Fluke FLUKE-113

Fluke 113 True-RMS Utility Multimeter User Manual

Àwòṣe: FLUKE-113

1. Ifihan

The Fluke 113 True-RMS Utility Multimeter is a versatile digital multimeter designed for general-purpose electrical testing. It provides accurate measurements for various electrical properties, making it an essential tool for industrial and commercial applications.

This manual provides detailed instructions for the safe and effective use of your Fluke 113 multimeter. Please read it thoroughly before operation and retain it for future reference.

Fluke 113 True-RMS Utility Multimeter front view

olusin 1: Iwaju view of the Fluke 113 True-RMS Utility Multimeter, showing its display, rotary dial, and function buttons.

2. Eto

2.1 Unpacking ati ayewo

Upon receiving your Fluke 113 multimeter, carefully inspect the packaging for any signs of damage. Remove the multimeter and its accessories from the box. The package should contain the UTILITY MULTIMETER and a holster with built-in probe holders.

2.2 Fifi sori batiri

The Fluke 113 multimeter uses a 9V battery. A battery is typically installed from the factory. To access the battery compartment, refer to the maintenance section for instructions on opening the meter. Ensure the battery is correctly oriented according to the polarity markings.

2.3 Nsopọ Awọn itọsọna Igbeyewo

Insert the test leads into the appropriate input jacks on the multimeter. For most measurements, the black lead connects to the COM (common) jack and the red lead connects to the VΩHz jack.

Fluke 113 Multimeter held in hand

Figure 2: The Fluke 113 multimeter held in a gloved hand, demonstrating its ergonomic design and readiness for use.

3. Awọn ilana Iṣiṣẹ

The Fluke 113 offers both manual and auto-ranging capabilities for user flexibility. Always ensure the meter is set to the correct function and range before making any measurements.

3.1 Titan / Pa a

Rotate the central dial to the desired function to power on the meter. To power off, rotate the dial to the OFF position. The meter has a sleep mode to maximize battery life.

3.2 Iwọn AC / DC Voltage

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Rotate the dial to the V~ (Ìdìpọ̀ ACtage) tabi V- (DC Voltage) position. The meter supports auto-ranging.
  3. Touch the test probes to the circuit points where you want to measure voltage.
  4. Ka voltage value on the digital display. The 6000-count resolution, 3-1/2 digit digital display is backlit for readability in low-light conditions.
Fluke 113 Multimeter measuring electrical panel

Figure 3: The Fluke 113 multimeter being used to measure voltage within an electrical panel, highlighting its practical application.

3.3 Idiwọn Resistance

  1. Rii daju pe iyika naa ti ni agbara ṣaaju idiwọn resistance.
  2. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  3. Rotate the dial to the Ω Ipò (àtakò).
  4. Touch the test probes across the component or circuit path you wish to measure.
  5. Ka iye resistance lori ifihan.

3.4 Idiwọn Capacitance

The Fluke 113 measures capacitance up to 9,999 microfarads.

  1. Ensure the capacitor is fully discharged before measuring.
  2. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  3. Rotate the dial to the CAP (Ipo agbara).
  4. Fi ọwọ́ kan àwọn ìwádìí ìdánwò sí àwọn ebute capacitor.
  5. Ka iye kapasito lori ifihan.

3.5 Diode Check and Continuity

The meter has a diode check for testing general-purpose germanium, silicon, and power diodes. It also features a continuity beeper which provides audible detection of resistance by turning on at less than 25 ohms and off at 250 ohms. It is also able to simultaneously check for voltage ati itesiwaju.

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Rotate the dial to the Diode / Itesiwaju ipo.
  3. For diode check, place the probes across the diode. The display will show the forward voltage ju.
  4. For continuity, place the probes across the circuit path. An audible beep indicates continuity.

3.6 Max/Min and Hold Functions

  • O pọju/Iṣẹju: Tẹ awọn MINI MAX button to record signal fluctuations. The meter will display the maximum, minimum, and average readings.
  • Duro: Tẹ awọn DIMU button to freeze the current measurement on the display for easier reading.

4. Itọju

Proper maintenance ensures the longevity and accuracy of your Fluke 113 multimeter.

4.1 Ninu

Pa ọran naa pẹlu ipolowoamp cloth and mild detergent. Do not use abrasives or solvents. Keep the input jacks free of dirt and moisture.

4.2 Batiri Rirọpo

The meter uses a 9V battery with a battery life of approximately 300 hours without backlight. When the battery indicator appears on the display, replace the battery promptly.

  1. Turn the meter off and disconnect all test leads from the meter.
  2. Remove the screw from the battery compartment cover on the back of the meter.
  3. Gbe kuro ni ideri.
  4. Remove the old battery and replace it with a new 9V battery, observing polarity.
  5. Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.

4.3 Fiusi Rirọpo

If the meter fails to measure current, the fuse may need replacement. Refer to the full user guide for detailed instructions on fuse replacement, as this procedure requires opening the meter case.

5. Laasigbotitusita

This section addresses common issues you might encounter with your Fluke 113 multimeter.

IsoroOwun to le FaOjutu
Mita ko ni agbara lori.Batiri ti ku tabi ti ko tọ.Ṣayẹwo polarity batiri tabi ropo batiri 9V.
"OL" (Overload) ni a fihan.Measurement exceeds the selected range or meter's maximum capability.Select a higher range (if in manual ranging mode) or ensure the measurement is within the meter's specifications.
Awọn kika ti ko pe.Dirty test leads, low battery, or incorrect function/range selection.Clean test leads, replace battery, or verify function/range setting.
Continuity beeper not working.Circuit resistance is too high (above 250 ohms).Verify the circuit path is continuous and resistance is below 25 ohms for audible beep.

6. Awọn pato

  • Awọn iwọn: AC/DC voltage, resistance, capacitance
  • Awọn idanwo: Itesiwaju, Diode
  • Voltage Ibiti: Up to 600V (AC/DC)
  • Ibi atako: Up to 60 kiloohms
  • Iwọn Agbara: Up to 9,999 microfarads
  • Ifihan: 6000-count resolution, 3-1/2 digit digital display, backlit
  • RMS otitọ: Yes, for accurate readings on linear or nonlinear loads
  • Iwọn: Manual and Auto-ranging
  • Awọn iṣẹ: Max/Min recording, Data Hold
  • Iwọn Aabo: Category III to 600V, Category IV to 300V (IEC 61010 standards)
  • Orisun Agbara: Batiri 9V (fi sori ẹrọ)
  • Igbesi aye batiri: Approximately 300 hours (without backlight)
  • Awọn iwọn (H x W x D): 6.58 x 3.35 x 1.81 inches
  • Ìwúwo: 13 iwon. / 404 g
  • To wa: Meter, holster with built-in probe holders

7. Atilẹyin ọja & Atilẹyin

7.1 atilẹyin ọja Alaye

Fluke Corporation warrants this product to be free from defects in material and workmanship under normal use and service. The warranty period is specified in the product's official warranty statement, typically found in the full user manual or on the Fluke webojula. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

7.2 Onibara Support

For technical assistance, service, or repair, please contact Fluke Customer Service. You can find contact information and additional resources, including the full user guide, on the official Fluke webojula: www.fluke.com.

It is recommended to source genuine Fluke products from local authorized distributors to ensure product authenticity and valid warranty coverage.

Awọn iwe aṣẹ ti o jọmọ - FLUKE-113

Ṣaajuview Fluke 116 True-rms Multimeter Users Manual
User manual for the Fluke 116 True-rms Multimeter, covering its features, operation, measurements, maintenance, and specifications. Learn how to use this versatile digital multimeter for various electrical testing tasks.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Fluke 279 FC True-rms Thermal Multimeter: Àwọn Ẹ̀yà ara àti Iṣẹ́
Ìwé ìtọ́ni yìí fún àwọn olùlò ní àwọn ẹ̀kúnrẹ́rẹ́ àlàyé lórí Fluke 279 FC True-rms Thermal Multimeter. Kọ́ nípa agbára ìwọ̀n iná mànàmáná rẹ̀, àwọn ẹ̀yà ara àwòrán ooru tí a ṣepọ, àti ètò aláìlókun Fluke Connect™ fún ìṣàkóso dátà àti pínpín tí ó dára síi.
Ṣaajuview Fluke 179 Digital Multimeter: Itọju ati Itọsọna Iṣẹ aaye
Ṣawari Fluke 179 True-rms Digital Multimeter, ti a ṣe apẹrẹ fun itanna daradara ati itọju HVAC. Kọ ẹkọ nipa awọn ẹya rẹ, awọn pato, ati awọn ẹya ẹrọ ti a ṣeduro fun iṣẹ-isin aaye igbẹkẹle.
Ṣaajuview Fluke 110 True-RMS Multimeter: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn ẹ̀kúnrẹ́rẹ́ àlàyé àti àwọn ẹ̀yà ara ẹ̀rọ Fluke 110 compact True-RMS multimeter, tí a ṣe fún fífi iná mànàmáná sí ipò tó péye àti ìṣòro. Ó ní ìṣedéédé, ìdíwọ̀n ààbò, àti àwọn ohun èlò míì tó wà nínú rẹ̀.
Ṣaajuview Fluke 114, 115, 116, 117 Digital Multimeters: User Manual and Specifications
Detailed specifications, features, and user guide for Fluke 114, 115, 116, and 117 True-rms Digital Multimeters, covering safety, operation, maintenance, and technical data.
Ṣaajuview Fluke 116 True-rms Multimeter: Ìtọ́sọ́nà Ìtọ́kasí Kíákíá