Leviton 1K240-1W

Leviton Series 1000 1K240-1W Energy Meter Instruction Manual

Awoṣe: 1K240-1W | Brand: Leviton

Ọrọ Iṣaaju

The Leviton Series 1000 line of revenue-grade meters is designed for accurate measurement of power consumption. These meters are suitable for both new construction and retrofit applications, providing a simple and effective process for capturing electrical usage data. The Series 1000 meters utilize highly accurate current transformers (CTs) for revenue-grade performance, certified to ANSI standards. This model, the 1K240-1W, is a 120/240V 100A 1P3W Indoor Kit featuring split core CTs.

This manual provides essential information for the safe and correct installation, operation, and maintenance of your Leviton Series 1000 1K240-1W energy meter.

Leviton Series 1000 1K240-1W Energy Meter

Image: Leviton Series 1000 1K240-1W Indoor Kit with split core current transformers.

Eto ati fifi sori

WARNING: Installation should only be performed by a qualified electrician. Ensure all power is disconnected before beginning installation to prevent electric shock or equipment damage.

  1. Aabo Lakọkọ: Always de-energize the electrical panel or circuit where the meter will be installed. Verify with a voltagẹni tí ó ń dán an wò pé agbára ti pa.
  2. Iṣagbesori: Mount the Leviton Series 1000 meter in a suitable indoor location, typically within an electrical panel or enclosure. The unit is designed for surface mounting.
  3. Current Transformer (CT) Installation:
    • This kit includes split core CTs, which can be installed without disconnecting existing wire terminations.
    • Carefully open the split core CTs and place them around the appropriate current-carrying conductors (lines). Ensure the CTs close securely.
    • Observe the color-coded labels on the CTs for correct line/load orientation, especially for 100 Amp ati 200 Amp solid core CTs (if applicable to your specific CTs).
    • Connect the CT leads to the designated terminals on the Series 1000 meter. Up to three sets of CTs per phase can be paralleled per meter.
  4. Voltage Awọn isopọ: Connect the meter's voltage sensing wires to the appropriate voltage points in the electrical system (120/240V).
  5. Àwọn ìsopọ̀ ìbánisọ̀rọ̀ (Àṣàyàn): The meter is equipped with both Isolated Pulse Output and an RS-485 Serial Port (Modbus Native) for interface with AMR and BAS systems. Connect these as required by your system.
  6. Power Restoration and Verification: Nígbà tí gbogbo àwọn ìsopọ̀ bá wà ní ààbò, dá agbára padà sí ẹ̀rọ náà.
  7. Installation Diagnostics: Observe the meter's indicators. A red reverse phase indicator will illuminate if the meter is improperly installed. Refer to the Troubleshooting section for corrective actions. A green duty cycle light will show that the meter is collecting electrical consumption data at the appropriate rate.

Awọn ilana Iṣiṣẹ

The Leviton Series 1000 meter is designed for continuous, automatic measurement of electrical consumption. Once properly installed and powered, it begins collecting data without user intervention.

  • Gbigba data: The meter measures kilowatt-hours (kWh) and can optionally measure peak demand. This data is stored internally and can be accessed via the communication ports (Isolated Pulse Output or RS-485 Modbus).
  • Awọn Atọka Ipo
    • Green Duty Cycle Light: A steady or flashing green light indicates that the meter is actively collecting electrical consumption data correctly.
    • Red Reverse Phase Indicator: If this light is illuminated during operation, it signifies an improper installation or wiring error. Refer to the Troubleshooting section immediately.
  • Yiye: The meter provides revenue-grade accuracy, certified to ANSI C12.1 standards, ensuring reliable measurement of electrical usage.

Itoju

The Leviton Series 1000 meter is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended to ensure continued performance and safety.

  • Ayẹwo igbagbogbo: Periodically inspect the meter and its connections for any signs of physical damage, loose wiring, or overheating. Any such issues should be addressed by a qualified electrician.
  • Ninu: Keep the meter's exterior clean and free of dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • Awọn ipo Ayika: Ensure the meter operates within its specified environmental conditions (indoor use, temperature, humidity) to prevent damage and ensure accuracy.
  • Iṣẹ Iṣẹ Ọjọgbọn: For any internal servicing or recalibration, contact Leviton customer support or a certified service technician. Do not attempt to open or repair the meter yourself.

Laasigbotitusita

This section provides guidance for common issues you might encounter with your Leviton Series 1000 meter.

IsoroOwun to le FaOjutu
Red Reverse Phase Indicator is ONImproper installation or incorrect wiring of current transformers (CTs) or voltage awọn isopọ.Immediately de-energize the circuit. Re-check all CT and voltage connections against the installation diagram. Ensure CTs are correctly oriented and securely closed. If the issue persists, contact technical support.
Green Duty Cycle Light is OFF or IrregularNo power to the meter, faulty connection, or internal malfunction.Verify power supply to the meter. Check voltage connections. If power is present and connections are secure, but the light remains off or irregular, contact technical support.
No Data Output via Communication PortsIncorrect communication wiring, incorrect settings in the connected AMR/BAS system, or meter malfunction.Verify communication wiring according to the system's requirements. Check the settings of your AMR/BAS system. Ensure the meter's green duty cycle light is active. If issues persist, consult the communication protocol documentation or contact technical support.

If you encounter problems not listed here, or if the suggested solutions do not resolve the issue, please contact Leviton customer support for further assistance.

Imọ ni pato

SipesifikesonuẸ̀kúnrẹ́rẹ́
Nọmba awoṣe1K240-1W
Voltage120/240V
Ti isiyi Rating100 Amps
Alakoso / Waya1 Phase, 3 Wire (1P3W)
CT IruSplit Core
Iṣagbesori IruOke Oke
Orisun agbaraOkun Itanna
Iwọn Nkan6 iwon (isunmọ.)
Ọja Mefa19.25 x 6.5 x 12.5 inches (isunmọ.)
UPC078477597439
OlupeseLeviton
Pato sipesifikesonuUL, ANSI C12.1
AbajadeIsolated Pulse Output, RS-485 Serial Port (Modbus Native)

Alaye atilẹyin ọja

This Leviton Series 1000 1K240-1W energy meter is covered by a manufacturer's warranty. For specific details regarding the warranty period, coverage, and terms, please refer to the documentation included with your product or visit the official Leviton webojula. Jeki ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

Onibara Support

For technical assistance, troubleshooting, or warranty inquiries, please contact Leviton customer support. You can typically find contact information, including phone numbers and online support resources, on the official Leviton webojula.

  • Awọn orisun Ayelujara: Visit the Leviton website for product manuals, FAQs, and support articles.
  • Ibi iwifunni: Refer to the product packaging or the Leviton webAaye fun awọn alaye olubasọrọ iṣẹ onibara lọwọlọwọ julọ.

Awọn iwe aṣẹ ti o jọmọ - 1K240-1W

Ṣaajuview Leviton Series 6000 Multi-Function Panel Meter Installation Manual
Detailed installation guide for the Leviton Series 6000 Multi-Function Panel Meter, covering its features for electrical measurement, monitoring, and reporting, along with communication and setup instructions.
Ṣaajuview Mẹ́tà Ìwọ̀n Dídín Gíga Leviton Series 8000 Multi-Point: Fífi sori ẹrọ ati Ìwé Ìtọ́sọ́nà Olùlò
Ìtọ́sọ́nà tó péye fún Leviton Series 8000 Multi-Point High Density Meter, tó bo àwọn ìlànà ètò, àwọn ìṣọ́ra ààbò, àwọn ìlànà ìfisílé, ìṣètò, àti ìbámu pẹ̀lú ìlànà.
Ṣaajuview Leviton VerifEye Advanced Multi-Circuit Meter: Installation & Specifications (72D48, 72N48, 73D48)
Comprehensive installation guide and technical specifications for Leviton's VerifEye Advanced Multi-Circuit Meters (Models 72D48, 72N48, 73D48). Covers wiring diagrams, communication setup, pulse inputs, and safety precautions.
Ṣaajuview Itọsọna Ohun elo Leviton Mi: Ṣakoso Awọn ẹrọ Ile Smart rẹ
Ṣawari Itọsọna Ohun elo Leviton Mi lati forukọsilẹ ni irọrun, ṣepọ, ati ṣe akanṣe awọn ohun elo Decora Smart Wi-Fi rẹ ati Ile-iṣẹ Fifuye Leviton pẹlu Smart Breakers fun iṣakoso ile ọlọgbọn alailopin.
Ṣaajuview Itọsọna Ohun elo Leviton Mi: Iṣakoso Ile Smart fun Decora Smart Wi-Fi ati Awọn ile-iṣẹ fifuye
Ìtọ́sọ́nà pípéye lórí bí a ṣe lè lo àpù My Leviton fún ṣíṣàkóso àwọn ẹ̀rọ Leviton Decora Smart Wi-Fi àti àwọn ilé-iṣẹ́ Leviton Load pẹ̀lú Smart Breakers. Ó ní ìṣètò, ìṣètò, àwọn ìgbòkègbodò, àwọn ètò ẹ̀rọ, ṣíṣe àtúnṣe sí dashboard, ìmójútó agbára, àti àtìlẹ́yìn oníbàárà.
Ṣaajuview Leviton Building Manager Online (BMO) Software Loriview
Ṣe afẹri sọfitiwia Oluṣakoso Ikọle ti Leviton lori Ayelujara (BMO), logan, ojutu iṣakoso agbara orisun-awọsanma fun awọn ile iṣowo. Ṣawakiri awọn ẹya bii iworan agbara, ìdíyelé agbatọju, ijabọ ilọsiwaju, ati awọn irinṣẹ ibamu koodu, ti a ṣe lati mu lilo agbara pọ si ati dinku awọn idiyele iṣẹ.