Ọrọ Iṣaaju
The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.
Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.
Alaye Aabo
IKILO: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Always disconnect power before inspecting or working on electrical connections.
- Rii daju pe gbogbo awọn asopọ waya wa ni aabo ati idabobo daradara.
- Do not use this plug with damaged or frayed cords.
- Ọjà yìí ní àwọn kẹ́míkà tí Ìpínlẹ̀ California mọ̀ pé ó lè fa àrùn jẹjẹrẹ àti àbùkù ìbímọ tàbí àwọn ìpalára mìíràn nínú ìbímọ (ìkìlọ̀ Ìròyìn 65). Fọ ọwọ́ rẹ lẹ́yìn tí o bá fi ọwọ́ mú un.
Eto ati fifi sori
This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.
Awọn irinṣẹ ti a beere:
- Phillips ori screwdriver
- Waya strippers
- Utility knife (optional, for outer jacket)
Awọn itọnisọna wiwọ:
- Prepare the Cord: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
- Disassemble the Plug: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
- So awọn Wires pọ: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
- Waya Ejò Alawọ ewe/Ifipa: Sopọ si awọn alawọ ewe (grounding) screw terminal.
- Waya funfun: Sopọ si awọn fadaka (neutral) screw terminal.
- Waya Dudu: Sopọ si awọn idẹ (hot) screw terminal.
- Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
- Reassemble the Plug: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Aworan: Isunmọ view of the internal wiring chambers, showing isolated conductors and screw terminals.
Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.
Awọn ilana Iṣiṣẹ
Once properly wired, the Leviton 8215-PLC plug is ready for use.
- Sopọ si Agbara: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
- Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
- Ge asopọ: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.
Itoju
Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.
- Ayewo Igbakọọkan: Regularly check the plug and cord for any signs of damage, such as cracks, frayed insulation, bent blades, or discoloration. If any damage is observed, discontinue use and replace the plug or cord as necessary.
- Ninu: Disconnect the plug from the power source before cleaning. Wipe the exterior of the plug with a dry, clean cloth. Do not use liquid cleaners or solvents, as these may damage the material or internal components.
- Ṣayẹwo Asopọmọra: If the plug is frequently moved or subjected to stress, periodically check the tightness of the assembly screws and cord clamp screws to ensure secure connections.
Laasigbotitusita
If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:
- Atọka LED Ko tan:
- Ensure the plug is fully inserted into a live receptacle.
- Check the circuit breaker or fuse for the outlet to ensure power is supplied.
- Verify the wiring connections inside the plug are secure (refer to Setup and Installation).
- Ṣayẹwo okun agbara fun eyikeyi ibajẹ.
- Loose Connection or Intermittent Power:
- Disconnect power and re-open the plug to check all wire terminal screws for tightness.
- Ensure the cord clamp is securely tightened to prevent strain on the internal connections.
- Bibajẹ ti ara: If the plug body, blades, or cord show signs of physical damage, replace the plug immediately.
Awọn pato
| Nọmba awoṣe | 8215-PLC |
| Ampigba | 15 Amps |
| Voltage | 125 Volts |
| NEMA iṣeto ni | 5-15P |
| Ọpá / onirin | 2 Pole, 3 Wire Grounding |
| Iwọn ọja | Ile-iwosan ite |
| Ohun elo | Super Tough Nylon (Body), Thermoplastic (Back Cover) |
| Àwọ̀ | Sihin |
| Itọkasi agbara | LED boolubu |
| Awọn ifọwọsi | UL 498, CSA C22.2, NOM 057 |
| Iwọn Nkan | 0.01 iwon |
| Ọja Mefa | 9.38 x 7.13 x 9 inches |
Alaye atilẹyin ọja
This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.
Onibara Support
For technical assistance, product inquiries, or further support, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the Leviton webaaye tabi apoti ọja.
Leviton Webojula: www.leviton.com