Fluke TL175

Ìwé Ìtọ́sọ́nà Olùlò fún Àwọn Olùdánwò Fluke TL175 TwistGuard

Awoṣe: TL175

1. Ifihan

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Alaye Aabo

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • Maṣe lo diẹ sii ju iwọn voltage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu voltagÀwọn ìwọ̀n wọ̀nyí lókè 30 V AC RMS, 42 V tente, tàbí 60 V DC.tages duro a mọnamọna ewu.

3. Awọn ẹya Ọja

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Olusin 1: Pariview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Eto ati fifi sori

  1. Ṣe ayẹwo Awọn Itọsọna: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Connect to Instrument: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Awọn ilana Iṣiṣẹ

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • Voltage Iwọn: Yan iwọn didun ti o yẹtage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Wiwọn lọwọlọwọ: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Àtakò/Ìtẹ̀síwájú: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Itọju

  • Ninu: Clean the test leads with a damp asọ ati ìwọnba detergent. Ma ṣe lo abrasive ose tabi epo.
  • Ayewo: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Ibi ipamọ: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. Laasigbotitusita

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Awọn kika ti ko pe:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Awọn pato

Ẹya ara ẹrọSipesifikesonu
Nọmba awoṣeTL175
Aabo RatingCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Lead Wire MaterialDouble Insulated Silicone
Awọn iwọn otutu ti nṣiṣẹ-20 si 55°C (-4 si 131°F)
Giga2000m (6,562')
IbamuEN61010-031
Ọja Mefa10 x 3 x 2 inches
Iwọn Nkan120 Giramu (4.23 iwon)

Kini o wa ninu apoti:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Atilẹyin ọja ati Support

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webojula.

Olupese: Ile-iṣẹ Fluke

Ọjọ Akọkọ Wa: Oṣu Kẹfa Ọjọ 1, Ọdun 2011

Awọn iwe aṣẹ ti o jọmọ - TL175

Ṣaajuview Fluke 179 Digital Multimeter: Itọju ati Itọsọna Iṣẹ aaye
Ṣawari Fluke 179 True-rms Digital Multimeter, ti a ṣe apẹrẹ fun itanna daradara ati itọju HVAC. Kọ ẹkọ nipa awọn ẹya rẹ, awọn pato, ati awọn ẹya ẹrọ ti a ṣeduro fun iṣẹ-isin aaye igbẹkẹle.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Fluke 15B+/17B+/18B+ Oní-nọ́mbà Mọ́mbà Oní-nọ́mbà
Ìwé ìtọ́ni tó péye fún Fluke 15B+, 17B+, àti 18B+ oní-nọ́ńbà, tó bo àwọn ẹ̀yà ara rẹ̀, iṣẹ́ rẹ̀, ààbò rẹ̀, ìtọ́jú rẹ̀, àti àwọn ìlànà pàtó rẹ̀. Ìwé yìí fúnni ní àwọn ìtọ́ni tó kún rẹ́rẹ́ fún lílo àwọn oní-nọ́ńbà fún onírúurú ìwọ̀n iná mànàmáná.
Ṣaajuview Fluke 106/107 Oníná Oníná Oníná Oníná Pọ́ńpútà: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn àlàyé ìmọ̀-ẹ̀rọ tó kún rẹ́rẹ́, àwọn àkíyèsí ọjà, àti ìwífún gbogbogbò fún àwọn multimeter oní-nọ́ńbà Fluke 106 àti 107 tí wọ́n ní palms. Kọ́ nípa àwọn ìlànà iná mànàmáná wọn, ìṣedéédé wọn, àwọn ẹ̀yà ara wọn, àti àwọn ẹ̀rọ tí ó wà nínú wọn.
Ṣaajuview Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
Ṣaajuview Ohun elo Adapter Fluke FEV100 fun Awọn ibudo Gbigba agbara Ọkọ ina: Data Imọ-ẹrọ ati Awọn pato
Ṣawari awọn alaye imọ-ẹrọ, awọn ẹya ara ẹrọ, ati awọn ilana idanwo fun Fluke FEV100 Adapter Kit, ti a ṣe lati ṣe idanwo lailewu ati daradara idanwo awọn ibudo gbigba agbara ọkọ ina (EVSEs). Pẹlu alaye aabo, ibaramu, ati awọn alaye pipaṣẹ.
Ṣaajuview Fluke 110 True-RMS Multimeter: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn ẹ̀kúnrẹ́rẹ́ àlàyé àti àwọn ẹ̀yà ara ẹ̀rọ Fluke 110 compact True-RMS multimeter, tí a ṣe fún fífi iná mànàmáná sí ipò tó péye àti ìṣòro. Ó ní ìṣedéédé, ìdíwọ̀n ààbò, àti àwọn ohun èlò míì tó wà nínú rẹ̀.