Extech FL700

Extech FL700 Fluoride Meter User Manual

Awoṣe: FL700

1. Ifihan

The Extech FL700 Fluoride Meter is a precision instrument designed for the rapid and accurate measurement of fluoride ions in various aqueous samples, including drinking water. This device integrates a sensing electrode, measurement electronics, and a digital display into a single, portable unit, making it suitable for both field and laboratory applications.

The FL700 provides direct readings of total fluoride concentrations ranging from 9.99 ppm or mg/L down to 0.1 ppm. It features automatic temperature compensation to ensure measurement accuracy across varying environmental conditions.

2. Alaye Aabo

Please read and understand all safety precautions before operating the Extech FL700 Fluoride Meter. Failure to follow these instructions may result in injury or damage to the instrument.

  • Always handle the fluoride electrode with care. Avoid touching the sensing element directly.
  • When working with TISAB reagent tablets or any chemical solutions, wear appropriate personal protective equipment, including gloves and eye protection.
  • Do not immerse the entire meter in liquid. The meter is designed for electrode immersion only.
  • Store the meter and reagents in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Jeki kuro ni arọwọto awọn ọmọde.

3. Ọja Ipariview

The Extech FL700 Fluoride Meter is a compact and user-friendly device. Key components and features are outlined below:

Extech FL700 Fluoride Meter front view
Iwaju view of the Extech FL700 Fluoride Meter, showing the display and control buttons.
Hand holding Extech FL700 Fluoride Meter
The Extech FL700 Fluoride Meter held in hand, demonstrating its ergonomic design and clear display.
Close-up of Extech FL700 electrode tip
Sun mo tipetipe view of the fluoride electrode tip, which is integrated into the meter.
Extech FL700 Fluoride Meter in use with sample
The Extech FL700 Fluoride Meter being used to measure a liquid sample, showing the meter in its stand.
Extech FL700 Fluoride Meter and included accessories
All components included with the Extech FL700: the meter, sensor cap, TISAB reagent tablets, and neckstrap.

Awọn ẹya pataki:

  • Iṣatunṣe-ojuami meji: Ensures accurate measurements across the fluoride range.
  • Ibi ipamọ iranti: Stores up to 25 labeled readings for later review.
  • Field or lab testing: Designed for versatile use in various environments.
  • Fast response: Provides fluoride measurements in less than 1 minute.
  • Large dual LCD: Simultaneously displays ppm (or mg/L) and temperature with a bargraph.

4. Eto

4.1. Fifi sori batiri

The Extech FL700 requires four 3V button batteries (included). To install or replace batteries:

  1. Twist off the battery compartment cap located at the top of the meter.
  2. Insert the four 3V button batteries, ensuring correct polarity as indicated inside the compartment.
  3. Replace the battery compartment cap and twist to secure.

4.2. Igbaradi akọkọ

Before first use or after prolonged storage, prepare the electrode:

  1. Remove the sensor cap from the electrode tip.
  2. Rinse the electrode tip with distilled water.
  3. Condition the electrode by immersing it in a fluoride standard solution (e.g., 1 ppm or 10 ppm) for approximately 15-30 minutes.

5. Awọn ilana Iṣiṣẹ

5.1. Agbara lori / Paa

Tẹ awọn TAN/PA bọtini lati tan tabi pa mita naa.

5.2. Calibration (Two-Point)

Accurate calibration is crucial for reliable measurements. The FL700 supports two-point calibration.

  1. Prepare two fluoride standard solutions, typically one low concentration (e.g., 1 ppm) and one high concentration (e.g., 10 ppm). Ensure the solutions are at a stable temperature.
  2. Fi omi ṣan awọn elekiturodu pẹlu distilled omi ati ki o nù gbẹ.
  3. Immerse the electrode into the first standard solution.
  4. Tẹ mọlẹ KAL/ÌRECNT. button until 'CAL' appears on the display. The meter will automatically recognize the standard and calibrate. Wait for the reading to stabilize.
  5. Rinse the electrode again and immerse it into the second standard solution.
  6. Tẹ mọlẹ KAL/ÌRECNT. button again. The meter will complete the two-point calibration.
  7. The meter is now calibrated and ready for measurement.

5.3. Gbigbe Iwọn kan

To measure fluoride concentration in a sample:

  1. Rii daju pe mita naa ti ni iwọntunwọnsi.
  2. Fi omi ṣan awọn elekiturodu pẹlu distilled omi ati ki o nù gbẹ.
  3. Add TISAB (Total Ionic Strength Adjustment Buffer) reagent to your sample according to the reagent instructions. TISAB ensures that the fluoride ions are in a measurable form and minimizes interference.
  4. Immerse the electrode tip into the prepared sample solution. Ensure the tip is fully submerged.
  5. Allow the reading to stabilize on the display. The large dual LCD will show the fluoride concentration in ppm (or mg/L) and the temperature.
  6. Láti mú kíkà tó wà lọ́wọ́lọ́wọ́ dúró, tẹ Ipo/Dimu bọ́tìnì náà. Tẹ̀ lẹ́ẹ̀kan síi láti tú u sílẹ̀.

5.4. Recalling Stored Readings

The meter can store up to 25 labeled readings.

  • To recall stored readings, press the KAL/ÌRECNT. button briefly when not in calibration mode.
  • Lo awọn Ipo/Dimu button to scroll through the stored readings.

6. Itọju

6.1. Electrode Cleaning

Regular cleaning of the electrode ensures optimal performance.

  • After each use, rinse the electrode thoroughly with distilled water.
  • If the electrode becomes fouled or readings become erratic, clean it with a mild detergent solution or a specialized electrode cleaning solution. Rinse thoroughly with distilled water afterward.

6.2. Ibi ipamọ

Proper storage extends the life of the electrode and meter.

  • Always replace the sensor cap on the electrode tip when not in use. The cap should contain a small amount of electrode storage solution or a fluoride standard solution to keep the membrane hydrated. Do not store dry.
  • Tọju mita naa ni itura, ibi gbigbẹ.

6.3. Batiri Rirọpo

Replace batteries when the low battery indicator appears on the display or when the meter fails to power on. Refer to Section 4.1 for battery installation instructions.

7. Laasigbotitusita

IsoroOwun to le FaOjutu
Mita naa ko ṣiṣẹAwọn batiri ti o ku tabi ti ko tọṢayẹwo polarity batiri; ropo awọn batiri.
Àwọn ìwé kíkà tí kò péye tàbí tí kò dúró ṣinṣinDirty electrode; air bubbles on electrode; insufficient sample volume; expired or incorrect TISAB.Clean electrode; gently tap electrode to remove bubbles; ensure electrode is fully submerged; check TISAB.
Meter fails to calibrateIncorrect standard solutions; dirty electrode; electrode not conditioned; damaged electrode.Verify standard concentrations; clean and condition electrode; replace electrode if damaged.
Atọka batiri kekereAwọn batiri ti wa ni kekere.Replace all four 3V button batteries.

8. Awọn pato

SipesifikesonuẸ̀kúnrẹ́rẹ́
OlupeseExtech
Nọmba apakanFL700
Iwọn Nkan7.7 iwon
Ọja Mefa6.8 x 1.6 x 1.4 inches
Nọmba Awoṣe NkanFL700
Awọn batiriAwọn batiri irin Lithium 4 nilo (pẹlu)
AraFL700
Nkan Package opoiye1
Nọmba Awọn nkan1
Awọn irinše to waUnit, Instruction Guide
Batiri Cell TypeAlkaline
Akọkọ Wa ỌjọOṣu Keje 15, Ọdun 2008

9. atilẹyin ọja Information

The Extech FL700 Fluoride Meter comes with a full one-year warranty on parts and workmanship, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modification.

10. Atilẹyin

For technical support, service, or additional information, please visit the official Extech webojula tabi kan si wọn onibara iṣẹ Eka. O tun le ri alaye siwaju sii ati awọn ọja ni awọn Ile itaja Extech lori Amazon.

Awọn iwe aṣẹ ti o jọmọ - FL700

Ṣaajuview EXTECH 45170 4-in-1 Ọriniinitutu, Iwọn otutu, Sisan afẹfẹ, ati Itọsọna olumulo Mita Imọlẹ
Itọsọna olumulo fun EXTECH 45170, ọriniinitutu iwọn 4-in-1, iwọn otutu, ṣiṣan afẹfẹ, ati ina. Pẹlu iṣẹ ṣiṣe, awọn pato, ati alaye atilẹyin ọja.
Ṣaajuview Manuale Utente Misuratore di Radiazione UV-AB Extech UV505
Manuale utente completo fun il Misuratore ti Radiazione UV-AB Extech UV505. Fi istruzioni operative, pato tecniche, informazioni di sicurezza ati manutenzione.
Ṣaajuview Extech UV505 UV-AB Light Mita User Afowoyi
Itọsọna olumulo fun Extech UV505 UV-AB Light Mita. Iwe yii pese alaye alaye lori awọn ẹya ẹrọ, iṣẹ ṣiṣe, awọn pato, awọn iṣọra ailewu, ati itọju fun wiwọn UVA ati ina UVB.
Ṣaajuview Extech EX810 1000 Amp Klemmeter pade IR Thermometer Gebruikershandleiding
Gedetailleerde gebruikershandleiding voor de Extech EX810 1000 Amp klemmeter pade ingebouwde IR thermometer. Bevat ilana, veiligheidsrichtlijnen en technische specificaties voor nauwkeurige metingen van leta ti, stroroom, weerstand, capaciteit, frequentie en temperatuur.
Ṣaajuview Ìtọ́sọ́nà Olùlò Extech EX650 Series: 600A True RMS Digital Clamp Awọn mita
Itọsọna olumulo pipe fun Extech EX650 Series ti 600A True RMS digital clamp Àwọn mítà, tí ó bo àwọn àpẹẹrẹ EX650 àti EX655. Kọ́ nípa ìṣiṣẹ́, àwọn ẹ̀yà ara rẹ̀, ààbò rẹ̀, àti àwọn ìlànà pàtó fún ìpele AC/DC tó péye.tage, lọwọlọwọ, resistance, ati awọn wiwọn diẹ sii.
Ṣaajuview Ìtọ́sọ́nà Olùlò Extech DM100 Pocket Multimeter
Ìtọ́sọ́nà olùlò fún Extech DM100 4000 Count Autoranging Pocket Multimeter, tó bo ààbò, àwọn ìlànà pàtó, iṣẹ́, àwọn ẹ̀yà ara ẹ̀rọ, àti ìtọ́jú.