APC SMT750I

APC Smart-UPS 750VA LCD 230V User Manual

Model: SMT750I

1. Ifihan

The APC Smart-UPS 750VA LCD 230V (Model SMT750I) is an Uninterruptible Power Supply (UPS) designed to provide reliable power protection for electronic equipment. It safeguards against power outages, voltage fluctuations, and surges, ensuring continuous operation and protecting sensitive devices. This manual provides essential information for the safe and efficient use of your UPS.

2. Alaye Aabo

Please read and understand these instructions carefully before installing or operating the UPS.

  • UPS yii jẹ ipinnu fun lilo inu ile nikan.
  • Ma ṣe ṣiṣẹ UPS yii ni isunmọ taara taara, ni olubasọrọ pẹlu awọn ito, tabi nibiti eruku pupọ tabi ọriniinitutu ba wa.
  • Connect the UPS power cable directly to a wall outlet. Do not use extension cords or surge protectors.
  • UPS ní àwọn bátìrì inú tí kò ṣeé lò. Tọ́ka sí àwọn òṣìṣẹ́ iṣẹ́ tó péye fún ìyípadà bátìrì.
  • Rí i dájú pé gbogbo ohun èlò tí a so pọ̀ mọ́ ilẹ̀ náà ní ìpìlẹ̀ tó yẹ.
  • In case of emergency, press the OFF button and disconnect the UPS from the AC power supply.

3. Package Awọn akoonu

Rii daju pe gbogbo awọn paati wa lori ṣiṣi silẹ:

  • APC Smart-UPS 750VA LCD 230V Unit
  • Okun Ibaraẹnisọrọ USB
  • Serial Communication USB
  • CD iwe
  • Ìtọ́sọ́nà Ààbò àti Ìtọ́sọ́nà Àtìlẹ́yìn
  • Power Cords (quantity may vary by region)

4. Eto

4.1 Unpacking ati ayewo

Carefully remove the UPS from its packaging. Inspect the unit for any shipping damage. If damage is found, notify the carrier and your dealer.

4.2 So Batiri pọ

The UPS is shipped with the battery disconnected for safety. To connect the battery:

  1. Locate the battery connector on the rear panel of the UPS.
  2. Remove the battery cover or pull out the battery tray slightly (refer to specific model instructions if different).
  3. Connect the battery terminals firmly. Ensure a secure connection.
  4. Replace the battery cover or push the battery tray back into place.

4.3 Connecting to Utility Power

Plug the UPS power cord into a grounded 230V AC outlet. The UPS will begin charging its battery. Allow the battery to charge for at least 24 hours before initial use to ensure maximum runtime capacity.

4.4 Ohun elo Nsopọ

Connect your electronic devices to the output receptacles on the rear of the UPS. Prioritize critical equipment that requires battery backup. The UPS provides both battery backup and surge protection for connected devices.

Ẹyìn view of APC Smart-UPS 750VA LCD 230V showing power outlets, USB port, UPS monitoring port, and battery connector.

Nọmba 1: Rear panel of the APC Smart-UPS 750VA LCD 230V, illustrating the various power outlets, communication ports (USB, UPS Monitoring), and the battery connector. Ensure all connections are secure.

5. Isẹ

5.1 Front Panel and LCD Display

The front panel features an LCD display and control buttons for monitoring and configuring the UPS. The LCD provides real-time information on UPS status, load, battery charge, and various settings.

Iwaju view of APC Smart-UPS 750VA LCD 230V with LCD screen and control buttons.

Nọmba 2: Iwaju view of the APC Smart-UPS 750VA LCD 230V, highlighting the intuitive LCD interface and control buttons for easy monitoring and configuration.

5.2 Awọn bọtini Iṣakoso

  • Titan/Apapa: Tẹ lati tan tabi pa UPS naa.
  • Menu/Escape: Navigates through menu options or exits a menu.
  • Awọn itọka oke/isalẹ: Scrolls through menu options or adjusts settings.
  • Wọle: Selects a menu option or confirms a setting.

5.3 Ibẹrẹ Ibẹrẹ

After connecting the battery and utility power, press the Power On button. The UPS will perform a self-test and then display its operational status. The LCD will show input voltage, iwọn didun ti o wujadetage, fifuye ogoruntage, and battery charge level.

5.4 Power Management Software

For advanced monitoring and control, connect the UPS to a computer using the provided USB cable. Install the APC PowerChute software (available on the documentation CD or APC website) to configure shutdown parameters, view event logs, and perform scheduled self-tests.

6. Itọju

6.1 Batiri Rirọpo

The UPS uses a 12V lead-acid battery. Batteries typically last 3-5 years depending on usage and environmental conditions. When the battery needs replacement, the UPS will indicate a battery fault. Contact APC customer support or a certified service technician for battery replacement to ensure safety and proper function.

6.2 Ninu

Periodically clean the exterior of the UPS with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris to prevent overheating.

6.3 Ibi ipamọ

If storing the UPS for an extended period, ensure the battery is fully charged. Disconnect the battery and store the unit in a cool, dry place. Recharge the battery every 3-6 months to prevent deep discharge and prolong battery life.

7. Laasigbotitusita

This section addresses common issues you might encounter with your UPS.

IsoroOwun to le FaOjutu
UPS ko ni tanBattery disconnected or discharged; No utility power.Ensure battery is connected; Check utility power connection; Allow battery to charge.
UPS beeps nigbagbogboLórí agbára bátìrì; Ipò àṣejù; Bátìrì tí kò pọ̀.Check utility power; Reduce connected load; Allow battery to charge.
Aami batiri ìmọlẹBattery fault or nearing end of life.Perform a self-test; If fault persists, consider battery replacement.
Ẹrọ ti a sopọmọ padanu agbaraUPS overload; Battery fully discharged.Reduce connected load; Allow battery to recharge.

For more complex issues or error codes displayed on the LCD, refer to the detailed troubleshooting section in the full product documentation or contact APC technical support.

8. Awọn pato

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣeSMT750I
Agbara750VA / 500W
Iṣagbewọle Voltage230V
O wujade Voltage230V
Igbohunsafẹfẹ50/60 Hz (auto-sensing)
Batiri IruLead Acid, 12V (1 battery required)
Awọn iwọn (H x W x D)5.43 x 6.34 x 14.29 inches (13.8 x 16.1 x 36.3 cm)
Iwọn29 poun (13.15 kg)
Àwọ̀Dudu
Awọn ibudo wiwoUSB, SmartSlot

9. Atilẹyin ọja ati Support

9.1 atilẹyin ọja Alaye

APC provides a standard warranty for this product. The warranty period typically covers defects in materials and workmanship under normal use. Specific warranty terms and conditions may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official APC webojula fun alaye alaye.

9.2 Imọ Support

If you encounter any issues or have questions regarding your APC Smart-UPS, please contact APC Technical Support. Have your product model number (SMT750I) and serial number ready when contacting support. Support contact information can typically be found on the APC webaaye tabi ninu iwe ọja rẹ.

Fun awọn orisun afikun, ṣabẹwo si APC official webojula.

Awọn iwe aṣẹ ti o jọmọ - SMT750I

Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò APC Back-UPS BX Series: Fífi sori ẹrọ, Iṣẹ́, àti Ìṣàtúnṣe
Ìwé ìtọ́ni tó péye fún APC Back-UPS BX Series (500VA sí 2200VA) láti ọwọ́ Schneider Electric, tó ní àwọn ìtọ́ni ààbò, àpèjúwe ọjà, àwọn ẹ̀yà iṣẹ́, fífi sori ẹ̀rọ, ṣíṣe àtúnṣe, iṣẹ́, àti ìwífún nípa àtìlẹ́yìn.
Ṣaajuview APC Easy Back UPS BX Series User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for APC Easy Back UPS BX Series (750VA, 950VA, 1200VA, 1600VA, 2200VA) covering safety information, product description, installation, operational features, specifications, status indicators, troubleshooting, service, and warranty.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Àtìlẹ́yìn APC BN600G
Ìwé ìtọ́ni fún APC Back-UPS BN600G Uninterruptible Power Supply (UPS), èyí tí ó ń pèsè ìwífún nípa ààbò, àwọn ìlànà pàtó, fífi sori ẹ̀rọ, iṣẹ́, ṣíṣe àtúnṣe, àti àwọn àlàyé ìdánilójú.
Ṣaajuview APC Back-UPS Pro 900 Installation and Operation Guide
This guide provides instructions for installing and operating the APC Back-UPS Pro 900, including setup, software installation, connection of equipment, operational features like power saving and display modes, troubleshooting, and specifications.
Ṣaajuview Ìwé Ìfisíṣẹ́ àti Ìṣiṣẹ́ APC Smart-UPS RT
This manual provides comprehensive instructions for the installation, operation, and maintenance of the APC Smart-UPS RT series, including models SURT1000 and SURT2000. It covers safety precautions, setup procedures, operational indicators, troubleshooting, and warranty information for these uninterruptible power supplies.
Ṣaajuview APC Back-UPS 1500 (BZ1500BI-BR) Installation and User Manual
This manual provides installation and usage instructions for the APC Back-UPS 1500 (BZ1500BI-BR), a interactive, microprocessor-controlled, on-line regulated UPS designed to ensure the operation of connected equipment during power failures or outages. It covers features, specifications, safety precautions, installation, troubleshooting, and warranty information.