Notifier NBG-12LX

Notifier NBG-12LX Fire Alarm Addressable Pull Station User Manual

Model: NBG-12LX

1. Ọja Ipariview

The Notifier NBG-12LX is a robust, addressable dual-action manual pull station designed for use in fire alarm systems. It provides a clear and immediate means for occupants to manually initiate a fire alarm signal, alerting others and triggering emergency response procedures. Its durable construction and straightforward operation make it an essential component for fire safety in various building types.

Iwaju view of the Notifier NBG-12LX fire alarm pull station, red with 'FIRE' and 'PUSH IN PULL DOWN' labels.

olusin 1: Iwaju view of the Notifier NBG-12LX Manual Pull Station.

This image displays the front of the Notifier NBG-12LX, highlighting its red casing, the prominent "FIRE" label, and the "PUSH IN PULL DOWN" instructions for activation. A keyhole for resetting the device is visible at the bottom right.

2. Eto ati fifi sori

Installation of the NBG-12LX should only be performed by qualified personnel in accordance with all local and national electrical and fire codes. This device is designed for wall mounting and requires connection to a compatible fire alarm control panel.

2.1 Iṣagbesori

  1. Select a suitable mounting location that is easily accessible and visible, typically near exits or stairwells, as per local fire safety regulations.
  2. Rí i dájú pé ojú ibi tí a fi pamọ́ náà tẹ́jú tí ó sì ní ààbò.
  3. Use appropriate screws (such as those provided, if applicable) to secure the pull station to the wall or electrical box.
Notifier NBG-12LX pull station with instruction manual, key, and mounting screws.

Figure 2: Notifier NBG-12LX components including manual, key, and screws.

This image shows the Notifier NBG-12LX pull station alongside its instruction manual, a key for resetting the device, and a small bag containing mounting screws, illustrating the items typically included for installation.

2.2 Onirin

The NBG-12LX is an addressable device and must be wired to an addressable fire alarm control panel. Refer to the specific wiring diagrams provided with your fire alarm control panel and the NBG-12LX installation manual for detailed instructions.

  • Connect the appropriate field wiring to the terminal block on the back of the pull station.
  • Ensure all connections are secure and comply with wiring standards.
  • Verify proper addressing of the device on the fire alarm control panel.
Pada view of the Notifier NBG-12LX fire alarm pull station showing wiring terminals.

olusin 3: Ẹyìn view of the Notifier NBG-12LX with wiring terminals.

This image displays the back of the Notifier NBG-12LX, revealing the internal wiring terminals and a strip gauge, which are crucial for proper electrical connection to the fire alarm system.

3. Awọn ilana Iṣiṣẹ

The Notifier NBG-12LX is a dual-action pull station, meaning it requires two distinct actions to activate the alarm, reducing the likelihood of accidental activation.

3.1 Activating the Alarm

In the event of a fire or other emergency requiring immediate evacuation:

  1. Titari si: Firmly push the center bar of the pull station inwards.
  2. Fa isalẹ: Once pushed in, pull the bar downwards until it latches in the activated position.

This action will send an alarm signal to the fire alarm control panel, initiating the building's emergency procedures, including sounding alarms and notifying emergency services.

4. Itọju

Regular maintenance ensures the reliable operation of your Notifier NBG-12LX pull station. All maintenance should be performed by trained and authorized personnel.

4.1 Awọn sọwedowo baraku

  • Ayewo wiwo: Periodically inspect the pull station for any signs of physical damage, tampering, or obstruction. Ensure all labels are legible.
  • Idanwo Iṣiṣẹ: Conduct functional tests as required by local fire codes and manufacturer recommendations (e.g., annually). This typically involves activating the pull station and verifying that the alarm signal is received by the control panel.

4.2 Resetting the Pull Station

After activation, the NBG-12LX must be reset using the provided key.

  1. Insert the key into the keyhole located on the bottom right of the pull station.
  2. Turn the key to reset the pull station to its normal, non-alarm state.
  3. Yọ bọtini kuro.

Ensure the fire alarm control panel is also reset after the pull station has been restored.

5. Laasigbotitusita

If you encounter issues with your Notifier NBG-12LX, consult the following common troubleshooting steps. For complex issues, contact a qualified fire alarm technician.

IsoroOwun to le FaOjutu
Pull station does not activate alarm.Incorrect wiring, device not addressed, control panel issue, physical damage.Verify wiring connections. Check device addressing on control panel. Inspect for damage. Consult control panel manual.
Pull station cannot be reset.Key not fully inserted, internal mechanism jammed, control panel not reset.Ensure key is fully inserted and turned. Gently attempt to reset. Reset the fire alarm control panel first.
Àwọn ìkìlọ̀ èké.Accidental activation, faulty device, wiring issue.Educate users on proper activation. Inspect device for damage. Check wiring for shorts or loose connections.

6. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
BrandOlufunfun
Nọmba awoṣeNBG-12LX
IruAdirẹsi Afowoyi Fa Station
IsẹDual Action (Push In, Pull Down)
Reset MechanismKeyed Operation
Àwọ̀Pupa
IṣagbesoriÒgiri Ògiri
Ohun eloṢiṣu
Iwọn Nkan6.4 iwon (isunmọ 0.4 lbs)
Ọja Mefa5.5 x 4 x 2 inches
Orisun agbaraCorded Electric (via FACP)
Ti beere awọn batiri?Rara
UPC020103106041
Packaging of Notifier NBG-12LX showing product details and certifications.

Figure 4: Notifier NBG-12LX packaging with specifications and certifications.

This image displays the product packaging, which lists key features such as "Dual Action," "Key Lock Reset," "Addressable," and "Screw Terminals," along with UL and FM certifications and manufacturer contact information.

7. Atilẹyin ọja ati Support

For specific warranty information, please refer to the documentation included with your purchase or contact Notifier directly. Notifier products are designed for reliability and performance.

For technical support, service, or further inquiries, please contact Notifier customer service or a certified fire alarm system professional.

  • Olupese: Notifier nipasẹ Honeywell
  • Webojula: www.notifier.com
  • Foonu: (203) 484-7161
  • Faksi: (203) 484-7118

Awọn iwe aṣẹ ti o jọmọ - NBG-12LX

Ṣaajuview Notifier NBG-12LX Adirẹsi Fa ibudo fifi sori ati isẹ ti Itọsọna
Iwe yii n pese awọn ilana alaye fun fifi sori ẹrọ, wiwu, ati iṣẹ ti Notifier NBG-12LX Adirẹsi Ibusọ Fa. O ni wiwa tito adirẹsi, awọn asopọ onirin, iṣagbesori, ati iṣẹ-ṣiṣe fa ibudo afọwọṣe meji-igbese.
Ṣaajuview Olufitonileti NBG-12LPS Ibusọ Ifi ami-iṣaaju: Fifi sori ẹrọ, Iṣẹ, ati Awọn pato
Itọsọna okeerẹ si Notifier NBG-12LPS ati awọn ibudo afọwọṣe NBG-12LPSP. Awọn ideri yipada awọn iwọn olubasọrọ, fifi sori ẹrọ, wiwiri, iṣiṣẹ, mimu iṣẹ-meji, ami ami-iṣaaju ati awọn iṣẹ itaniji gbogbogbo, ibamu ADA, ati awọn ilana tunto fun awọn eto itaniji ina.
Ṣaajuview Notifier NBG-12LO/-12LOB Afowoyi Fa Ibusọ fun Awọn ohun elo ita gbangba
Iwe yii pese alaye alaye lori Notifier NBG-12LO/-12LOB Afowoyi Fa Ibusọ, apẹrẹ fun awọn ohun elo ita gbangba. O ni wiwa apejuwe ọja, awọn ẹya ara ẹrọ, iyipada olubasọrọ olubasọrọ, asomọ ilẹkun ati awọn ilana isọdọmọ, awọn itọnisọna wiwi, awọn ibeere fifi sori ita gbangba, ati awọn itọnisọna iṣẹ. Ibusọ fifa jẹ ti kii ṣe koodu, awoṣe iṣe-meji pẹlu atunto titiipa bọtini, atokọ UL, ati ibamu ADA.
Ṣaajuview NOTIFIER AFP-200 Analog Fire Panel - Technical Specifications and Features
Alaye ti pariview of the NOTIFIER AFP-200 Analog Fire Panel, covering its features, system capacity, specifications, compatible devices, and programming methods. Includes agency listings and product information.
Ṣaajuview NOTIFIER NFS-3030 Intelligent Addressable Fire Alarm System | Technical Data Sheet
Explore the NOTIFIER NFS-3030, an intelligent addressable fire alarm control panel from the ONYX Series. Engineered for medium to large facilities, it offers advanced detection, modularity, and extensive device support for critical fire safety applications.
Ṣaajuview Notifier AM-8000 Ni oye Adirẹsi Ina erin fifi sori Afowoyi
Itọsọna fifi sori ẹrọ yii n pese itọnisọna okeerẹ fun Notifier AM-8000 Intelligent Addressable Fire erin eto. O ni wiwa eto loriview, awọn alaye imọ-ẹrọ, awọn ẹya itanna, awọn ilana fifi sori ẹrọ, awọn aworan wiwu, awọn iṣiro ipese agbara, idanwo, ati itọju.