Sensọ Eto RTS151KEY

System Sensor RTS151KEY Remote Test and Reset Station with Key

Àwòṣe: RTS151KEY

1. Ọja Ipariview

The System Sensor RTS151KEY is a remote test and reset station designed for use with compatible duct smoke detectors. This device allows for convenient testing and resetting of the associated smoke detector from a remote location, eliminating the need to access the detector directly within the ductwork. It features a key-operated switch for secure operation.

System Sensor RTS151KEY Remote Test and Reset Station with Key

olusin 1.1: Iwaju view of the System Sensor RTS151KEY Remote Test and Reset Station, showing the keyhole, reset, and test labels.

2. Alaye Aabo pataki

IKILO:

  • Installation and wiring must be performed by qualified personnel in accordance with all local codes and authorities having jurisdiction.
  • Ge asopọ agbara ṣaaju ṣiṣe tabi fifi sori ẹrọ.
  • This device is part of a fire alarm system. Proper functioning is critical for life safety. Do not modify or tamper pẹlu ẹrọ.
  • Ensure all connections are secure and correct as per the wiring diagrams.
  • Do not paint this fire alarm device.

3. Package Awọn akoonu

Daju pe gbogbo awọn nkan wa ati pe ko bajẹ lori ṣiṣi package naa:

  • System Sensor RTS151KEY Remote Test and Reset Station
  • Keys (typically two)
  • Installation and Wiring Instructions (manual)
Two keys for the RTS151KEY remote station

Figure 3.1: Included keys for operating the RTS151KEY station.

Instruction manual with wiring diagrams for System Sensor RTS151KEY

Olusin 3.2: Example of the included installation and wiring instructions.

4. Fifi sori ẹrọ ati Wiring

The RTS151KEY is designed for surface mounting. Ensure the mounting location is easily accessible for testing and resetting, and is within the specified wiring distance from the associated duct smoke detector.

4.1 Iṣagbesori

  1. Select a suitable mounting location, typically near the duct smoke detector or in a control room.
  2. Secure the backplate of the RTS151KEY to the wall or surface using appropriate screws.
  3. Ensure the device is mounted securely and level.

4.2 Onirin

Refer to the wiring diagram provided with your specific duct smoke detector and the RTS151KEY manual for precise connections. The RTS151KEY typically connects to the detector's remote test/reset terminals and power terminals.

Pada view of System Sensor RTS151KEY showing wiring terminals and labels

olusin 4.1: Ẹyìn view of the RTS151KEY, showing terminal block connections for wiring.

  • Connect the power supply (DC ONLY) to the designated terminals.
  • Connect the remote test/reset wires from the duct smoke detector to the corresponding terminals on the RTS151KEY.
  • Ensure all wiring connections are tight and properly insulated.
  • After wiring, attach the front cover of the RTS151KEY to the mounted backplate.

5. Awọn ilana Iṣiṣẹ

The RTS151KEY provides remote testing and resetting capabilities for compatible duct smoke detectors.

5.1 Testing the Duct Smoke Detector

  1. Insert the key into the keyhole on the RTS151KEY.
  2. Yi bọtini si awọn Idanwo position. This will activate the test function of the connected duct smoke detector.
  3. Observe the alarm indicator on the RTS151KEY (if present) and/or the main fire alarm control panel for confirmation of the alarm.
  4. Once the test is complete, return the key to the center (normal) position and remove it.

5.2 Resetting the Duct Smoke Detector

  1. After an alarm condition or a test, the duct smoke detector may need to be reset.
  2. Insert the key into the keyhole on the RTS151KEY.
  3. Yi bọtini si awọn Tunto position. This will initiate a reset sequence for the connected duct smoke detector.
  4. Hold the key in the RESET position for a few seconds, then return it to the center (normal) position and remove it.
  5. Confirm that the alarm condition has cleared on the main fire alarm control panel.

6. Itọju

The RTS151KEY is a low-maintenance device. Regular maintenance should focus on ensuring its physical integrity and proper function within the fire alarm system.

  • Ayewo wiwo: Periodically inspect the unit for any signs of physical damage, loose connections, or environmental degradation.
  • Idanwo Iṣiṣẹ: Perform routine functional tests as required by local fire codes and the manufacturer's recommendations for the associated duct smoke detector. This typically involves using the test function of the RTS151KEY.
  • Ninu: If necessary, gently wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7. Laasigbotitusita

If the RTS151KEY or the connected duct smoke detector is not functioning as expected, consider the following common issues:

IsoroOwun to le FaOjutu
Duct detector does not test/reset from RTS151KEY.
  • Ti firanṣẹ ti ko tọ.
  • No power to the duct detector or RTS151KEY.
  • Faulty duct detector.
  • Key not fully turned or held.
  • Verify all wiring connections against the manual's diagram.
  • Check power supply to both devices.
  • Test the duct detector directly if possible.
  • Ensure the key is turned firmly to the TEST/RESET position and held briefly.
No indication on RTS151KEY during alarm/test.
  • LED indicator failure.
  • Wiring issue to indicator.
  • Confirm detector status at the main control panel.
  • Check wiring to the indicator terminals.

If problems persist, contact a qualified fire alarm technician or System Sensor technical support.

8. Awọn alaye ọja

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeRTS151KEY
Awọn iwọn (H x W x D)4 x 7 x 4 inches (isunmọ)
Iwọn Nkan3.84 iwon
Orisun agbaraDC NIKAN
UPC783863038075
OlupeseSensọ eto
IbamuDesigned for use with compatible System Sensor duct smoke detectors.

9. Atilẹyin ọja ati Support

For warranty information, please refer to the documentation provided with your purchase or contact System Sensor directly. System Sensor products are typically covered by a limited warranty against defects in materials and workmanship.

Oluranlowo lati tun nkan se

For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact System Sensor customer support. Contact information can usually be found on the manufacturer's official webaaye tabi ni apoti ọja.

Olùṣiṣẹ́ Sensọ Ètò Webojula: www.systemsensor.com

Awọn iwe aṣẹ ti o jọmọ - RTS151KEY

Ṣaajuview Sensọ Eto RTS151KEY(A) Awọn ilana Fifi sori ẹrọ ati itọju Ibudo Idanwo Latọna jijin
Àwọn ìlànà ìfisí àti ìtọ́jú fún Ibùdó Ìdánwò Remote Sensor RTS151KEY(A). Ìwé yìí pèsè àwọn ìlànà pàtó, àwọn àlàyé iṣẹ́, àwọn àwòrán wáyà, àti ìwífún ìdánilójú fún ọjà náà.
Ṣaajuview Ìtọ́sọ́nà Fífi sori ẹrọ àti Ìtọ́jú Ibùdó Ìdánwò Láàrín Ọ̀nà RTS151KEY(-A)
Àwọn ìlànà ìfisílẹ̀ àti ìtọ́jú tó kún rẹ́rẹ́ fún Ibùdó Ìdánwò Remote Sensor RTS151KEY(-A), tó bo àwọn ìlànà pàtó, iṣẹ́, àwòrán wáyà fún onírúurú ohun èlò ìwádìí (D4120, DNR, D2, OSID, DH400ACDC, BEAM1224), àti àlàyé nípa àtìlẹ́yìn.
Ṣaajuview RTS151KEY-Ibudo Idanwo Latọna jijin: Itọsọna Fifi sori ẹrọ ati Itọju
Àwọn ìlànà ìfisí àti ìtọ́jú tó péye fún Sẹ́nsì RTS151KEY-A Remote Test Station, pẹ̀lú àwọn ìlànà, iṣẹ́, àwòrán wáyà, àti ìwífún nípa àtìlẹ́yìn.
Ṣaajuview Sensọ Eto RTS151KEY(A) Awọn ilana Fifi sori ẹrọ ati itọju Ibudo Idanwo Latọna jijin
Ìtọ́sọ́nà pípé fún fífi sori ẹrọ àti ìtọ́jú Sẹ́nsì Ẹ̀rọ RTS151KEY(A) Ibùdó Ìdánwò Latọna jijin, pẹ̀lú àwọn ìlànà, iṣẹ́, àwòrán wáyà fún onírúurú àwọn ohun tí ń ṣe àwárí, àti ìwífún nípa àtìlẹ́yìn.
Ṣaajuview Awọn ilana fifi sori ẹrọ ati itọju ibudo idanwo latọna jijin RTS151KEYA
Ìtọ́sọ́nà ìfisílé àti ìtọ́jú fún Ẹ̀rọ Ìdánwò RTS151KEYA Remote Sensor, àlàyé àwọn ìlànà, iṣẹ́, àwòrán wáyà, àti ìwífún nípa ìdánilójú fún àwọn ètò ìwádìí iná.
Ṣaajuview Sensọ Sistẹ́mù RTS151KEY Ibudo Idanwo Latọna jijin: Itọsọna Fifi sori ẹrọ ati Itọju
Àwọn ìlànà ìfisí àti ìtọ́jú tó péye fún Sẹ́nsìlì Sensor RTS151KEY Remote Test Station, pẹ̀lú àwọn ìlànà, àwọn àlàyé iṣẹ́, àti àwọn àwòrán wáyà fún onírúurú àwọn ẹ̀rọ tí ń ṣe àyẹ̀wò èéfín àti páìpù.