1. Ifihan ati Ọja Loriview
This manual provides essential information for the safe and effective use of the GE SELA36AT0150 Bolt-On Mount Type SEL Molded Case Circuit Breaker. This current-limiting circuit breaker is designed for industrial and commercial applications, providing protection against overcurrents and short circuits.
Awọn ẹya pataki pẹlu:
- Current Limiting Circuit Breaker: Designed to limit the magnitude and duration of short-circuit currents.
- 150 Amps Max | 150 A Rating Plug: Configured for a maximum current of 150 Amps with a corresponding rating plug.
- 3 Pole, 480/600 VAC: Suitable for three-phase alternating current systems up to 600 Volts.
- Spectra RMS Series: Part of the GE Spectra RMS line, known for advanced protection features.
- Bọ́tì-Lórí: Designed for secure bolt-on installation.

olusin 1: Iwaju view of the GE SELA36AT0150 Circuit Breaker, showing the ON/OFF switch and product labels.
2. Alaye Aabo
IKILO: Installation, maintenance, and troubleshooting of electrical equipment should only be performed by qualified and licensed electricians. Failure to follow these instructions can result in serious injury, death, or property damage.
- Always disconnect power before working on electrical circuits or equipment.
- Lo ohun elo aabo ti ara ẹni ti o yẹ (PPE), pẹlu awọn ibọwọ idabo ati aabo oju.
- Daju pe gbogbo awọn asopọ wa ni aabo ati yiyi daradara ni ibamu si awọn pato.
- Ensure the circuit breaker's ratings match the system requirements.
3. Eto ati fifi sori
The GE SELA36AT0150 is a bolt-on mount circuit breaker. Proper installation is crucial for safe and reliable operation.
3.1 Pre-Fifi sọwedowo
- Confirm the circuit breaker's voltage, current, and interrupting ratings are compatible with the electrical system.
- Ṣe àyẹ̀wò ẹ̀rọ ìdènà ìṣiṣẹ́ náà fún ìbàjẹ́ ara. Má ṣe fi àwọn ẹ̀rọ tí ó bàjẹ́ síbẹ̀.
- Rii daju pe ilẹ iṣagbesori jẹ mimọ, gbẹ, ati ohun igbekalẹ.
3.2 iṣagbesori Awọn ilana
- De-energize the electrical panel or system where the breaker will be installed. Verify zero voltage pẹlu multimeter kan.
- Position the circuit breaker in the designated slot or mounting location.
- Secure the breaker using appropriate bolts and hardware for bolt-on mounting. Ensure it is firmly seated.
- Connect the load and line conductors to the appropriate terminals. The breaker includes a set of bottom lugs.
- Refer to the product label for specific wire ranges and torque specifications:
- Wire Range: #12 - 3/0 CU, #12 - 3/0 AL
- Torque: #12-#10: 35 lb-in, #8-#3: 100 lb-in, #2-3/0: 150 lb-in
- Double-check all connections for tightness and proper insulation.

Figure 2: Close-up of the circuit breaker's main label, detailing Cat No., Amp rating, Voltage, Pole configuration, Rating Plug Type, Lug Data, Wire Range, and Torque specifications.

Figure 3: Close-up of the circuit breaker's interrupting rating label, showing RMS Symmetrical Amps at various voltages (240V, 480V, 600V) and international standards.

olusin 4: Ẹyìn view of the GE SELA36AT0150 Circuit Breaker, showing the bolt-on mounting points and terminal connections.
4. Awọn ilana Iṣiṣẹ
The GE SELA36AT0150 circuit breaker is designed for simple operation, primarily acting as an ON/OFF switch and an automatic protective device.
4.1 Titan / Pa a
- Láti yí àyíká náà padà ON, firmly push the handle to the "ON" position.
- Láti yí àyíká náà padà PAA, firmly push the handle to the "OFF" position.
4.2 Ìrìnnà àti Àtúntò
If an overcurrent or short circuit condition occurs, the breaker will automatically "trip" to the center position (between ON and OFF) to protect the circuit. To reset a tripped breaker:
- First, move the handle completely to the "OFF" position. This resets the internal mechanism.
- Investigate and resolve the cause of the trip (e.g., overloaded circuit, short circuit).
- Once the issue is resolved, firmly push the handle to the "ON" position to restore power.
- If the breaker immediately trips again, do not attempt to reset it repeatedly. Consult a qualified electrician.
5. Itọju
Awọn fifọ Circuit ni gbogbogbo nilo itọju iwonba. Sibẹsibẹ, ayewo igbakọọkan ni a gbaniyanju lati rii daju pe iṣiṣẹ ailewu tẹsiwaju.
- Ayewo wiwo: Lọdọọdun ṣayẹwo awọn fifọ fun awọn ami ti ara bibajẹ, discoloration, tabi alaimuṣinṣin awọn isopọ.
- Ninu: Keep the area around the breaker clean and free of dust and debris. Use a dry, non-conductive cloth for cleaning. Do not use liquids.
- Awọn ayẹwo Asopọmọra: Periodically (e.g., every 3-5 years, or as per local codes) have a qualified electrician check the tightness of terminal connections.
- Idanwo: For critical applications, periodic testing of the breaker's trip mechanism by a qualified professional may be required.
Akiyesi: Do not attempt to open or repair the circuit breaker. There are no user-serviceable parts inside.
6. Laasigbotitusita
Abala yii n ṣapejuwe awọn ọran ti o wọpọ ti o le ba pade pẹlu ẹrọ fifọ ayika rẹ.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Awọn irin ajo fifọ nigbagbogbo. | Ayika ti a ti kojọpọ, Circuit kukuru, ẹbi ilẹ, tabi ohun elo ti ko tọ. | Dín ẹrù tó wà lórí ẹ̀rọ náà kù. Yọ àwọn ẹ̀rọ ìsopọ̀ mọ́ra kúrò. Ṣe àyẹ̀wò wáyà fún ìbàjẹ́. Tí ìṣòro náà bá ń bá a lọ, kan sí onímọ̀ ẹ̀rọ iná mànàmáná tó mọ̀ nípa rẹ̀. |
| Fifọ ko ni tunto. | Persistent fault (short circuit/overload) or internal breaker damage. | Ensure the handle is pushed fully to "OFF" before attempting to reset. If it still won't reset, do not force it. Call a qualified electrician. |
| Ko si agbara si iyika, ṣugbọn fifọ ni ON. | Loose connection, wiring issue, or internal breaker failure. | This indicates a serious issue. Immediately turn off the breaker and consult a qualified electrician. Do not attempt to diagnose or fix yourself. |
For any issues not covered here, or if troubleshooting steps do not resolve the problem, always contact a qualified and licensed electrician.
7. Awọn pato
Detailed technical specifications for the GE SELA36AT0150 Circuit Breaker:
| Iwa | Iye |
|---|---|
| Nọmba awoṣe | SELA36AT0150 |
| Brand | Gbogbogbo Electric |
| Ti isiyi Rating | 150 Amps |
| Voltage Rating | 480/600 VAC |
| Nọmba ti polu | 3 |
| Iru Circuit Fifọ | Standard, Current Limiting, Molded Case |
| Iṣagbesori Iru | Bolt-Lori Oke |
| Interrupting Rating @ 240 VAC | 100,000 Amps |
| Interrupting Rating @ 480 VAC | 65,000 Amps |
| Interrupting Rating @ 600 VAC | 25,000 Amps |
| Rating Plug Type | SRPE150A |
| Rating Plug Inst. Adjustable Range | 450-1991 A (Lo to Hi) |
| Awọn iwọn Ọja (D x W x H) | 4" x 4" x 6.5" (isunmọ) |
| Iwọn | 4.8 lbs (isunmọ) |
| Ọjọ Akọkọ Wa | Oṣu Kẹwa Ọjọ 11, Ọdun 2012 |
8. Atilẹyin ọja ati Support
For specific warranty information regarding your GE SELA36AT0150 Circuit Breaker, please refer to the documentation provided at the time of purchase or contact General Electric directly. As a general guideline, electrical components typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, service, or to inquire about replacement parts, please contact General Electric customer service or visit their official webojula. O tun le ṣàbẹwò awọn GE Store on Amazon for more information on GE products.
Always ensure that any work on electrical systems is performed by qualified and licensed professionals.
9. Awọn fidio ọja osise
No official product videos from the seller were found for this specific model in the provided data. For general product information or installation guides, please check the manufacturer's official webojula tabi awọn olupin ti a fun ni aṣẹ.