Friedrich P12B

Ìwé Ìtọ́sọ́nà Olùlò Afẹ́fẹ́ Afẹ́fẹ́ Friedrich P12B

Awoṣe: P12B

Ọrọ Iṣaaju

This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Friedrich P12B Portable Room Air Conditioner. The P12B is a versatile 3-in-1 system, functioning as an air conditioner, dehumidifier, and fan, designed to cool rooms up to approximately 550 sq ft. It features dual-hose technology for enhanced cooling efficiency and a convenient 24-hour timer.

Iwaju view of the Friedrich P12B portable air conditioner, white with grey top panel.

Iwaju view of the Friedrich P12B portable air conditioner, showcasing its compact and modern design. The unit is white with a grey top panel where the air vents are located.

Eto ati fifi sori

Ṣiṣi silẹ

Carefully remove the air conditioner from its packaging. Inspect the unit and all accessories for any signs of damage. Ensure all components listed in the packing list are present before proceeding with installation.

Ipo

Place the unit on a firm, level surface in a location that allows for proper air circulation. Ensure there is at least 20 inches (50 cm) of clear space around the unit for optimal performance. Position the unit near a window or sliding door for easy installation of the window exhaust kit.

Fifi sori Ohun elo Window

The Friedrich P12B utilizes a dual-hose system for efficient cooling. Install the adjustable window kit into your window opening. Connect both the intake and exhaust hoses to the corresponding ports on the back of the unit and then to the window adapter plate. Ensure all connections are secure to prevent air leakage, which can reduce efficiency.

Ẹyìn view of Friedrich P12B portable air conditioner with dual hoses connected to a window adapter kit.

This image illustrates the rear of the Friedrich P12B unit, showing the two flexible hoses extending from the unit to the window adapter plate. These hoses are crucial for the dual-hose system, which provides efficient cooling by drawing in fresh air and expelling hot air separately.

Isẹ

Ibi iwaju alabujuto ati Latọna jijin

The unit features an intuitive control panel with a digital display and various buttons for mode selection, temperature adjustment, fan speed, and timer settings. A remote control is also included for convenient operation from a distance. Ensure the remote control batteries are correctly installed.

Awọn ọna ṣiṣe

The Friedrich P12B offers four distinct operating modes to suit your climate control needs:

  • Ipo Itura: Provides powerful air conditioning to lower room temperature.
  • Ipo Ooru: (Heat pump model only) Functions as a heater to warm the room.
  • Ipo Somimi: Removes excess moisture from the air without significant cooling.
  • Ipo Ipele: Circulates air without engaging the cooling or heating functions.
Diagram showing four operating modes: Cool, Heat, Dehumidify, and Fan for Friedrich portable air conditioner.

This diagram highlights the four primary operating modes of the Friedrich P12B: Cooling, Heating (for heat pump models), Dehumidifying, and Fan-only operation. Each mode is designed for specific climate control needs.

Aago Išė

The 24-hour timer allows you to program the unit to turn on or off automatically at a specified time, providing convenience and energy savings.

Condensate Management

The unit features an auto-evaporation system, which typically eliminates the need to manually drain condensate in cooling mode. During heating mode, or in very humid conditions, a small amount of condensate may accumulate. The unit is equipped with an internal pump and a small tube to remove this condensate, provided the unit is on a completely level surface.

Itoju

Air Filter Cleaning

The Friedrich P12B is equipped with an antimicrobial air filter. For optimal performance and air quality, clean the air filter regularly, typically every two weeks or more often depending on usage and air quality. To clean, remove the filter, wash it with warm, soapy water, rinse thoroughly, and allow it to air dry completely before reinserting.

Ibi ipamọ igba

Before storing the unit for an extended period, ensure it is thoroughly cleaned and completely dry. Drain any remaining water from the unit. Store the unit upright in a dry, cool place, preferably in its original packaging, to protect it from dust and damage.

Laasigbotitusita

Refer to the table below for common issues and their potential solutions. If the problem persists after attempting these steps, contact customer support.

IsoroOwun to le FaOjutu
Ẹka ko ni tan-anNo power supply; tripped circuit breaker; power cord not fully inserted.Check power outlet; reset circuit breaker; ensure power cord is securely plugged in.
Itutu agbaiye ti ko toDirty air filter; blocked air intake/exhaust; room too large; windows/doors open; hoses not properly connected.Clean air filter; clear obstructions; ensure room size is within specifications; close windows/doors; check hose connections.
Unit jẹ alariwoUnit not on a level surface; internal components vibrating.Ensure unit is on a stable, level surface. Some operational noise from the compressor is normal.
Omi jijoUnit not level; drain plug not secured (if applicable).Ensure unit is on a level surface. Check drain plug if manual drainage is required.

Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeP12B
Agbara Itutu11600 BTU
Ipin Iṣe Agbara (EER)8.8
Voltage115 Volts
Awọn iwọn (L x W x H)39.37 x 49.53 x 85.09 cm (15.5 x 19.5 x 33.5 inches)
Iwọn1.81 kg (4 lbs)
Àlẹmọ IruAntimicrobial Air Filter
Pataki Awọn ẹya ara ẹrọRemote control, 24-hour timer, Dual-hose system, Auto-evaporation
Awọn ọna ṣiṣeCool, Heat, Dehumidify, Fan

Atilẹyin ọja ati Onibara Support

Friedrich products are manufactured to high-quality standards and are backed by a limited warranty. Please refer to the warranty card included with your product for specific terms and conditions. For technical assistance, troubleshooting not covered in this manual, or to inquire about warranty service, please contact Friedrich customer support through their official webaaye tabi alaye olubasọrọ ti a pese pẹlu iwe rira rẹ.

Always ensure you have your model number (P12B) and purchase date available when contacting support.

Awọn iwe aṣẹ ti o jọmọ - P12B

Ṣaajuview Friedrich Portable Air Conditioner P09B & P12B Service and Parts Manual
This manual provides detailed service and parts information for Friedrich Portable Air Conditioners, models P09B and P12B. It includes troubleshooting guides, appearance diagrams, control panel functions, remote control operation, technical specifications, refrigerator system and wiring diagrams, an exploded view pẹlu awọn ẹya ara akojọ, ati atilẹyin ọja alaye.
Ṣaajuview Friedrich KUHL Room Air Conditioner Limited Warranty Information
This document details the limited warranty for Friedrich KUHL Room Air Conditioners, covering parts for the first year and the sealed refrigerant system for the second through fifth years. It outlines warranty applicability, limitations, how to obtain service, and proof of purchase requirements.
Ṣaajuview Friedrich Uni-Fit Nipasẹ-Odi Awọn amúlétutù: Smart, Idakẹjẹ, Itutu agbaiye to munadoko
Ṣe afẹri Friedrich Uni-Fit Series ti awọn amúlétutù yara-ogiri, ti o nfihan iṣakoso Wi-Fi ọlọgbọn, imọ-ẹrọ QuietMaster fun idakẹjẹ giga, ati iṣẹ ṣiṣe-agbara. Ṣawari awọn pato awoṣe ati awọn anfani fifi sori ẹrọ.
Ṣaajuview Friedrich Itanna Window Air kondisona Awọn ilana ti nṣiṣẹ
Awọn ilana iṣiṣẹ pipe fun Friedrich Itanna Window Air Conditioners, aabo ibora, fifi sori ẹrọ, iṣẹ ṣiṣe, itọju, ati laasigbotitusita fun awọn awoṣe CCW15B10A, CCW18B30A, CCW24B30A, CEW18B33A, ati CEW24B33A.
Ṣaajuview Friedrich Chill Premier Series Room Air Conditioners Installation and Operation Manual
Comprehensive installation and operation manual for Friedrich Chill Premier Series Room Air Conditioners, covering safety, installation, operation, troubleshooting, and warranty information for models CCW15B10B, CCW18B30B, CCW24B33B, CEW18B33B, and CEW24B33B.
Ṣaajuview Ìwé Ìtọ́sọ́nà Fífi sori Ẹ̀rọ Afẹ́fẹ́ Friedrich àti Ìṣiṣẹ́
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of Friedrich MWM09Y1J, MWM12Y1J, MRM09Y1J, and MRM12Y1J air conditioning units. It covers safety precautions, remote control functions, and service information.