The Intermatic MIL72ASTUZH-120 is a robust 24-hour electromechanical time control designed for precise scheduling of electrical circuits. This timer module is suitable for light-duty commercial applications, including lighting control, HVACR systems, pumps, motors, and general-purpose electrical circuits. It features a manual override function and can be mounted on a surface or DIN rail, making it versatile for various installations. This manual provides detailed instructions for the safe and effective use of your time control.

Alaye Aabo

WARNING: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse before installation or servicing. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes.

  • Má ṣe kọjá ìwọ̀n iná mànàmáná tí a sọ fún ẹ̀rọ náà.
  • Rii daju pe gbogbo awọn asopọ onirin wa ni aabo ati ti ya sọtọ daradara.
  • This device contains a non-replaceable Nickel Metal Hydride battery. Do not attempt to replace it.
  • Jeki ẹrọ naa kuro lati ọrinrin ati awọn iwọn otutu to gaju.

Ọja Pariview

The MIL72ASTUZH-120 timer features a 24-hour dial with adjustable ON/OFF trippers (pins) for setting precise schedules. The clear cover protects the dial and internal components while allowing visual inspection of the current time and program.

Intermatic MIL72ASTUZH-120 24-Hour Electromechanical Time Control

olusin 1: Iwaju view of the Intermatic MIL72ASTUZH-120 timer. The image displays the white casing with a clear protective cover over the black 24-hour dial. The dial features white markings for hours (12, 6, 9) and smaller increments, along with 'am' and 'pm' indicators. The center of the dial shows the clock hands and the 'GRASSLIN' brand name at the bottom. The outer edge of the dial has numerous small white pins, which are used for setting the ON/OFF times.

Awọn eroja pataki:

  • Ipese wakati 24: Displays the current time and allows for programming.
  • Time-Setting Hands: Fi àkókò tó wà lọ́wọ́lọ́wọ́ hàn.
  • ON/OFF Trippers (Pins): Small, movable pins around the dial used to set the desired ON and OFF times.
  • Yipada Yipada Afọwọṣe: Allows temporary or permanent override of the programmed schedule.
  • Idina Iduro: For electrical connections (located internally, accessed during installation).

Eto ati fifi sori

The MIL72ASTUZH-120 can be mounted on a surface or a DIN rail. Ensure the mounting location is dry, protected from direct sunlight, and within the specified operating temperature range.

Awọn igbesẹ fifi sori ẹrọ:

  1. Ge Agbara: Before beginning any work, ensure that power to the circuit is completely disconnected at the main service panel (circuit breaker or fuse box). Verify with a voltage idanwo.
  2. Iṣagbesori:
    • Oke Oke: Use appropriate screws to secure the timer to a flat, stable surface.
    • DIN Rail Oke: Snap the timer onto a standard 35mm DIN rail.
  3. Asopọmọra: Refer to the wiring diagram provided with the product packaging. Connect the 120 VAC power supply and the load wires to the appropriate terminals on the timer's terminal block. Ensure all connections are tight and secure.
  4. Pade Ideri: Once wiring is complete and verified, securely close the protective cover of the timer.
  5. Pada Agbara pada: Restore power to the circuit at the main service panel.

Awọn ilana Iṣiṣẹ

1. Setting the Current Time:

  1. Rotate the 24-hour dial clockwise until the current time aligns with the small arrow or mark on the stationary part of the timer housing.
  2. Ensure you distinguish between AM and PM hours (e.g., 3 PM is 15:00 on a 24-hour dial).

2. Programming ON/OFF Times:

The dial has small, movable trippers (pins) around its circumference. Each tripper represents a specific time interval.

  • To set an ON time: Push an 'ON' tripper (typically a darker or larger pin) towards the center of the dial at the desired ON time.
  • To set an OFF time: Push an 'OFF' tripper (typically a lighter or smaller pin) away from the center of the dial at the desired OFF time.
  • Multiple ON/OFF cycles can be programmed within the 24-hour period.

3. Yiyọ afọwọṣe:

The timer includes a manual override switch, typically a small lever or button, that allows you to temporarily or permanently override the programmed schedule.

  • Consult the specific markings on your timer for the override positions (e.g., 'ON', 'OFF', 'AUTO').
  • Moving the switch to 'ON' will keep the load continuously on, regardless of the program.
  • Moving the switch to 'OFF' will keep the load continuously off.
  • Moving the switch to 'AUTO' or a similar position will return control to the programmed schedule.

Itoju

The MIL72ASTUZH-120 is designed for minimal maintenance. Regular cleaning and periodic checks are recommended.

  • Ninu: Wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Ayewo: Periodically check the wiring connections for tightness and signs of wear or damage. Ensure the protective cover is securely closed.
  • Batiri: The internal Nickel Metal Hydride battery is non-replaceable and designed for the life of the unit. No user maintenance is required for the battery.

Laasigbotitusita

If you experience issues with your MIL72ASTUZH-120 timer, consult the following table:

IsoroOwun to le FaOjutu
Timer does not operate / Load does not turn ON/OFFNo power to the timer; Incorrect wiring; Manual override engaged; Trippers not set correctly.Check circuit breaker/fuse; Verify wiring connections; Ensure manual override is in 'AUTO' position; Re-check ON/OFF tripper placement.
Timer runs but load does not activateLoad wiring issue; Load device malfunction; Manual override engaged.Check load wiring; Test load device independently; Ensure manual override is in 'AUTO' position.
Timer makes unusual noiseTi abẹnu darí oro.Disconnect power immediately. Contact a qualified electrician or Intermatic customer support. Do not attempt to repair.

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Nọmba awoṣeMIL72ASTUZH-120
Voltage120 VAC
Igbohunsafẹfẹ60 Hz
Aago Iru24-Hour Electromechanical
IṣagbesoriSurface / DIN Rail
Ohun eloIrin
Àwọ̀Nickel
Iwọn Nkan8 iwon
Ọja Mefa5.75 x 3.25 x 3.25 inches
Ti abẹnu BatiriNickel Metal Hydride (Non-replaceable)

Atilẹyin ọja ati Support

For specific warranty information and technical support, please refer to the documentation included with your product at the time of purchase or visit the official Intermatic webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.

For further assistance, you may contact Intermatic customer service directly. Contact details are typically available on the manufacturer's webaaye tabi apoti ọja.

Awọn iwe aṣẹ ti o jọmọ - MIL72ASTUZH-120

Ṣaajuview Intermatic GM40AV Series Electromechanical Commercial Time Switch: Installation and Operation Manual
Comprehensive installation, operation, and programming guide for the Intermatic GM40AV Series electromechanical commercial time switches. Includes electrical ratings, wiring diagrams, and warranty information.
Ṣaajuview Intermatic WHQ Series 40A Awọn Aago Igbona Omi pẹlu Afẹyinti Batiri - Fifi sori ẹrọ ati Itọsọna Iṣiṣẹ
Alaye ni kikun lori Intermatic WHQ Series 24-Hour/7-Day electromechanical water heater time, pẹlu awọn ẹya ara ẹrọ, awọn pato, itọsọna fifi sori ẹrọ, awọn ilana siseto, ati alaye atilẹyin ọja. Apẹrẹ fun ibugbe, iṣowo, ati lilo ile-iṣẹ.
Ṣaajuview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Comprehensive details on Intermatic T170, T1400, and T1800 Series 24-Hour Electromechanical Time Switches, covering features, specifications, ratings, model variations, and wiring diagrams for commercial, industrial, and residential applications.
Ṣaajuview Intermatic Grässlin CP924 Electronic Plug-In Timer: Features & Operating Instructions
Comprehensive guide to the Intermatic Grässlin CP924 electronic plug-in timer. Learn about its features, specifications, and how to program ON/OFF times for residential appliances.
Ṣaajuview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.
Ṣaajuview Intermatic T103 24-Hour Dial Time Switch: Installation and Operation Manual
Detailed guide for the Intermatic T103 24-Hour Dial Time Switch, covering specifications, safety warnings, wiring instructions, programming, and operation. Suitable for indoor use with 120/208/240 VAC power.