A&D HT-300

A&D HT Series Compact Scale User Manual

Awoṣe: HT-300

Ọrọ Iṣaaju

This user manual provides comprehensive instructions for the safe and efficient operation, maintenance, and troubleshooting of your A&D HT Series Compact Scale, model HT-300. Please read this manual thoroughly before using the scale to ensure proper functionality and to prevent damage.

Alaye Aabo

Always observe the following safety precautions to ensure safe operation and to prevent damage to the scale or injury to the user:

Package Awọn akoonu

Jẹrisi pe gbogbo awọn ohun kan wa ninu package:

Ọja Pariview

A&D HT-300 Compact Scale with display showing 0.0g and control buttons

Figure 1: A&D HT-300 Compact Scale. This image shows the top view of the scale, highlighting the weighing pan, the LCD display, and the control buttons for power, hold, and re-zero/tare functions.

The A&D HT-300 Compact Scale is designed for precise weighing in various environments, including schools, laboratories, and for weighing small items like jewelry. It features a stainless steel pan, a backlit LCD display, and multiple units of measure.

Awọn ẹya pataki:

Ṣeto

  1. Ṣii silẹ: Fara yọkuro iwọn ati gbogbo awọn ẹya ẹrọ lati apoti.
  2. Ibi: Place the scale on a firm, level, and vibration-free surface. Ensure it is away from direct sunlight, drafts, and heat sources.
  3. Ibi ti ina elekitiriki ti nwa:
    • Iṣẹ Batiri: Open the battery compartment on the underside of the scale and insert the required batteries (check battery type and polarity).
    • AC Adaptor (Optional): If using the AC adaptor, plug it into the scale's power input jack and then into a suitable wall outlet.
  4. Agbara Ibẹrẹ Tan: Tẹ awọn TAN/PA button to turn on the scale. The display will show "88888" then "0.0g" (or the last used unit) when ready.

Awọn ilana Iṣiṣẹ

1. Agbara Tan / Paa

2. Ipilẹ Iwon

  1. Ensure the scale is on a stable surface and displays "0.0g".
  2. Gently place the item to be weighed on the center of the weighing pan.
  3. Wait for the reading to stabilize. The "STABLE" indicator will appear on the display.
  4. Read the weight displayed on the LCD.

3. Tare Function (Zeroing a Container)

The tare function allows you to subtract the weight of a container, so only the net weight of the contents is measured.

  1. Place the empty container on the weighing pan. The display will show its weight.
  2. Tẹ awọn →0/T← (RE-ZERO) button. The display will return to "0.0g" and the "NET" indicator will appear.
  3. Fi awọn ohun kan kun lati ṣe iwọn sinu apo eiyan naa. Ifihan naa yoo ṣe afihan iwuwo apapọ ti awọn nkan naa.
  4. To clear the tare, remove the container from the pan and press the →0/T← bọtini lẹẹkansi.

4. Changing Units of Measure

The HT-300 supports multiple units of measure (g, oz, lb-oz, ozt, N).

5. Duro Iṣẹ

The hold function allows you to temporarily freeze the displayed weight, even after the item is removed from the pan.

Itoju

Ninu:

Ibi ipamọ:

Laasigbotitusita

IsoroOwun to le FaOjutu
Iwọn ko ni tan-an.Low or dead batteries; AC adaptor not connected properly.Replace batteries; check AC adaptor connection.
Awọn kika ti ko pe.Scale not on a level surface; vibrations; air currents; overloaded.Place on stable, level surface; avoid drafts; do not exceed capacity.
Display shows "EEEE" or "O-Err".Aṣiṣe apọju.Remove item immediately. Do not exceed maximum capacity.
Display shows "Lo".Atọka batiri kekere.Rọpo awọn batiri.
Scale does not zero.Something on the pan; scale not stable.Remove all items from pan; ensure scale is stable.

If the problem persists after attempting the solutions above, please contact A&D customer support for assistance.

Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeHT-300
O pọju Agbara310 g
Agbara kika (d)0.1 g
Sipo ti Idiwong, oz, lb-oz, ozt, N
Ifihan IruLCD pẹlu Backlight
Iwọn Pan Ohun eloIrin ti ko njepata
Orisun agbaraBatteries (not specified in input, assuming common types like AA/AAA) or Optional AC Adaptor
Ọja Mefa7.68 x 5.35 x 1.85 inches
Iwọn Ọja1.21 iwon
Pataki Awọn ẹya ara ẹrọBacklit Display, Multiple Weighing Units, Auto Shut Off, Stable/Net/Zero indicators

Atilẹyin ọja ati Support

A&D Company, Ltd. provides a limited warranty for this product against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.

For technical support, service, or warranty inquiries, please contact A&D customer service through their official website or the contact information provided with your product packaging. When contacting support, please have your model number (HT-300) and purchase details ready.

For more information, visit the official A&D webojula: www.andweighing.com

Awọn iwe aṣẹ ti o jọmọ - HT-300

Ṣaajuview A&D HT Series Compact Scale Operating Instructions
Comprehensive operating instructions for A&D HT Series Compact Scales (HT-300, HT-3000, HT-500, HT-5000), covering setup, weighing procedures, specifications, and troubleshooting.
Ṣaajuview HT Series Compact Scale Operating Instructions
Comprehensive operating instructions for A&D HT series compact digital scales, covering setup, weighing procedures, specifications, and troubleshooting.
Ṣaajuview A&D HT Series Compact Scale Operating and Calibration Manual
Comprehensive operating instructions and calibration guide for A&D HT series compact scales, including models HT-300, HT-3000, HT-500, and HT-5000. Learn about specifications, battery installation, weighing procedures, automatic power-off, error messages, and advanced calibration methods using a weight or gravity compensation.
Ṣaajuview A&D FG-D-CWP Weighing Indicator Instruction Manual for Waterproof Digital Platform Scale
This instruction manual provides detailed information on the installation, operation, and maintenance of the A&D FG-D-CWP Waterproof Digital Platform Scale Weighing Indicator. Learn about its features, setup, sensitivity adjustment, and troubleshooting.
Ṣaajuview A&D FG-27 Bluetooth Communication Interface: User Guide
Instruction manual for the A&D FG-27 Bluetooth Communication Interface, detailing installation, connection, DIP switch settings, HID function, wireless communication, and compliance information for FG series scales.
Ṣaajuview A&D AD-4328 Weighing Indicator: Features and Specifications
Detailed information on the A&D AD-4328 weighing indicator, covering its features, specifications, applications, and connectivity options. Learn about its reliability, accuracy, and ease of use for various weighing tasks.