Ọrọ Iṣaaju
This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Friedrich P12B Portable Room Air Conditioner. The P12B is a versatile 3-in-1 system, functioning as an air conditioner, dehumidifier, and fan, designed to cool rooms up to approximately 550 sq ft. It features dual-hose technology for enhanced cooling efficiency and a convenient 24-hour timer.

Iwaju view of the Friedrich P12B portable air conditioner, showcasing its compact and modern design. The unit is white with a grey top panel where the air vents are located.
Eto ati fifi sori
Ṣiṣi silẹ
Carefully remove the air conditioner from its packaging. Inspect the unit and all accessories for any signs of damage. Ensure all components listed in the packing list are present before proceeding with installation.
Ipo
Place the unit on a firm, level surface in a location that allows for proper air circulation. Ensure there is at least 20 inches (50 cm) of clear space around the unit for optimal performance. Position the unit near a window or sliding door for easy installation of the window exhaust kit.
Fifi sori Ohun elo Window
The Friedrich P12B utilizes a dual-hose system for efficient cooling. Install the adjustable window kit into your window opening. Connect both the intake and exhaust hoses to the corresponding ports on the back of the unit and then to the window adapter plate. Ensure all connections are secure to prevent air leakage, which can reduce efficiency.

This image illustrates the rear of the Friedrich P12B unit, showing the two flexible hoses extending from the unit to the window adapter plate. These hoses are crucial for the dual-hose system, which provides efficient cooling by drawing in fresh air and expelling hot air separately.
Isẹ
Ibi iwaju alabujuto ati Latọna jijin
The unit features an intuitive control panel with a digital display and various buttons for mode selection, temperature adjustment, fan speed, and timer settings. A remote control is also included for convenient operation from a distance. Ensure the remote control batteries are correctly installed.
Awọn ọna ṣiṣe
The Friedrich P12B offers four distinct operating modes to suit your climate control needs:
- Ipo Itura: Provides powerful air conditioning to lower room temperature.
- Ipo Ooru: (Heat pump model only) Functions as a heater to warm the room.
- Ipo Somimi: Removes excess moisture from the air without significant cooling.
- Ipo Ipele: Circulates air without engaging the cooling or heating functions.

This diagram highlights the four primary operating modes of the Friedrich P12B: Cooling, Heating (for heat pump models), Dehumidifying, and Fan-only operation. Each mode is designed for specific climate control needs.
Aago Išė
The 24-hour timer allows you to program the unit to turn on or off automatically at a specified time, providing convenience and energy savings.
Condensate Management
The unit features an auto-evaporation system, which typically eliminates the need to manually drain condensate in cooling mode. During heating mode, or in very humid conditions, a small amount of condensate may accumulate. The unit is equipped with an internal pump and a small tube to remove this condensate, provided the unit is on a completely level surface.
Itoju
Air Filter Cleaning
The Friedrich P12B is equipped with an antimicrobial air filter. For optimal performance and air quality, clean the air filter regularly, typically every two weeks or more often depending on usage and air quality. To clean, remove the filter, wash it with warm, soapy water, rinse thoroughly, and allow it to air dry completely before reinserting.
Ibi ipamọ igba
Before storing the unit for an extended period, ensure it is thoroughly cleaned and completely dry. Drain any remaining water from the unit. Store the unit upright in a dry, cool place, preferably in its original packaging, to protect it from dust and damage.
Laasigbotitusita
Refer to the table below for common issues and their potential solutions. If the problem persists after attempting these steps, contact customer support.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ni tan-an | No power supply; tripped circuit breaker; power cord not fully inserted. | Check power outlet; reset circuit breaker; ensure power cord is securely plugged in. |
| Itutu agbaiye ti ko to | Dirty air filter; blocked air intake/exhaust; room too large; windows/doors open; hoses not properly connected. | Clean air filter; clear obstructions; ensure room size is within specifications; close windows/doors; check hose connections. |
| Unit jẹ alariwo | Unit not on a level surface; internal components vibrating. | Ensure unit is on a stable, level surface. Some operational noise from the compressor is normal. |
| Omi jijo | Unit not level; drain plug not secured (if applicable). | Ensure unit is on a level surface. Check drain plug if manual drainage is required. |
Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | P12B |
| Agbara Itutu | 11600 BTU |
| Ipin Iṣe Agbara (EER) | 8.8 |
| Voltage | 115 Volts |
| Awọn iwọn (L x W x H) | 39.37 x 49.53 x 85.09 cm (15.5 x 19.5 x 33.5 inches) |
| Iwọn | 1.81 kg (4 lbs) |
| Àlẹmọ Iru | Antimicrobial Air Filter |
| Pataki Awọn ẹya ara ẹrọ | Remote control, 24-hour timer, Dual-hose system, Auto-evaporation |
| Awọn ọna ṣiṣe | Cool, Heat, Dehumidify, Fan |
Atilẹyin ọja ati Onibara Support
Friedrich products are manufactured to high-quality standards and are backed by a limited warranty. Please refer to the warranty card included with your product for specific terms and conditions. For technical assistance, troubleshooting not covered in this manual, or to inquire about warranty service, please contact Friedrich customer support through their official webaaye tabi alaye olubasọrọ ti a pese pẹlu iwe rira rẹ.
Always ensure you have your model number (P12B) and purchase date available when contacting support.





