Ranco K50Q-1127-001

Ranco K50Q-1127-001 Refrigerator Cold Control

Ilana itọnisọna

Ọrọ Iṣaaju

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Ranco K50Q-1127-001 Refrigerator Cold Control. This device is designed to regulate the temperature within refrigeration units, maintaining a range between 34°F and 55°F. Please read these instructions thoroughly before proceeding with installation or operation.

Alaye Aabo

ÌKÌLỌ̀: Ewu Ìjayà Iná mànàmáná. Yọ agbára kúrò kí o tó fi sori ẹrọ tàbí kí o ṣe iṣẹ́.

  • Always ensure the main power supply to the refrigeration unit is disconnected before attempting any installation, wiring, or maintenance procedures.
  • Installation and wiring should only be performed by a qualified technician in accordance with all local and national electrical codes.
  • Do not operate the control with damaged wiring or if the unit appears to be faulty.
  • Keep the control unit dry and away from moisture.

Ọja Pariview

The Ranco K50Q-1127-001 is a single-pole, single-throw (SPST) refrigeration control featuring a capillary tube for temperature sensing. It includes a control knob, faceplate, and mounting hardware for installation.

Ranco K50Q-1127-001 Refrigerator Cold Control unit with coiled capillary tube

Figure 1: Ranco K50Q-1127-001 Cold Control unit with its coiled capillary tube.

Ranco K50Q-1127-001 accessories including faceplate, mounting bracket, screws, and control knob

Figure 2: Included accessories: faceplate, mounting bracket, screws, wire connectors, and control knob.

Eto ati fifi sori

  1. 1. Ge Agbara:

    Before beginning any work, ensure the refrigeration unit is completely disconnected from its power source.

  2. 2. Remove Old Control (if applicable):

    Carefully remove the existing cold control, noting the wiring connections and the placement of the capillary tube. Take photographs for reference if necessary.

  3. 3. Mount the New Control:

    Use the provided mounting hardware and bracket to secure the Ranco K50Q-1127-001 control unit in the designated location. Ensure it is firmly attached.

  4. 4. Awọn isopọ onirin:

    Connect the electrical wires to the terminals on the new control. Refer to the wiring diagram of your specific refrigeration unit for correct connections. The control features SPST contacts. Ensure all connections are secure and insulated.

    Sun mo tipetipe view of the electrical terminals on the Ranco K50Q-1127-001 cold control

    Figure 3: Electrical terminals for wiring connections.

  5. 5. Capillary Tube Placement:

    The capillary tube is 47 1/4 inches long and is crucial for accurate temperature sensing. Carefully route the capillary tube to the area where temperature needs to be controlled. Avoid kinking or sharply bending the tube, as this can damage it and impair its function. The tip of the capillary tube should be securely fastened in the coldest part of the refrigerated compartment, typically near the evaporator coil, without touching it directly.

  6. 6. Install Faceplate and Knob:

    Attach the provided faceplate and control knob. Ensure the knob aligns correctly with the control shaft and the temperature markings on the faceplate.

  7. 7. Mu Agbara pada:

    Once all connections are secure and the unit is properly mounted, restore power to the refrigeration unit.

Awọn ilana Iṣiṣẹ

The Ranco K50Q-1127-001 cold control allows for temperature adjustment within a range of 34°F to 55°F.

  1. 1. Initial Setting:

    Upon initial power-up, set the control knob to a mid-range setting (e.g., '4' or '5' if numbered 0-7) to allow the unit to stabilize.

  2. 2. Ṣatunṣe iwọn otutu:

    Rotate the control knob to adjust the desired temperature. Turning the knob towards 'Colder' (or higher numbers) will decrease the temperature, while turning it towards 'Warmer' (or lower numbers) will increase the temperature. Allow several hours for the refrigeration unit to reach the new set point before making further adjustments.

  3. 3. Abojuto:

    Use an independent thermometer to verify the actual temperature inside the refrigerated compartment. Adjust the control as needed to achieve and maintain the desired temperature.

Itoju

Regular maintenance helps ensure the longevity and optimal performance of your cold control.

  • Ninu: Periodically inspect the control unit and its surroundings for dust or debris. Gently clean with a dry, soft cloth. Ensure no moisture enters the control unit.
  • Capillary Tube Inspection: Annually inspect the capillary tube for any signs of damage, kinks, or corrosion. Ensure it remains securely fastened in its sensing location.
  • Awọn Isopọ Itanna: During routine refrigeration unit maintenance, verify that all electrical connections to the cold control are tight and free from corrosion.

Laasigbotitusita

If you experience issues with your refrigeration unit's temperature control, consider the following common troubleshooting steps:

Isoro Owun to le Fa Ojutu
Refrigeration unit not cooling Control set too high; faulty wiring; damaged capillary tube; control failure. Adjust control to a lower setting. Check wiring connections. Inspect capillary tube for damage. If issues persist, professional diagnosis may be required.
Refrigeration unit freezing contents Control set too low; capillary tube improperly placed; control failure. Adjust control to a higher setting. Verify capillary tube placement. If issues persist, professional diagnosis may be required.
Iwọn otutu n yipada ni ọpọlọpọ Capillary tube not sensing correctly; control unit faulty. Ensure capillary tube is properly positioned and undamaged. Consider professional inspection if fluctuations continue.

For complex issues or if you are unsure about any troubleshooting steps, it is recommended to contact a qualified refrigeration technician.

Awọn pato

  • Awoṣe: K50Q-1127-001
  • Control Temperature Range: 34°F si 55°F (1.1°C si 12.8°C)
  • Cold Off Temperature: 35.6°F (2°C)
  • Cold On Temperature: 41°F (5°C)
  • Fọọmu Olubasọrọ: SPST (Ọpá Kanṣoṣo, Jíjá Ẹyọ Kan)
  • Gigun Opopona: 47 1/4 inches (120 cm)
  • Capillary Type: Oludari
  • Ni kikun fifuye Lọwọlọwọ: 10/6 A
  • Titiipa Rotor Amps: 80 A
  • Apapọ Giga: 2 1/2 inches (6.35 cm)
  • Apapọ Gigun: 1 1/8 inches (2.86 cm)
  • Pẹlu: Faceplate, Mounting Hardware

Atilẹyin ọja ati Support

For warranty information, please refer to the documentation provided with your purchase or contact the seller directly. For technical support or further assistance, please reach out to the Ranco manufacturer or your product supplier.

Awọn iwe aṣẹ ti o jọmọ - K50Q-1127-001

Ṣaajuview Ranco ETC Meji Stage Itanna otutu Iṣakoso - NEMA Iru 4X fifi sori Data
Awọn alaye fifi sori ẹrọ, awọn pato, iṣẹ ṣiṣe, ati laasigbotitusita fun Ranco ETC Meji Stage Itanna otutu Iṣakoso, NEMA Iru 4X. Iṣakoso yii jẹ apẹrẹ fun HVAC ti iṣowo ati itutu agbaiye, ti o funni ni meji-stage ni iṣakoso iwọn otutu, ifihan LCD, siseto bọtini foonu, ati apade omi ti NEMA 4X fun lilo ita gbangba.
Ṣaajuview Ranco ETC Single StagAwọn ilana fifi sori ẹrọ Iṣakoso Iwọn otutu itanna e
Ìtọ́sọ́nà ìfisílẹ̀, ìṣiṣẹ́, àti ìṣòro tó péye fún Ranco ETC Single StagIṣakoso Iwọn otutu Itanna. O bo awọn alaye ọja, awọn ohun elo, awọn ẹya ara ẹrọ, awọn pato, aṣẹ, siseto, iyipada titiipa, awọn aworan onirin, ati alaye sensọ fun awọn eto HVAC ati firiji.
Ṣaajuview Ranco, Johnson Iṣakoso, ati Danfoss Refrigeration katalogi
Katalogi okeerẹ ti Ranco, Awọn iṣakoso Johnson, ati iwọn otutu Danfoss ati awọn iṣakoso titẹ, pẹlu awọn iṣakoso iwọn titẹ kekere, awọn iṣakoso titẹ kekere-giga, awọn iṣakoso itanna, awọn iṣakoso defrost, ati awọn ẹya ẹrọ fun awọn eto itutu.
Ṣaajuview Ranco Nikan titẹ Iṣakoso fifi sori Data
Data fifi sori ẹrọ fun awọn iṣakoso titẹ ọkan Ranco (010, 011, 016, 020). Apejuwe ni wiwa, ohun elo, fifi sori ẹrọ, wiwu, ati awọn eto iṣakoso fun ọpọlọpọ awọn firiji ati awọn sakani titẹ.
Ṣaajuview Ranco O10 / O11 / O16 / O20 Nikan titẹ Iṣakoso fifi sori Data
Awọn alaye fifi sori ẹrọ pipe, wiwu, awọn eto, ati awọn pato fun Ranco O10, O11, O16, ati O20 awọn iṣakoso titẹ ẹyọkan ti a lo ninu itutu agbaiye iṣowo ati awọn ọna ṣiṣe afẹfẹ. Pẹlu awọn ilana iṣagbesori, itọju capillary, wiwọ iṣakoso, awọn ilana atunṣe, ati awọn alaye ni pato.
Ṣaajuview Ranco Isalẹ Idasonu Trailer Isẹ, Itọju & Awọn ẹya ara Afowoyi
Itọsọna okeerẹ fun Awọn olutọpa Idasonu Ranco Isalẹ ti o bo isẹ, itọju, awọn ẹya, itanna, idaduro afẹfẹ, ati awọn eto idadoro. Pataki fun lilo to dara ati itọju.