Watts 007 QT

Watts 007 QT 1/2-inch Double Check Valve Assembly Instruction Manual

1. Ọja Ipariview

The Watts 007 QT 1/2-inch Double Check Valve Assembly is engineered to prevent the backflow of contaminated water into a potable water supply system. This device is suitable for non-health hazard, continuous pressure applications. Its robust bronze body construction ensures durability and ease of maintenance. The assembly provides protection against both backsiphonage and backpressure backflow, safeguarding water quality.

Awọn ẹya pataki pẹlu:

Watts 007 QT 1/2-inch Double Check Valve Assembly

Image 1.1: Watts 007 QT 1/2-inch Double Check Valve Assembly. This image displays the bronze body construction and overall compact design of the valve assembly.

2. Alaye Aabo

IKILO: Improper installation or maintenance of this device can lead to serious injury or property damage. Always adhere to local plumbing codes and regulations.

3. Eto ati fifi sori

The Watts 007 QT Double Check Valve Assembly is designed for horizontal or vertical installation, depending on local codes and specific model requirements. Ensure proper orientation for optimal performance.

3.1 Pre-Fifi sọwedowo

3.2 fifi sori Igbesẹ

  1. Pa Ipese Omi Pa: Locate the main water shut-off valve and turn off the water supply to the area where the backflow preventer will be installed. Drain the system to relieve pressure.
  2. Yan Ibi: Choose an accessible location for installation that allows for future maintenance and testing. The device should be installed downstream of the main water meter and upstream of any connections that could introduce contaminants.
  3. Mura Pipa: Cut and prepare the existing piping to accommodate the 1/2-inch inlet and outlet connections of the valve assembly. Ensure pipe ends are clean and free of burrs.
  4. Fi àtọwọdá sori ẹrọ: Install the Watts 007 QT assembly into the pipeline, ensuring the flow arrow on the valve body points in the direction of water flow. Use appropriate thread sealant on all connections.
  5. Mu awọn isopọ pọ: Securely tighten all connections to prevent leaks, but do not overtighten, which could damage the bronze body or fittings.
  6. Ipese Omi Ṣiṣi: Slowly open the main water shut-off valve to gradually repressurize the system. Check all connections for leaks.
  7. Idanwo akọkọ: After installation, the device should be tested by a certified backflow prevention device tester to ensure proper operation and compliance with local regulations.

4. Isẹ

The Watts 007 QT Double Check Valve Assembly operates automatically to prevent backflow. It contains two independently operating check valves that close to prevent reverse flow when a backflow condition occurs.

5. Itọju

Regular maintenance and testing are crucial to ensure the continued proper function of your Watts 007 QT Double Check Valve Assembly. This device is designed for ease of service.

5.1 Annual Testing

Local regulations typically require annual testing of backflow prevention devices by a certified tester. This ensures the device is operating correctly and providing the required level of protection.

5.2 Iṣẹ ati Titunṣe

The modular construction and top-entry design facilitate easy servicing. If testing indicates a malfunction, the internal components can be accessed and replaced without removing the entire assembly from the pipeline.

6. Laasigbotitusita

This section provides guidance for common issues. For complex problems or issues related to backflow prevention, always consult a certified professional.

6.1 Wọpọ Oran ati Solusan

If you encounter issues not listed here or are unsure about a repair, contact Watts customer support or a qualified plumbing professional.

7. Awọn pato

Nọmba awoṣe007 QT (Part # 0062131)
Iwọn1/2 inch
Ohun eloBronze, Silicone
Ipari odeIdẹ
Iwon Asopọ Inleti0.5 inches
Asopọmọra IruDouble Ṣayẹwo àtọwọdá Apejọ
Iwon Asopọ iṣan0.5 inches
Opopona Asopọmọra IruFNPT
Iwọn Iṣiṣẹ ti o pọju175 psi (igi 12.06)
Nọmba ti Ports2
Iwọn Nkan3.45 iwon
Awọn iwọn Ọja (L x W x H)1 x 0.39 x 0.39 inches
Pato sipesifikesonuASSE 1015, AWWA C510, CSA B64.5, IAPMO PS31

8. Atilẹyin ọja ati Support

For specific warranty information regarding your Watts 007 QT Double Check Valve Assembly, please refer to the documentation included with your purchase or visit the official Watts website. Warranty terms typically cover manufacturing defects under normal use and service.

8.1 Onibara Support

If you require technical assistance, have questions about installation, operation, or maintenance, or need to inquire about replacement parts, please contact Watts customer support:

When contacting support, please have your product model number (007 QT) and any relevant purchase information readily available.

Awọn iwe aṣẹ ti o jọmọ - 007 QT

Ṣaajuview Watts Irin Alagbara Double Check Valve GBS Kit (007-SS-GBS) - Ìwádìí Ìmọ̀-ẹ̀rọ
Technical specifications, product codes, dimensions, and features for the Watts 007-SS-GBS Stainless Steel Double Check Valve with Geared Butterfly Valve and Strainer. Designed for backflow prevention in medium and low hazard installations.
Ṣaajuview Watts Series 709, LF709, 709DCDA Double Check Valve Assemblies: Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 709, LF709, and 709DCDA Double Check Valve Assemblies and Double Check Detector Assemblies, covering sizes 2½" to 10". Includes installation guidelines, servicing procedures, troubleshooting, and information on add-on monitoring kits.
Ṣaajuview Watts 007-SS-LBS Irin Alagbara Irin Double Ṣayẹwo Fáìlì Ìmọ̀-ẹ̀rọ Dáta
Ìwé ìwádìí ìmọ̀-ẹ̀rọ fún Watts 007-SS-LBS Silver Stallion Stallion Stallion Stallion, tí ó ní àwọn ìwọ̀n, àwọn kódì ọjà, àwọn ìlànà ìmọ̀-ẹ̀rọ, àti àwọn ìlà ànímọ́ fún ààbò ìpèsè omi.
Ṣaajuview Watts Series 800M4, LF800M4 Pressure Vacuum Breaker Assemblies: Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing Watts Series 800M4 and LF800M4 Pressure Vacuum Breaker Assemblies. Covers safety, installation procedures, servicing, freeze protection, and warranty.
Ṣaajuview Ibudo Idaabobo Flow Watts Series PVS-7000 pẹlu Imọ-ẹrọ Alert SentryPlus
Imọ-ẹrọ ti pariview of the Watts Series PVS-7000 Flood Protection Valve Station, featuring SentryPlus Alert technology for automatic flood detection and shutdown. Includes specifications, installation guidance, and features for preventing property damage.
Ṣaajuview Watts LFF113FP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology
Detailed information on the Watts LFF113FP Wireless Smart Flood Protection Shut Down Valve, including its features, materials, operation, specifications, and flow data. This valve is designed to automatically shut off water flow in case of continuous discharge from an RPZ Backflow Preventer.