Taco 006-B4

Taco 006-B4 Bronze Circulator Pump 3/4-Inch Sweat User Manual

Àwòṣe: 006-B4

1. Ifihan

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Taco 006-B4 Bronze Circulator Pump. The Taco 006-B4 is designed for circulating hot or chilled fresh water in various open or closed loop applications, including hydronic heating, domestic hot water recirculation, hydro-air heating/cooling, heat recovery units, water source heat pumps, drain-down open loop solar systems, and potable water applications. Please read this manual thoroughly before installation and operation.

2. Alaye Aabo

IKILO: Ikuna lati tẹle awọn ilana aabo wọnyi le ja si ipalara nla tabi ibajẹ ohun-ini.

3. Ọja Ipariview

The Taco 006-B4 is a compact and efficient bronze circulator pump designed for reliable performance in various water circulation systems. Its unique design features a replaceable cartridge containing all moving parts, simplifying service and extending product life.

Awọn ẹya pataki:

Taco 006-B4 Bronze Circulator Pump

Figure 1: Taco 006-B4 Bronze Circulator Pump. This image shows the compact design of the circulator pump with its bronze housing and electrical connection box.

4. Eto ati fifi sori

Proper installation is crucial for the optimal performance and longevity of your circulator pump. It is highly recommended that installation be performed by a qualified plumber or HVAC technician.

4.1 Pre-Fifi sọwedowo

4.2 Mounting and Piping

  1. Choose a location that allows for easy access for future servicing and provides adequate ventilation.
  2. Mount the pump securely in the piping system. The pump is designed for 3/4-inch sweat connections. Ensure proper soldering techniques are used to prevent leaks.
  3. Ensure the pump is installed with the motor shaft in a horizontal position to ensure proper lubrication and operation.
  4. Install isolation valves on both sides of the pump to facilitate future maintenance without draining the entire system.
  5. Fill the system with water and purge all air before operating the pump.

4.3 Electrical Awọn isopọ

5. Isẹ

5.1 Ibẹrẹ ibẹrẹ

  1. After installation and filling the system, ensure all air has been purged from the piping.
  2. Restore power to the pump. The pump should start operating quietly.
  3. Check for any leaks around the connections.
  4. Monitor the system for proper circulation and temperature distribution.

5.2 Isẹ deede

6. Itọju

The Taco 006-B4 circulator pump is designed for maintenance-free operation due to its self-lubricating properties and unique replaceable cartridge design.

6.1 Awọn sọwedowo baraku

6.2 Rirọpo katiriji

The unique replaceable cartridge contains all the moving parts of the circulator. If the pump requires service beyond simple checks, the cartridge can be replaced, effectively renewing the pump's internal components. Refer to the specific cartridge replacement instructions provided by Taco or consult a qualified technician.

  1. IKILO: Disconnect all power to the pump before attempting any service.
  2. Close the isolation valves on both sides of the pump.
  3. Drain the water from the pump section.
  4. Follow the manufacturer's instructions for removing and replacing the cartridge assembly.
  5. After replacement, reopen isolation valves, refill the system, purge air, and restore power.

7. Laasigbotitusita

This section provides solutions to common issues you might encounter with your Taco 006-B4 circulator pump. For problems not listed here, or if solutions do not resolve the issue, contact a qualified technician.

IsoroOwun to le FaOjutu
Pump ko ṣiṣẹNo power; tripped circuit breaker; faulty wiring; seized motor.Check power supply and circuit breaker. Verify wiring connections. If motor is seized, consider cartridge replacement or professional service.
Pump runs but no circulationAir in system; closed isolation valves; clogged impeller; incorrect rotation.Purge air from the system. Ensure isolation valves are fully open. Inspect impeller for obstructions (requires professional service). Verify correct motor rotation if applicable.
Ariwo dani tabi gbigbọnAir in system; cavitation; worn bearings (in cartridge); debris in pump.Purge air from the system. Ensure adequate water flow to prevent cavitation. If noise persists, consider cartridge replacement.
Pump is hot to the touchNormal operation; running dry; restricted flow; motor overload.Some heat is normal. Ensure pump is not running dry. Check for restricted flow in piping. If excessively hot, disconnect power and seek professional advice.
N jo ni awọn asopọImproperly sealed connections; damaged fittings.Tighten connections. If leaks persist, drain system and re-seal or replace fittings.

8. Awọn pato

Nọmba awoṣe006-B4
Iwon AsopọmọraÀwọ̀ 3/4 Inṣi
Ohun eloBronze (Housing), Cast Iron (Motor Casing)
Sisan Range0-10 GPM (Gallons Per Minute)
Ori Range0-9 Ẹsẹ
Minimum Fluid Temperature40°F (4°C)
O pọju ito otutu220°F (104°C)
O pọju Ṣiṣẹ Ipa125psi
Voltage115 Volts
Orisun agbaraAC/DC
Agbara Agbara Agbara0.025 HP (1/40 HP)
Iwọn Nkan4.41 poun (2 kg)
Ọja Mefa5 x 4 x 7 inches (12.7 x 10.2 x 17.8 cm)

9. Atilẹyin ọja ati Support

For detailed warranty information, please refer to the warranty card included with your product packaging or visit the official Taco website. If you require technical support, have questions about installation, or need assistance with troubleshooting, please contact Taco customer service or your authorized dealer.

Olupese: Taco, Inc.

Webojula: www.tacocomfort.com

Awọn iwe aṣẹ ti o jọmọ - 006-B4

Ṣaajuview Ìwé Ìtọ́ni fún Ayíká Ìṣiṣẹ́ Taco 0026e ECM
Ìwé ìtọ́ni fún Taco 0026e ECM High-Efficiency Circulator, tí ó ṣe àlàyé àwọn ẹ̀yà ara rẹ̀, àwọn ohun èlò rẹ̀, fífi sori ẹrọ, wáyà, ètò ìṣiṣẹ́, àti ìṣòro. Circulator iyara oníyípadà yìí ní ìpamọ́ agbára pàtàkì ó sì rọ́pò àwọn àwòṣe onípele kan àti onípele mẹ́ta àtijọ́.
Ṣaajuview Taco Hot-LinkPlus-e: Ètò Àtúnṣe Omi Gbóná Tó Gíga Jùlọ | Fífi sori ẹrọ & Àwọn Àlàyé Pàtàkì
Kọ́ nípa ètò Taco Hot-LinkPlus-e, ètò ìtúnṣe omi gbígbóná tó lágbára jùlọ ti ECM. Àwọn ohun èlò rẹ̀ ni omi gbígbóná lójúkan, ìpamọ́ omi, ìṣàkóso SmartPlug, àti fífi sori ẹrọ láìsí ìlà ìpadàbọ̀ pàtàkì. Ó ní àwọn ìlànà ìmọ̀-ẹ̀rọ àti ìtọ́sọ́nà ìfisílé.
Ṣaajuview Taco Domestic Hot Water Recirculation Systems: Application, Selection & Installation Guide
A comprehensive guide to Taco's Domestic Hot Water Recirculation (DHWR) systems, detailing their application, selection process, and installation. Learn how to achieve instant hot water, conserve water and energy, and choose the right Taco product for residential use.
Ṣaajuview Taco HLS-2 Gbona-Link System fun Domestic Hot Water Recirculation - Ilana dì
Iwe ilana fun Taco HLS-2 Hot-Link System, eto isọdọtun omi gbona inu ile ti a ṣe apẹrẹ lati pese omi gbigbona lẹsẹkẹsẹ ati fi omi pamọ. Pẹlu itọsọna fifi sori ẹrọ, awọn eto aago, laasigbotitusita, ati alaye atilẹyin ọja.
Ṣaajuview Taco Gbona-LinkPlus-e ECM Gbona Water Recirculation System Ilana Ilana
Itọsọna okeerẹ fun fifi sori ẹrọ ati ṣiṣẹ Taco Hot-LinkPlus-e ECM High-Efficiency Hot Water Recirculation System pẹlu iṣakoso SmartPlug, awọn ẹya alaye, awọn igbesẹ fifi sori ẹrọ, ati awọn imọran laasigbotitusita.
Ṣaajuview Taco 1911ecm ECM High-Efficiency Circulator Instruction Sheet
Instruction sheet for the Taco 1911ecm ECM High-Efficiency Circulator, covering installation, operation, controller functions, specifications, and troubleshooting. Learn about its features, safety guidelines, and maintenance.