Fluke TP175

Fluke TP175 TwistGuard Test Probe Instruction Manual

Model: TP175 | Brand: Fluke

1. Ifihan

The Fluke TP175 TwistGuard Test Probes are designed for electrical testing, offering enhanced safety and precision. These probes feature an adjustable tip length, allowing users to reduce tip exposure for safety in higher category environments or extend it for precision in lower category applications. Compatible with various Fluke test leads, the TP175 probes are an essential accessory for professional electrical measurements.

2. Alaye Aabo

Always adhere to safety precautions when working with electrical equipment. Failure to do so may result in injury or damage to equipment.

  • Ṣayẹwo Ṣaaju Lilo: Always inspect test leads and probes for damage (e.g., cracks, frayed insulation) before each use. Do not use damaged equipment.
  • CAT Ratings: The TP175 probes are rated CAT II 1000V, CAT III 1000V, and CAT IV 600V. Ensure the probes' rating matches or exceeds the environment and voltage ni won.
  • Adjust Tip Shroud: Use the TwistGuard feature to expose only the necessary amount of tip. For higher CAT environments, minimize tip exposure to reduce the risk of arc flash.
  • O pọju-wonsi: Maṣe kọja iwọn ti o pọjutagìwọ̀n e (1000V) tàbí ìwọ̀n lọ́wọ́lọ́wọ́ (10A).
  • Ipele Idoti: Rated for Pollution Degree 2 environments. Avoid use in excessively dirty or wet conditions.
  • Atokọ UL: These probes are UL Listed, indicating compliance with safety standards.

3. Ọja Ipariview

The Fluke TP175 TwistGuard Test Probes are designed for versatility and safety in electrical measurements. Key features include:

  • Adjustable Tip Length: Patented TwistGuard extendable tip shroud allows adjustment of tip exposure from 2mm to 19mm.
  • Awọn idiyele Aabo: CAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum.
  • Ibamu: Designed to be compatible with Fluke TL22x series, TL238, and TL27 test leads.
  • Ikole ti o tọ: Built for professional use in various environmental conditions.
Fluke TP175 TwistGuard Test Probes, showing one probe with extended tip and one with retracted tip.

Figure 1: Fluke TP175 TwistGuard Test Probes. One probe shows the tip extended for precision, and the other shows the tip retracted for safety.

4. Eto

To prepare your Fluke TP175 TwistGuard Test Probes for use:

  1. Connect to Test Leads: Insert the banana plug end of the TP175 probes firmly into the corresponding jacks on your compatible Fluke test leads (e.g., TL22x series, TL238, TL27). Ensure a secure connection.
  2. Adjust Tip Shroud: The TwistGuard mechanism allows you to adjust the exposed tip length. Rotate the red or black shroud on the probe to extend or retract the metal tip.
    • For CAT III/IV environments, retract the shroud to expose only 2mm of the tip for maximum safety.
    • For CAT II environments or when greater reach is required, extend the shroud to expose up to 19mm of the tip.
Fluke TP175 Test Probes connected to red and black test leads.

Figure 2: Fluke TP175 Test Probes connected to standard red and black test leads, ready for use.

5. Awọn ilana Iṣiṣẹ

Once the TP175 probes are securely connected to your multimeter's test leads and the tip shroud is adjusted for the measurement environment, proceed with your electrical tests.

  1. Select Measurement Function: On your multimeter, select the appropriate function (e.g., AC Voltage, DC Voltage, Resistance, Continuity, Current).
  2. Apply Probes: Carefully touch the probe tips to the test points of the circuit or component you are measuring. Ensure good contact.
    • Fun voltage measurements, place probes across the points where voltage ni ki won won.
    • For current measurements, the probes are typically used in series with the circuit, or a clamp meter function may be used if available on your primary device.
    • For continuity or resistance, ensure the circuit is de-energized before applying probes.
  3. Ka Iwọn: Observe the reading on your multimeter display.
  4. Remove Probes: Always remove the probes from the circuit after completing the measurement.
A gloved hand using a Fluke TP175 Test Probe to measure an electrical connection.

Figure 3: Proper use of the Fluke TP175 Test Probe for making a measurement on an electrical connection, demonstrating safe handling with gloves.

6. Itọju

Proper maintenance ensures the longevity and accuracy of your Fluke TP175 Test Probes.

  • Ninu: Clean the probes with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure probes are completely dry before storage or next use.
  • Ayewo: Regularly inspect the probes for any signs of wear, cuts, cracks, or damage to the insulation or tip. Replace immediately if any damage is found.
  • Ibi ipamọ: Store the probes in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid kinking or sharply bending the leads.

7. Laasigbotitusita

If you encounter issues with your Fluke TP175 Test Probes, consider the following:

  • No Reading/Intermittent Reading: Check for loose connections between the probes and the test leads, or between the test leads and the multimeter. Ensure the probe tips are making good contact with the test points.
  • Awọn kika ti ko pe: Verify that the multimeter is set to the correct measurement function and range. Ensure the probes are not damaged and are clean.
  • Bibajẹ ti ara: If the insulation is cracked, cut, or the tip is bent or broken, the probes must be replaced immediately to ensure safety and proper function.

8. Awọn pato

Ẹya ara ẹrọSipesifikesonu
AwoṣeTP175
Voltage Rating1000V
Ti isiyi RatingIye ti o ga julọ ti 10A
Awọn idiyele CATCAT II 1000V, CAT III 1000V, CAT IV 600V
Italologo Opin2mm
Idoti ìyí2
Ayika-wonsi-20 to 55 °C (-4 to 131 °F), Altitude: 2000m (6562 ft)
Awọn iwọn10 x 7.5 x 2.5 cm
Iwọn59 g
IjẹrisiUL Listed, Conforms to EN61010-031

9. Atilẹyin ọja ati Support

The Fluke TP175 TwistGuard Test Probes come with a 1-odun atilẹyin ọja.

For warranty claims, technical support, or additional product information, please visit the official Fluke website or contact your authorized Fluke distributor. Ensure you retain your proof of purchase for warranty validation.

Awọn iwe aṣẹ ti o jọmọ - TP175

Ṣaajuview Fluke 106/107 Oníná Oníná Oníná Oníná Pọ́ńpútà: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn àlàyé ìmọ̀-ẹ̀rọ tó kún rẹ́rẹ́, àwọn àkíyèsí ọjà, àti ìwífún gbogbogbò fún àwọn multimeter oní-nọ́ńbà Fluke 106 àti 107 tí wọ́n ní palms. Kọ́ nípa àwọn ìlànà iná mànàmáná wọn, ìṣedéédé wọn, àwọn ẹ̀yà ara wọn, àti àwọn ẹ̀rọ tí ó wà nínú wọn.
Ṣaajuview Ìtọ́sọ́nà Ìtọ́kasí Kíákíá fún Fluke 88 V Automotive Multimeter
Ìtọ́sọ́nà ìtọ́kasí kíákíá fún Fluke 88 V Automotive Multimeter, tí ó ṣàlàyé àwọn iṣẹ́ rẹ̀ àti lílò rẹ̀ fún ìdánwò iná mànàmáná ọkọ̀ ayọ́kẹ́lẹ́, pẹ̀lú vol.tage, lọwọlọwọ, resistance, iwọn otutu, ati awọn idanwo ọkọ ayọkẹlẹ pataki.
Ṣaajuview Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
Ṣaajuview Ohun elo Adapter Fluke FEV100 fun Awọn ibudo Gbigba agbara Ọkọ ina: Data Imọ-ẹrọ ati Awọn pato
Ṣawari awọn alaye imọ-ẹrọ, awọn ẹya ara ẹrọ, ati awọn ilana idanwo fun Fluke FEV100 Adapter Kit, ti a ṣe lati ṣe idanwo lailewu ati daradara idanwo awọn ibudo gbigba agbara ọkọ ina (EVSEs). Pẹlu alaye aabo, ibaramu, ati awọn alaye pipaṣẹ.
Ṣaajuview Fluke 110 True-RMS Multimeter: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn ẹ̀kúnrẹ́rẹ́ àlàyé àti àwọn ẹ̀yà ara ẹ̀rọ Fluke 110 compact True-RMS multimeter, tí a ṣe fún fífi iná mànàmáná sí ipò tó péye àti ìṣòro. Ó ní ìṣedéédé, ìdíwọ̀n ààbò, àti àwọn ohun èlò míì tó wà nínú rẹ̀.
Ṣaajuview Fluke 116 True-rms Multimeter Users Manual
User manual for the Fluke 116 True-rms Multimeter, covering its features, operation, measurements, maintenance, and specifications. Learn how to use this versatile digital multimeter for various electrical testing tasks.