Ọrọ Iṣaaju
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump, Model 4117301. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.
Alaye Aabo
Always adhere to local regulations and safety standards during installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Rii daju pe ipese agbara ti ge asopọ ṣaaju fifi sori eyikeyi, itọju, tabi iṣẹ atunṣe.
- Installation and electrical connections must be performed by qualified personnel only.
- Do not operate the pump if it is damaged or if the electrical connections are exposed.
- This pump is designed for residential closed-loop water heating systems. It is not approved for domestic hot water awọn ohun elo.
- Dáàbò bo fifa omi kuro ninu otutu otutu ti o tutu.
Ọja Pariview
The Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump is designed for efficient circulation in heating systems. Key features include:
- Iṣiṣẹ to gaju: Optimized for energy savings in circulating applications.
- Iwọn otutu: Operates effectively within a temperature range of 14°F to 230°F (-10°C to 110°C).
- Iṣe: Provides a maximum head of 16 feet with a maximum flow rate of 16 GPM.
- Fifi sori ẹrọ Rọ: Features a flange that can be rotated 90 degrees for versatile mounting.
- Asopọ ti o rọrun: Equipped with quick-connect electrical terminals for simplified wiring.

Figure 1: Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump. This image shows the pump from a slightly elevated side angle, highlighting its compact design, the green pump housing, and the grey and black control unit with a red dial and energy efficiency indicator.
Fifi sori ẹrọ ati Eto
Follow these steps for proper installation of the circulating pump:
- Iṣagbesori: Securely mount the pump in the desired position within the closed-loop heating system. The flange can be rotated 90 degrees to accommodate various pipe orientations.
- Pipin: Connect the pump to the heating system piping. Ensure all connections are watertight and free of leaks.
- Asopọmọra itanna:
- Ensure the main power supply is OFF.
- Connect the 115-Volt power supply to the quick-connect electrical terminals. Refer to the wiring diagram provided with the pump for specific connections.
- Rii daju pe gbogbo awọn asopọ itanna wa ni aabo ati idabobo daradara.
- Nkún eto: Fill the heating system with water and bleed any air from the system. Proper air removal is crucial for efficient pump operation.
- Ṣayẹwo akọkọ: Before powering on, double-check all connections and ensure the system is properly filled and free of air.
Awọn ilana Iṣiṣẹ
Once installed and connected, operate the pump as follows:
- Agbara Tan: Restore power to the pump. The pump will typically start in an automatic mode.
- Aṣayan Ipo: Use the control dial on the pump's interface to select the desired operating mode. The Stratos ECO series often features automatic adjustment to system requirements, but manual settings for constant pressure or proportional pressure may be available. Consult the markings on the control unit for specific options.
- Abojuto: Observe the pump's operation and the system's performance. The integrated display or indicators will show the current operating status and energy consumption.
Itoju
Regular maintenance ensures the longevity and optimal performance of your Wilo pump.
- Ayewo Ọdọọdun: Annually inspect the pump for any signs of wear, leaks, or unusual noises.
- Dídára Omi Ètò: Ensure the heating system water quality is maintained according to manufacturer recommendations to prevent corrosion and scale buildup.
- Ninu: Jẹ́ kí òde ẹ̀rọ fifa omi náà mọ́, kí ó sì wà ní mímọ́, kí ó má sì sí eruku àti ìdọ̀tí. Má ṣe lo àwọn ohun èlò ìfọmọ́ tí a fi ń pa ara.
- Ẹjẹ afẹfẹ: Periodically check and bleed air from the heating system to prevent cavitation and ensure smooth operation.
Laasigbotitusita
Tí o bá ní ìṣòro pẹ̀lú píńpù rẹ, wo àwọn ìṣòro àti ìdáhùn tó wọ́pọ̀ wọ̀nyí:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Fifa ko nṣiṣẹ | No power supply; Motor jammed; Electrical fault | Check power connection and circuit breaker; Consult a qualified technician for motor or electrical issues. |
| Fifa ṣiṣe ariwo dani | Air in system; Cavitation; Bearing wear | Bleed air from the system; Ensure adequate water pressure; Contact service if noise persists. |
| Àìtó ìṣàn/títẹ̀ tó | Air in system; Incorrect operating mode; Clogged impeller | Bleed air; Adjust operating mode; Inspect and clean impeller (power off first). |
If the problem persists after attempting these solutions, contact Wilo customer support or a certified service technician.
Awọn pato
| Iwa | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | 4117301 |
| Brand | Wilo |
| O pọju Ori | 16 Ẹsẹ |
| Oṣuwọn Sisan ti o pọju | 16 GPM |
| Voltage | 115-Fọlti |
| Iwọn otutu | 14°F si 230°F (-10°C si 110°C) |
| Ohun elo | Residential closed-loop water heating systems (Not for domestic hot water) |
| Iwọn Nkan | 3 kg 580 g |
| Package Mefa | 23.37 x 22.61 x 22.35 cm |
Atilẹyin ọja ati Support
The Wilo Stratos ECO 16-Feet High Efficiency Circulating Pump comes with a 3-odun atilẹyin ọja. For warranty claims, technical support, or service inquiries, please contact Wilo customer service. Ensure you have your model number (4117301) and purchase details available when contacting support.
For the most up-to-date contact information, please visit the official Wilo webaaye tabi tọka si iwe ti o wa pẹlu ọja rẹ.





