1. Ifihan
Welcome to the Fantech FG6 Inline Exhaust Fan user manual. This document provides essential information for the safe and efficient installation, operation, and maintenance of your Fantech FG6 inline centrifugal fan. Please read this manual thoroughly before installation and use, and retain it for future reference.
The Fantech FG6 is a high-performance inline centrifugal fan designed for various residential and commercial ventilation applications, including kitchen range hoods, bathroom exhaust, duct air boosting, and commercial dryer or steam exhaust systems. It features a robust galvanized steel construction and is engineered for efficient air movement.
2. Alaye Aabo
To ensure safe operation and prevent damage to the unit or injury to personnel, observe the following safety precautions:
- Ge Agbara: Always disconnect power to the fan at the circuit breaker before performing any installation, maintenance, or cleaning.
- Oṣiṣẹ ti o peye: Installation and electrical wiring must be performed by qualified and licensed personnel in accordance with all applicable local and national codes.
- Ilẹ-ilẹ ti o tọ: Rí i dájú pé afẹ́fẹ́ náà ti lẹ̀ dáadáa láti dènà ìkọlù iná mànàmáná.
- Yago fun Awọn ohun elo ina: Do not install or operate the fan near flammable or explosive materials, gases, or vapors.
- Iṣagbesori to ni aabo: The fan must be securely mounted to a stable structure to prevent vibration and potential dislodgement.
- Ductwork Integrity: Ensure all duct connections are sealed to prevent air leakage and maintain system efficiency.
- Awọn idiwọn iwọn otutu: Do not expose the fan to airstream temperatures exceeding 140°F (60°C).
- Lilo ti a pinnu: Use this fan only for its intended purpose as described in this manual.
The Fantech FG6 fan is tested and approved by UL and CSA, ensuring compliance with recognized safety standards.
3. Package Awọn akoonu
Daju pe gbogbo awọn nkan wa ati pe ko bajẹ lori ṣiṣi silẹ:
- Fantech FG6 Inline Exhaust Fan
- Okun agbara
- Afowoyi Olumulo (iwe-ipamọ yii)
If any components are missing or damaged, contact your supplier immediately.
4. Eto ati fifi sori
4.1 Akojọ aṣyn fifi sori ẹrọ tẹlẹ
- Ensure the fan is undamaged.
- Confirm you have the necessary tools and mounting hardware (not included).
- Verify that the ductwork is 6 inches in diameter.
- Ensure the installation location provides adequate space for the fan and future maintenance access.
4.2 Iṣagbesori Fan
The Fantech FG6 fan is designed for inline installation within a 6-inch duct system. It can be mounted in any orientation.
- Yan Ibi: Choose a location that allows for secure mounting and easy access for maintenance. Consider minimizing vibration and noise transmission by selecting a sturdy mounting surface.
- Iṣagbesori to ni aabo: Use appropriate mounting hardware (e.g., straps, brackets, screws – not included) to securely fasten the fan to a stable structure.
- Isopọ ọna opopona: Connect standard 6-inch spiral flexible ducts or rigid duct systems to both the inlet and outlet of the fan. Ensure all connections are sealed using duct tape or clamps to prevent air leakage and optimize performance.
4.3 Itanna Asopọ
WARNING: All electrical work must be performed by a qualified electrician and comply with all local and national electrical codes. Disconnect power at the circuit breaker before wiring.
- Connect the fan's power cord to a suitable electrical supply.
- Ensure proper grounding of the fan to prevent electrical hazards.
- Refer to the wiring diagram provided on the fan's label or in this manual for specific connections.

Image: Fantech FG6 Inline Exhaust Fan. This image displays the galvanized steel construction of the fan, highlighting its 6-inch duct connections and the integrated electrical box. An AMCA Certified Ratings label is visible on the fan housing, indicating its air performance certification.
5. Awọn ilana Iṣiṣẹ
The Fantech FG6 fan operates by drawing air through its inlet and expelling it through its outlet, creating airflow within your duct system.
5.1 Titan / Pa a
Once installed and wired correctly, the fan can be controlled via an external switch (not included) connected to its power supply.
- To turn on the fan, activate the connected switch.
- To turn off the fan, deactivate the switch.
5.2 Airflow Itọsọna
The fan is designed to move air in a specific direction. An arrow indicating the intended airflow direction is typically located on the fan housing. Ensure the fan is installed to move air in the desired direction for your ventilation system.
6. Itọju
Itọju deede ṣe idaniloju iṣẹ ṣiṣe ti o dara julọ ati igbesi aye gigun ti olufẹ Fantech FG6 rẹ.
6.1 Ninu
WARNING: Always disconnect power to the fan at the circuit breaker before performing any maintenance or cleaning.
- Igbohunsafẹfẹ: Inspect the fan and impeller blades every 3-6 months, or more frequently in dusty or greasy environments.
- Ilana:
- Disconnect power to the fan at the circuit breaker.
- Remove any access panels or disconnect ductwork as needed to access the impeller.
- Carefully clean the impeller blades and fan housing using a soft brush or cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the fan's finish or components.
- Ensure no debris, dust, or grease obstructs the fan's operation.
- Reassemble any removed parts and reconnect ductwork.
- Mu agbara pada si afẹfẹ.
The Fantech FG6 fan features permanently lubricated sealed ball bearings, requiring no additional lubrication throughout its lifespan.
7. Laasigbotitusita
Tọkasi tabili ni isalẹ fun awọn ọran ti o wọpọ ati awọn solusan agbara wọn:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Fan ko bẹrẹ | Ko si ipese agbara Aṣiṣe onirin Gbona apọju tripped | Ṣayẹwo Circuit fifọ ati agbara yipada Verify electrical connections (consult electrician) Allow fan to cool; check for obstructions |
| Afẹfẹ ti o dinku | Iṣẹ ọna ti dina Dirty impeller blades Air leaks in duct system | Inspect and clear ducts Clean impeller blades (see Maintenance) Seal all duct connections |
| Ariwo ti o pọju | Iṣagbesori alaimuṣinṣin Idoti ni àìpẹ Duct vibration Motor oro | Mu ohun elo iṣagbesori pọ Clean fan (see Maintenance) Insulate ducts or use flexible connectors Contact Fantech support |
| Gbigbọn | Unbalanced impeller Iṣagbesori alaimuṣinṣin Aibojumu fifi sori | Clean impeller for debris Ensure secure mounting Re-check installation steps |
If issues persist after troubleshooting, contact Fantech customer support or a qualified technician for assistance.
8. Awọn pato
| Awoṣe | FG6 |
| Brand | Fantech |
| Air Sisan Agbara | Ẹsẹ onigun 257 fun Iṣẹju kan (CFM) |
| Iwon iho | 6 inches (Round) |
| Ohun elo | Irin Galvanized |
| Awọn iwọn Ọja (L x W x H) | 16.5 x 16.2 x 11.8 inches |
| Iwọn Nkan | 9.21 iwon |
| Orisun agbara | Okun Itanna |
| Ijẹrisi | UL, CSA |
| Awọn iwọn otutu ti nṣiṣẹ | Titi di 140°F (60°C) |
| Motor Iru | External rotor motor, Class B insulation, automatic reset thermal overload protection, permanently lubricated sealed ball bearings |
9. Atilẹyin ọja ati Support
For detailed warranty information regarding your Fantech FG6 Inline Exhaust Fan, please refer to the warranty card or documentation included with your original purchase. You may also visit the official Fantech webojula fun awọn julọ lọwọlọwọ atilẹyin ọja ofin ati ipo.
For technical support, service inquiries, or to purchase replacement parts, please contact Fantech customer service directly. Ensure you have your product model number (FG6) and purchase date available when contacting support.
Fantech Oṣiṣẹ Webojula: www.fantech.net