ASHCROFT 251009SW02BXLLVAC

Ìwé Ìtọ́sọ́nà fún Agbára Ẹ̀rọ Agbára ASHCROFT

Model: 251009SW02BXLLVAC

1. Ifihan

This manual provides essential information for the proper installation, operation, and maintenance of your ASHCROFT Vacuum Gauge. This test gauge is designed for precise vacuum measurement, featuring a durable construction suitable for industrial applications.

The gauge has a 2-1/2 inch dial, measures vacuum from 30 inches of Mercury (Hg) to 0, and features a 1/4 inch NPT connection located at the lower back. It is constructed with a 304 stainless steel case, 316 stainless steel socket and tube, and a polycarbonate lens. The gauge is filled with glycerin for dampening and enhanced performance.

ASHCROFT Vacuum Gauge

Nọmba 1: ASHCROFT Vacuum Gauge. This image displays the front view of the vacuum gauge, highlighting its stainless steel casing, white dial with black markings, and the ASHCROFT DURALIFE branding. The gauge face indicates measurements in psi and notes "Welded AISI 316 tube & socket U.S.A."

2. Alaye Aabo

Always observe standard safety precautions when handling and installing pressure and vacuum gauges. Failure to do so may result in injury or damage to equipment.

  • Ensure the system is depressurized before installing or removing the gauge.
  • Do not exceed the specified operating range of 30" Hg Vac to 0.
  • Verify compatibility of the gauge's wetted parts (316 Stainless Steel) with the process media.
  • Protect the gauge from extreme temperatures outside the -40°F to 150°F operating range.
  • Handle with care to avoid dropping or impacting the gauge, which can affect accuracy.

3. Eto ati fifi sori

Proper installation is crucial for accurate readings and long service life.

  1. Igbaradi: Ensure the connection port on your system is clean and free of debris.
  2. Asopọmọra: The gauge features a 1/4 inch NPT (National Pipe Taper) connection. Apply appropriate thread sealant (e.g., PTFE tape) to the male threads of the gauge connection.
  3. Iṣagbesori: Carefully thread the gauge into the system's female NPT port. Tighten using a wrench on the wrench flats of the gauge connection. Do not overtighten or apply torque to the gauge case.
  4. Iṣalaye: The connection location is lower back, allowing for direct mounting or panel mounting with appropriate accessories (not included). Ensure the dial is easily visible for reading.

4. Awọn ilana Iṣiṣẹ

The ASHCROFT Vacuum Gauge provides accurate vacuum measurements within its specified range.

  • Kíkà Ìwé Gíga: The dial is marked from 30" Hg Vac (full vacuum) to 0 (atmospheric pressure). The smallest graduation is 0.5" Hg, allowing for precise readings.
  • Yiye: This gauge has an accuracy of +/-1.0% of span, ensuring reliable measurements for test applications.
  • Awọn akiyesi iwọn otutu: The gauge is designed to operate effectively within a temperature range of -40°F to 150°F. Operating outside this range may affect accuracy and longevity.
  • Glycerin Fill: The glycerin fill dampens pointer pulsation caused by vibration and pressure surges, improving readability and extending the life of the gauge movement.

5. Itọju

Regular maintenance ensures the longevity and accuracy of your vacuum gauge.

  • Ninu: Clean the exterior of the gauge, especially the polycarbonate lens, with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the lens or case.
  • Ayewo: Periodically inspect the gauge for any signs of damage, such as cracks in the lens, dents in the case, or bent pointer. Check the connection for leaks.
  • Atunṣe: While designed for long-term accuracy, professional recalibration may be necessary if the gauge is subjected to severe conditions or if accuracy is critical for your application.
  • Ibi ipamọ: When not in use, store the gauge in a clean, dry environment within its operating temperature range.

6. Laasigbotitusita

Tọkasi awọn ọran ti o wọpọ wọnyi ati awọn ojutu agbara wọn:

IsoroOwun to le FaOjutu
Kika aipeGauge exposed to over-vacuum; physical damage; extreme temperature.Verify operating conditions; inspect for damage; allow gauge to normalize temperature. Consider professional recalibration or replacement.
Pointer FluctuationSystem vibration; rapid pressure changes.The glycerin fill helps dampen this; ensure gauge is securely mounted. If severe, consider a snubber or remote mounting.
Leak at ConnectionImproperly applied thread sealant; insufficient tightening.Depressurize system, remove gauge, reapply thread sealant, and re-install, ensuring proper tightening.

7. Awọn pato

Detailed technical specifications for the ASHCROFT Vacuum Gauge (Model: 251009SW02BXLLVAC).

  • Iru Iwọn: Idanwo
  • Iwọn ipe: 2-1/2 inches
  • Ibiti: 30" Hg Vac to 0
  • Iwon Asopọmọra: 1/4" NPT
  • Ibi Asopọmọra: Isalẹ Back
  • Smallest Graduation: 0.5" Hg
  • Yiye: +/- 1.0%
  • Ohun elo ọran: 304 Irin alagbara
  • Awọ Ọran: Fadaka
  • Ohun elo Socket: 316 Irin alagbara
  • Ohun elo Tube: 316 Irin alagbara
  • Fọwọsi: Glycerin
  • Ohun elo lẹnsi: Polycarbonate
  • Ring Material: Irin ti ko njepata
  • Iwọn iwọn otutu ti nṣiṣẹ: -40°F si 150°F
  • jara: 1009
  • Awọn iwọn ọja: 3 x 3 x 3 inches
  • Ìwọ̀n Nkan: 1 iwon
  • Ilu isenbale: USA
  • UPC: 094706106517

8. Atilẹyin ọja ati Support

This ASHCROFT Vacuum Gauge comes with a 5-odun olupese ká atilẹyin ọja. For warranty claims or technical support, please contact ASHCROFT customer service. Retain your proof of purchase for warranty validation.

For further assistance or detailed technical inquiries, please refer to the official ASHCROFT webaaye tabi kan si awọn olupin ti a fun ni aṣẹ.

Awọn iwe aṣẹ ti o jọmọ - 251009SW02BXLLVAC

Ṣaajuview Ashcroft S10 & S50 RTD ati Fifi sori ẹrọ Thermocouple ati Itọsọna Itọju
Pese alaye fifi sori ẹrọ ati awọn ilana itọju fun Ashcroft S10 ati S50 RTD ati Thermocouple otutu sensosi. Ni wiwa awọn iṣọra gbogbogbo, ibi ipamọ, awọn ilana fifi sori ẹrọ pato fun awọn RTD ati awọn thermocouples, ati awọn ilana itọju lati rii daju awọn wiwọn deede ati igbesi aye gigun.
Ṣaajuview Àwọn Ìlànà Fífi Sílẹ̀ Ashcroft Model 1130 & 1140 Differential Pressure Gauge/Switch
Àwọn ìlànà ìfisílé àti àwọn àlàyé ìmọ̀-ẹ̀rọ fún Ashcroft Model 1130 àti 1140 Differential Pressure Gauges pẹ̀lú àwọn yíyàtọ̀ àṣàyàn. Ó bo àwọn ìlànà ìṣiṣẹ́, ìfisílé, àwọn ìṣọ́ra, àti àwọn wáyà yíyà.
Ṣaajuview Ashcroft B400 & B700 Snap Action Ipa Yipada fifi sori ẹrọ ati Itọsọna Itọju
Ìtọ́sọ́nà yìí fún wa ní ìwífún pàtàkì fún fífi sori ẹrọ àti ìtọ́jú àwọn ìyípadà titẹ agbára Ashcroft B400 àti B700 series. Ó bo ọjà lórí gbogbo ọjà.view, dimensions, mounting, electrical and conduit connections, setpoint adjustment procedures, and recommended practices for safe and reliable operation.
Ṣaajuview Ashcroft Skid Akole Gauges fun ọgbin Engineering | Iwọn Iwọn titẹ
Ṣawari awọn ibiti Ashcroft ti awọn iwọn titẹ Skid Akole ti a ṣe apẹrẹ fun awọn ohun elo imọ-ẹrọ ọgbin to lagbara. Ifihan irin alagbara, Hastelloy, Monel, ati awọn ohun elo Inconel pẹlu awọn alaye imọ-ẹrọ alaye.
Ṣaajuview Ashcroft G2, G3, GV & T2 Titẹ Itọnisọna Atagba
Iwe ilana fun Ashcroft G2, G3, GV, ati awọn atagba titẹ T2, ibora awọn opin itanna, wiwu, fifi sori ẹrọ, ati awọn ikilọ ailewu.
Ṣaajuview Fifi sori ẹrọ ati itọju Yiyi titẹ iyatọ Ashcroft D400 & D700 Snap Action
Ìtọ́sọ́nà pípé fún fífi sori ẹrọ àti ìtọ́jú àwọn ìyípadà titẹ ìyàtọ̀ Ashcroft D400 àti D700 series. Ó bo ìsopọ̀mọ́ra, àwọn ìsopọ̀ iná mànàmáná, àti àwọn àtúnṣe setpoint fún onírúurú àwọn àwòṣe.