1. Ọja Ipariview
The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Awọn ẹya pataki:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

Olusin 1: Pariview of the Sicce Ultrazero Flat Sucking Pump.
2. Alaye Aabo
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
- Rii daju pe ipese agbara voltage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Pa awọn ọmọde ati awọn eniyan laigba aṣẹ kuro ni agbegbe iṣẹ.
- Rí i dájú pé a ti rì mọ́lẹ̀ pátápátá nígbà tí a bá ń ṣiṣẹ́ láti dènà kí ó má baà gbóná jù.
- Avoid running the pump dry for extended periods.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Eto ati fifi sori
Follow these steps to properly set up your Ultrazero pump:
- Yọ fifa soke: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
- Connect the Discharge Hose:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Gbe fifa soke: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Asopọ agbara: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Awọn ilana Iṣiṣẹ
The Ultrazero pump is designed for simple operation:
- Fi fifa soke: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Bẹrẹ Fifun: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Bojuto Ipele Omi: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Dáwọ́ fífọ́ omi dúró: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Itọju
Itọju deedee n ṣe idaniloju pe fifa rẹ yoo pẹ to ati pe yoo ṣiṣẹ daradara.
- Ninu: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Ṣayẹwo fun idoti: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Ayẹwo USB: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Ibi ipamọ: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Laasigbotitusita
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ. | Ko si ipese agbara. Okun agbara ti bajẹ. Motor overload protection activated. | Ṣayẹwo asopọ agbara ati iṣan. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n omi kò jáde. | Intake blocked. Discharge hose kinked or blocked. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Reduced pumping performance. | Partial blockage. Impeller worn. | Disconnect power, clean pump intake and impeller area. Kan si atilẹyin alabara fun iṣẹ. |
| Pump stops unexpectedly. | Overheating due to low water level or blockage. Aṣiṣe itanna. | Disconnect power, check water level and clear blockages. Allow to cool. Ti iṣoro ba wa, kan si atilẹyin alabara. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Imọ ni pato
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Sipesifikesonu | Iye |
|---|---|
| Brand | Sicce |
| Nọmba awoṣe | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000 l/h |
| O pọju. Ifijiṣẹ Giga | 3.1 m |
| Power Consumption (P1) | 80 W |
| Awọn ọna Voltage | 220-240V / 50Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Asopọ titẹ | 26.44 mm (3/4") AG |
| Hose Connection Diameter | 20 mm (3/4") |
| Max. Solids Size | 3 mm |
| Wíwọ Omi Ipele | Down to 2-3 mm |
| Awọn iwọn Ọja (Isunmọ.) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Iwọn Nkan | 2.6 kg (5.72 lbs) |
| Leefofo loju omi | Rara |
| Apọju Idaabobo | No (Internal thermal protection may exist, but no external reset) |
| Ipilẹṣẹ | Ṣe ni Italy |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Atilẹyin ọja ati Support
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Olupese: Ebara
Brand: Sicce
For further assistance, visit the official Sicce webaaye tabi kan si olupin agbegbe rẹ.