẹ àlẹmọ pẹlu gbona, omi ọṣẹ. Fi omi ṣan daradara.
- Gba àlẹmọ laaye lati gbẹ patapata ṣaaju fifi sori ẹrọ.
2. Omi Imugbẹ
The unit collects condensation during operation. Depending on humidity levels, you may need to drain the water periodically.
- Imudanu Tesiwaju: For continuous operation in high humidity, connect a drain hose (not included) to the continuous drain port and route it to a floor drain or bucket.
- Afọ omi Afowoyi: When the internal water tank is full, the unit may stop operating and display an indicator. Turn off and unplug the unit, place a shallow pan under the drain port, and remove the drain plug to empty the water.
3. Ita Cleaning
Mu ese ita kuro pẹlu asọ, damp asọ. Maṣe lo awọn kẹmika ti o lewu tabi awọn afọmọ abrasive.
4. Ibi ipamọ
Ti o ba tọju ẹyọ naa fun igba pipẹ:
- Sisan gbogbo awọn akojo omi.
- Mọ àlẹmọ afẹfẹ.
- Yọọ okun agbara naa ki o si ṣa o daradara.
- Tọju ẹyọ naa ni itura, aye gbigbẹ, ni pataki ninu apoti atilẹba rẹ.
Laasigbotitusita
Ṣaaju ki o to kan si atilẹyin alabara, gbiyanju awọn igbesẹ laasigbotitusita wọpọ wọnyi:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ni tan-an. | Kò sí agbára; okùn agbára náà ti yọ; ẹ̀rọ ìfọ́mọ́ra náà ti bàjẹ́. | Ensure unit is plugged in; check circuit breaker; try a different outlet. |
| Unit ko ni itutu ni imunadoko. | Air filter dirty; exhaust hose blocked/kinked; room too large; windows/doors open. | Clean air filter; check exhaust hose for obstructions; ensure room is sealed; verify unit BTU matches room size. |
| Omi jijo. | Unit not level; drain plug loose; internal water tank full. | Place unit on a level surface; ensure drain plug is secure; drain water from the unit. |
| Ẹka jẹ alariwo. | Ẹ̀rọ náà kò sí ní ojú ilẹ̀ tí ó tẹ́jú; ìdènà afẹ́fẹ́. | Ensure unit is on a level surface; check for foreign objects near fan. |
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | P12B |
| Agbara Itutu | 11,600 BtuH |
| Voltage | 120 Volts |
| Igbohunsafẹfẹ | 60 Hz |
| Ampigba | 11.5 Amps |
| Agbara agbara | 1351 Wattis |
| Ariwo Ipele | 48 dB |
| Iwọn (D x W x H) | 15.5"D x 19.25"W x 33.63"H |
| Firiji | R 410A |
| Max. Exhaust Hose Length | 5 ft. |
| Agbara Okun Ipari | 6 ft. |
| Iṣakoso Iru | Itanna pẹlu isakoṣo latọna jijin |
| Awọn iyara itutu | 3 |
| Fan-Only Speeds | 3 |
| Ibiti Oṣiṣẹ Ibaramu | Awọn iwọn 63 si 95 F |
| Supply CFM | 255 |
| Awọn ajohunše | UL/Cul |
Atilẹyin ọja ati Support
For warranty information and customer support, please refer to the warranty card included with your product or visit the official Friedrich webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.