ESAB 0781-0589

ESAB SR-461B-510 LPG Cylinder Gas Regulator Instruction Manual

Awoṣe: 0781-0589

1. Ifihan

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of your ESAB SR-461B-510 Industrial Gas Regulator. This single-stage regulator is designed for use with LP Gas cylinders, featuring a CGA-510 inlet connection and a 9/16 In.-18 M LH outlet connection.

Please read this manual thoroughly before attempting to install or operate the regulator. Retain this manual for future reference.

1.1. Alaye Aabo

IKILO: Misuse of this product may cause explosion and personal injury. Always read and understand all ASME-B40.100 standards and apparatus installation/operating instructions before using.

This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (California Proposition 65 warning).

  • Always ensure proper ventilation when working with LP gas.
  • Never use oil or grease on regulator or cylinder connections.
  • Inspect the regulator and connections for damage before each use.
  • Use only with compatible LP gas cylinders and connections.
  • Do not modify the regulator in any way.

1.2. Package Awọn akoonu

  • ESAB SR-461B-510 Regulator Unit
  • Itọsọna Akọtọ (iwe yii)

2. Eto ati fifi sori

Follow these steps for safe installation of the regulator to an LP gas cylinder.

  1. Ensure the cylinder valve is closed and the regulator adjusting screw is fully backed out (turned counter-clockwise until loose).
  2. Inspect the cylinder valve outlet and regulator inlet connection (CGA-510) for any damage or debris.
  3. Connect the regulator inlet nut to the cylinder valve outlet. The CGA-510 connection is designed for LP gas. Tighten securely with a wrench.
  4. Connect the outlet hose (not included) to the regulator's 9/16 In.-18 M LH outlet connection. Ensure this connection is also tight.
  5. Perform a leak test using a suitable leak detection solution on all connections before opening the cylinder valve.
ESAB SR-461B-510 LPG Cylinder Gas Regulator with two gauges and a T-handle adjusting screw.

Nọmba 1: ESAB SR-461B-510 LPG Cylinder Gas Regulator. This image displays the brass regulator body, two pressure gauges, and a T-handle adjusting screw. The inlet connection (CGA-510) is visible on the right, designed for LP gas cylinders. The left gauge, which in this image shows a scale for Acetylene (0-15 psi), would indicate the delivery pressure for LPG. The right gauge indicates the cylinder pressure (0-400 psi).

3. Awọn ilana Iṣiṣẹ

Once the regulator is securely installed and leak-tested, follow these steps to operate.

  1. Slowly open the cylinder valve. The inlet gauge (right gauge, 0-400 psi) will indicate the cylinder pressure.
  2. Turn the regulator adjusting screw (T-handle) clockwise to increase the delivery pressure. The delivery pressure gauge (left gauge, 0-60 psig) will show the regulated pressure. Adjust to the desired working pressure, typically within the 2 to 40 psig range for this model.
  3. Once the desired pressure is set, you can begin using the LP gas.
  4. To shut down, first close the cylinder valve.
  5. Allow the gas in the system to bleed off until both gauges read zero.
  6. Turn the regulator adjusting screw counter-clockwise until it is loose to relieve spring tension.

The regulator is designed for a flow rate of approximately 2500 SCFH (Standard Cubic Feet per Hour).

4. Itọju

Regular maintenance ensures the longevity and safe operation of your regulator.

  • Ayewo: Before each use, visually inspect the regulator for any signs of damage, such as dents, cracks, or worn threads. Check gauges for proper function.
  • Ninu: Keep the regulator clean and free from oil, grease, or other contaminants. Use a clean, dry cloth. Do not use harsh chemicals.
  • Idanwo Leak: Periodically perform a leak test on all connections, even if no issues are suspected.
  • Ibi ipamọ: When not in use, store the regulator in a clean, dry place, disconnected from the cylinder.

Do not attempt to repair the regulator yourself. Refer all repairs to qualified personnel or contact ESAB customer support.

5. Laasigbotitusita

Abala yii n ṣalaye awọn ọran ti o wọpọ ti o le ba pade.

  • Ko si sisan gaasi:
    • Ensure the cylinder valve is fully open.
    • Check if the cylinder contains gas.
    • Verify the regulator adjusting screw is turned clockwise to set a delivery pressure.
    • Inspect for blockages in the hose or equipment.
  • Pressure Not Holding:
    • Perform a leak test on all connections (cylinder, regulator inlet, regulator outlet, hose).
    • Rii daju pe gbogbo awọn asopọ ti di wiwọ ni aabo.
    • If leaks persist or the regulator itself is suspected, discontinue use and contact support.
  • Inaccurate Gauge Readings:
    • Gauges are factory calibrated. If readings appear consistently incorrect, the gauge may be faulty. Discontinue use and contact support.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact ESAB customer support.

6. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣe0781-0589 (SR-461B-510)
Olutọju IruIndustrial Gas Regulator, Single Stage
Gas ServiceGaasi LP (LPG)
Asopọ agbawọleCGA-510
Asopọ iṣan9/16 In.-18 M LH
Delivery Pressure Range2 to 40 pg
Delivery Pressure Gauge60 psig (2-1/2 In. Gauge Size)
Inlet Gauge400 psig (2-1/2 In. Gauge Size)
Oṣuwọn Sisan (Isunmọ.)2500 SCFH
Ohun eloIdẹ eke
Lapapọ Gigun7-1/4 Ni.
Ọja Mefa6 x 7 x 7 inches
Iwọn Nkan5.13 iwon
OlupeseVictor Technologies (ESAB)
Ilu isenbaleOrilẹ Amẹrika

7. Atilẹyin ọja ati Support

For warranty information, technical support, or service inquiries, please contact ESAB customer service directly. Refer to the official ESAB webAaye tabi apoti ọja fun awọn alaye olubasọrọ tuntun julọ.

When contacting support, please have your model number (0781-0589) and purchase information available.

Awọn iwe aṣẹ ti o jọmọ - 0781-0589

Ṣaajuview Ìtọ́sọ́nà Ìbẹ̀rẹ̀ Kíákíá fún Torch ESAB PP 350w - Ṣíṣeto àti Ìṣiṣẹ́
Ìtọ́sọ́nà tó ṣe ṣókí fún ṣíṣètò àti ṣíṣiṣẹ́ fìtílà ìsopọ̀mọ́ra ESAB PP 350w, pẹ̀lú ìsopọ̀mọ́ra, àtúnṣe, àti ìwífún nípa ààbò.
Ṣaajuview ESAB TRACFINDER kẹkẹ: Betjeningsvejledning og Teknisk Alaye
Denne betjeningsvejledning olufun detaljerede instruktioner digba fifi sori, fiseete, vedligeholdelse og fejlfinding af ESAB TRACFINDER kẹkẹ svejsetraktor. Lær om tekniske specifikationer, sikkerhedsprocedurer og tilbehør.
Ṣaajuview Ìwé Ìtọ́ni ESAB LAF 1001 / LAF 1001M - Ìtọ́ni Orísun Agbára Alurinmorin
Ìwé ìtọ́ni tó péye fún àwọn orísun agbára ìsopọ̀mọ́ra onípele mẹ́ta tí a ń ṣàkóso láti ọ̀nà jíjìn ESAB LAF 1001 àti LAF 1001M, tí ó bo ìfisílé, iṣẹ́, ìtọ́jú, àti ààbò fún àwọn ohun èlò ìsopọ̀mọ́ra oníṣẹ́ ẹ̀rọ.
Ṣaajuview Guía de funcionamiento del TRACFINDER WHEEL de ESAB
Afowoyi de funcionamiento y guía de instalación para el carro de soldadura autónomo ESAB TRACFINDER WHEEL. Cubre especificaciones técnicas, operaciones, mantenimiento y solución de problemas.
Ṣaajuview ESAB TRACFINDER RAIL: Manual de Operação e Instalação
Este manual fornece instruções detalhadas sobre a instalação, operação, segurança, manutenção e solução de problemas do sistema de soldagem automatizada ESAB TRACFINDER RAIL, projetado para aplicações industriais.
Ṣaajuview Manual de Instrucciones ESAB TRACFINDER WHEEL
Manual de instrucciones completo para el carro de soldadura ESAB TRACFINDER WHEEL. Cubre instalación, operación, panel de control, mantenimiento, resolución de averías y especificaciones técnicas.