The Wayne CWS100 1-horsepower shallow well jet pump is designed for wells up to 90-feet deep. It is capable of pumping up to 560 gallons per hour at a 5-foot depth when operating at 50 PSI. This pump is built with a durable cast iron volute and features a dedicated priming port for easy filling.

Wayne CWS100 Convertible Well Pump

Image: The Wayne CWS100 Convertible Well Pump, showcasing its black cast iron body and motor assembly.

Key Awọn ẹya ara ẹrọ

Awọn ilana iṣeto

Proper installation is crucial for the optimal performance and longevity of your Wayne CWS100 pump. Ensure all local plumbing and electrical codes are followed. The pump is designed for shallow well applications up to 90 feet deep.

1. Site Selection and Mounting

Choose a dry, well-ventilated location as close to the well as possible. Mount the pump on a solid, level surface to minimize vibration and noise. Use appropriate bolts to secure the pump base.

2. Plumbing Awọn isopọ

Connect the suction line (1-1/4 inch NPT) from the well to the pump's suction port. Connect the discharge line (3/4 inch NPT) from the pump to your household plumbing system. Ensure all connections are watertight using thread sealant. Consider increasing suction plumbing diameter or decreasing pipe friction for improved performance.

3. Itanna onirin

The pump is factory-set for 240V operation. If 120V operation is desired, consult the wiring diagram provided in the full user manual for proper conversion. Connect the pump to a dedicated, properly grounded electrical circuit with appropriate overcurrent protection. All electrical work should be performed by a qualified electrician.

4. Ṣíṣe àtúnṣe Pọ́ọ̀pù

Before initial operation, the pump must be primed. Remove the priming plug from the dedicated priming port on the volute. Fill the pump casing and suction line completely with water until it overflows. Replace the priming plug securely. This step is critical for jet pump operation.

Awọn ilana Iṣiṣẹ

Once properly installed and primed, the Wayne CWS100 pump operates automatically based on system pressure.

1. Ibẹrẹ ibẹrẹ

After priming, restore power to the pump. The pump will start and build pressure. The pressure switch is pre-set to turn the pump on at 30 PSI and off at 50 PSI. Allow the pump to run until it reaches the cut-off pressure and shuts off automatically.

2. Isẹ deede

The pump will cycle on and off as water is used and system pressure drops below the cut-in setting. Ensure there are no leaks in the plumbing system, as this can cause the pump to short cycle (turn on and off frequently).

3. Títìpa

For temporary shutdown, simply turn off the power to the pump at the circuit breaker. For extended periods of non-use, especially in freezing temperatures, drain the pump and plumbing lines completely to prevent damage.

Itoju

Regular maintenance helps ensure the longevity and efficient operation of your well pump.

Laasigbotitusita

This section provides basic troubleshooting steps for common issues. For more complex problems, consult a qualified professional or refer to the complete user manual.

IsoroOwun to le FaOjutu
Pump runs but no water or low pressureLoss of prime, air leak in suction line, low well water level, clogged impeller.Re-prime the pump. Check all suction line connections for leaks. Verify well water level. Inspect and clean impeller if accessible.
Pump short cycles (turns on/off frequently)Waterlogged pressure tank, air leak in system, pressure switch malfunction.Check pressure tank air charge. Inspect plumbing for leaks. Consult a technician for pressure switch issues.
Pump ko bẹrẹNo power, tripped circuit breaker, faulty motor, seized pump.Check power supply and circuit breaker. Consult a qualified electrician or pump technician.

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
BrandWayne
Nọmba awoṣeCWS100
Agbara ẹṣin1 HP
Oṣuwọn Sisan ti o pọju588 gallons per hour (at 50 PSI)
Max gbígbé GigaTiti di 90 ẹsẹ
Voltage120V/240V (Meji Voltage, factory set for 240V)
Iwon Ifijiṣẹ3/4 inch NTT
Iwon afamora1-1 / 4 inch NPT
Iwon Wakọ1 inch
Titẹ Yipada Eto30-50 PSI (pre-set)
Ohun eloSimẹnti Irin
Iwọn Nkan40 iwon
Ọja Mefa14 x 9 x 8.75 inches
UPC040066105974

Alaye atilẹyin ọja

The Wayne CWS100 Convertible Well Pump comes with a 3-Odun lopin atilẹyin ọja covering parts only. For specific terms and conditions, please refer to the official warranty documentation included with your product or contact Wayne customer support.

Atilẹyin ati Alaye siwaju sii

For detailed diagrams, advanced troubleshooting, or to purchase replacement parts, please refer to the complete user manual available as a PDF document. You can often find this on the manufacturer's official webaaye tabi nipasẹ alagbata ti o ti ra ọja naa.

For direct support, you may visit the official Wayne store or contact their customer service department.
Visit the Wayne Store on Amazon

Ẹya PDF ti itọnisọna olumulo tun wa fun igbasilẹ: Ṣe igbasilẹ Itọsọna olumulo (PDF)

Awọn iwe aṣẹ ti o jọmọ - CWS100

Ṣaajuview WAYNE CWS Series Iyipada Daradara Jet Awọn ọna Omi: Awọn ilana iṣiṣẹ ati Afọwọṣe Awọn apakan
Awọn ilana iṣiṣẹ okeerẹ, itọnisọna awọn ẹya, ati itọsọna fifi sori ẹrọ fun WAYNE CWS Series Convertible Well Jet Pump Water Systems. Ni wiwa ni pato, ailewu, fifi sori ẹrọ, isẹ, itọju, ati laasigbotitusita.
Ṣaajuview WAYNE WLS Series Lawn Sprinkler Pump: Operating Instructions and Parts Manual
This manual provides comprehensive operating instructions, installation guides, maintenance procedures, troubleshooting tips, and parts lists for the WAYNE WLS150 and WLS200 Lawn Sprinkler Pumps. Learn how to safely and effectively use your WAYNE pump.
Ṣaajuview WAYNE PLS100 Portable Lawn Sprinkler and Multi-Use Pump: Operating Instructions and Manual
Comprehensive operating instructions, installation guide, maintenance, and troubleshooting for the WAYNE PLS100 Portable Lawn Sprinkler and Multi-Use Pump. Features specifications, performance data, safety warnings, and limited warranty information.
Ṣaajuview Wayne Submersible Sump System Installation Guide and Warranty
Comprehensive installation guide and warranty information for Wayne Submersible Sump Systems, including primary and backup pump operation, unpacking, and product specifications.
Ṣaajuview Wayne Submersible Sump Pumps: Installation, Operation, and Maintenance Manual
Comprehensive installation manual for Wayne submersible sump pumps, covering operation, safety, troubleshooting, and limited warranty information. Includes specifications and performance data for various models.
Ṣaajuview Wayne Submersible Sump Pumps: Installation, Operation, and Parts Manual
Comprehensive installation, operation, troubleshooting, and warranty guide for Wayne Submersible Sump Pumps, including specifications, performance data, and maintenance instructions.