Hanna Instruments HI98331

Ìtọ́sọ́nà Olùlò Hanna Instruments Groline Taara Olùdánwò Ìhùwàsí Ilẹ̀ HI98331

Awoṣe: HI98331

1. Ifihan

This manual provides essential instructions for the proper use and maintenance of your Hanna Instruments Groline Soil Test Direct Soil Conductivity Tester, model HI98331. Please read this manual thoroughly before operating the device to ensure accurate measurements and prolong the life of your instrument.

Hanna Instruments Groline Soil Test Direct Soil Conductivity Tester HI98331

Figure 1: Hanna Instruments Groline Soil Test Direct Soil Conductivity Tester HI98331. This image shows the complete device, featuring a digital display and a long, slender probe for direct soil insertion.

2. Alaye Aabo

Always handle the instrument with care. Do not immerse the meter body in water. Keep the battery compartment dry. Store the device in a cool, dry place when not in use.

3. Ọja irinše

The HI98331 Groline Soil Test Direct Soil Conductivity Tester includes:

Battery compartment of HI98331 tester

Figure 2: Battery compartment. This image shows the rear of the meter with the battery cover removed, revealing the CR2 battery slot.

4. Eto ati Batiri sori

The HI98331 meter comes with batteries pre-installed. If replacement is necessary:

  1. Wa ideri ibi ipamọ batiri naa ni ẹhin mita naa.
  2. Twist the cover counter-clockwise to remove it.
  3. Remove the old CR2 battery and insert a new one, observing polarity.
  4. Rọpo ideri kompaktimeti batiri ki o si yi lọna aago lati ni aabo.

Ensure the battery compartment is sealed tightly to prevent moisture ingress.

5. Awọn ilana Iṣiṣẹ

Follow these steps for accurate bulk EC measurement using your HI98331 Direct Soil EC Meter:

  1. Prepare the Testing Location: Select the specific area in the soil where you wish to take a measurement.
  2. Mọ Iwadii naa: Rinse the testing probe thoroughly with deionized water. Gently wipe it dry with a clean, soft cloth.
  3. Moisten the Soil: Ensure the soil in the testing area is adequately moist. Dry soil will not yield accurate readings.
  4. Create an Insertion Hole: Use a ruler or an auger to create a pilot hole in the soil. This helps maintain consistent testing depth and prevents damage to the probe.
  5. Insert the Tester: Carefully insert the HI98331 soil conductivity tester directly into the prepared hole in the soil. Ensure good contact between the probe and the soil.
  6. Ṣe Iwọnwọn: Wait for the reading on the digital display to stabilize. Record the displayed EC value.
HI98331 tester in use, showing display

Figure 3: Meter in operation. This image depicts the HI98331 meter with its probe inserted into soil, displaying a reading on its screen.

6. Iṣatunṣe

For optimal accuracy, regular calibration of your HI98331 is recommended. Refer to the specific calibration instructions provided in the full product manual or on the manufacturer's website. Typically, calibration involves using standard EC solutions.

7. Itọju ati Ipamọ

8. Laasigbotitusita

IsoroOwun to le FaOjutu
No display/Meter does not turn onAwọn batiri ti o ku tabi fifi sori ẹrọ batiri ti ko tọ.Ṣayẹwo polarity batiri; ropo awọn batiri.
Awọn kika ti ko peDirty probe, dry soil, or meter out of calibration.Clean probe, moisten soil, perform calibration.
Awọn kika kika alaibamuPoor contact with soil, air bubbles, or damaged probe.Re-insert probe firmly, ensure soil is moist, inspect probe for damage.

9. Awọn pato

ParamitaẸ̀kúnrẹ́rẹ́
AwoṣeHI98331
Iwọn Iwọn(Information not provided in source, typical for EC meters)
Ipinnu(Information not provided in source)
Yiye(Information not provided in source)
Biinu iwọn otutuBiinu Igba otutu Laifọwọyi (ATC)
Ibi ti ina elekitiriki ti nwa1 x CR2 batiri
Awọn iwọn9.41 x 2.64 x 1.26 inches
Iwọn5.61 iwon

10. Atilẹyin ọja ati Support

For warranty information and technical support, please refer to the official Hanna Instruments webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ bi ẹri rira.

Olupese: Hanna Instruments

Webojula: www.hannainst.com

Awọn iwe aṣẹ ti o jọmọ - HI98331

Ṣaajuview Afowoyi de Instrucciones Hanna HI98330 Tester de Nutrientes GroLine® CE/TDS
Afowoyi de instrucciones detallado para el Tester de Nutrientes Hanna HI98330 GroLine® CE/TDS. Cubre especificaciones, operación, mantenimiento, limpieza y garantía para aplicaciones hidropónicas y agrícolas.
Ṣaajuview Manual de Instrucciones Hanna edge CE HI2003: Guía Completa
Descubra cómo utilizar el medidor de conductividad Hanna edge CE HI2003 con este manual de instrucciones detallado. Incluye configuración, calibración, operación y especificaciones.
Ṣaajuview HANNA HI 8424 NEW Portable pH/mV/°C Ilana Ilana Mita
Ilana itọnisọna pipe fun HANNA HI 8424NEW to šee gbe pH/mV/°C mita. Kọ ẹkọ nipa awọn ẹya rẹ, awọn pato, itọsọna iṣiṣẹ, awọn ilana isọdiwọn, itọju, ati laasigbotitusita. Pẹlu awọn alaye lori isọdiwọn aifọwọyi ati gbigba agbara inductive.
Ṣaajuview Hanna Instruments HI98197 Mabomire Portable EC Mita fun Ultrapure Omi
Hanna Instruments HI98197 jẹ ọjọgbọn kan, mabomire, mita EC (conductivity) šee gbe ti a ṣe apẹrẹ fun awọn ohun elo omi ultrapure. O ṣe afihan ifihan ti o ga julọ, isọdiwọn aaye pupọ, isanpada iwọn otutu laifọwọyi, ati awọn agbara gedu data. Mita naa jẹ iwọn IP67 ati pẹlu iwadii Pilatnomu oruka mẹrin kan fun awọn wiwọn deede kọja sakani jakejado.
Ṣaajuview HANNA HI981954: Mita omi pupọ fun pH, ORP, EC, TDS ati diẹ sii
Discover the HANNA HI981954, a rugged, waterproof multiparameter meter designed for accurate field measurements of pH, ORP, EC, TDS, Resistivity, Salinity, Seawater, and Temperature. Ideal for various water quality testing applications.
Ṣaajuview Hanna HI9810382 HALO2 Wireless pH Tester for Bread & Dough Instruction Manual
Comprehensive instruction manual for the Hanna HI9810382 HALO2 wireless pH tester, designed for bread and dough. Covers specifications, setup, calibration, maintenance, error messages, accessories, and certifications.