Johnson Controls V-9012-1

Ìwé Ìtọ́ni Ìtọ́sọ́nà fún Ìṣàkóṣo Àfòmọ́ Solenoid V-9012-1 ti Johnson

Model: V-9012-1

1. Ifihan

This manual provides detailed instructions for the installation, operation, and maintenance of the Johnson Controls V-9012-1 E/P Solenoid Relay. This device is designed to convert an electrical signal into a pneumatic output, controlling air pressure based on a 12 VDC input. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Alaye Aabo

Adherence to safety precautions is crucial for preventing injury and damage to the equipment. Always follow local codes and regulations.

  • Oṣiṣẹ ti o peye: Installation and servicing must be performed by qualified and experienced personnel only.
  • Aabo Itanna: Disconnect all power to the device and associated equipment before performing any wiring or maintenance. Ensure proper grounding.
  • Pneumatic Safety: Depressurize all pneumatic lines before making or breaking connections. Wear appropriate personal protective equipment.
  • Awọn ipo Ayika: Do not expose the device to conditions outside its specified operating range (temperature, humidity, pressure).

3. Ọja Ipariview

The Johnson Controls V-9012-1 is an Electro-Pneumatic (E/P) Solenoid Relay that converts a 12 VDC electrical input into a pneumatic control signal. It is commonly used in industrial applications to manage air pressure for actuators or other pneumatic devices.

3.1. Key Awọn ẹya ara ẹrọ

  • 12 VDC Input for electrical control.
  • Solenoid Valve functionality for precise pneumatic regulation.
  • Relay operation for switching pneumatic states.
  • Maximum input current of 50 mA.

3.2. Components and Labeling

Refer to the image below for a visual representation of the V-9012-1 Solenoid Valve Relay and its key labeled components.

Johnson Controls V-9012-1 E/P Solenoid Relay with labels

Figure 1: Johnson Controls V-9012-1 E/P Solenoid Relay

The image displays the Johnson Controls V-9012-1 E/P Solenoid Relay. Key labels visible on the device include:

  • V-9012-1 E/P SOLENOID RELAY: Identifies the model and type of device.
  • PAT 4,770,200 and PAT 4,804,009: Patent numbers associated with the product.
  • BO TERM. 1 (RED): Indicates the first electrical terminal, typically for the positive 12 VDC input.
  • 12 V.D.C. INPUT (50 mA. MAX.): Specifies the required input voltage ati ki o pọju lọwọlọwọ.
  • BO TERM. 2 (BLK) RESISTOR: Indicates the second electrical terminal, typically for the negative connection, and notes the presence of a resistor.
  • Ipese: The inlet port for the pneumatic supply pressure.
  • ACTUATOR: The outlet port for the controlled pneumatic pressure to the actuator.
  • +12 V.D.C. PRESS.: Indicates that a +12 VDC input results in a 'PRESS' (pressure) state.
  • 0 V.D.C. HOLD: Indicates that 0 VDC input results in a 'HOLD' state.
  • -12 V.D.C. EXHAUST: Indicates that a -12 VDC input results in an 'EXHAUST' state.

4. Eto ati fifi sori

Proper installation is critical for the correct functioning of the V-9012-1 Solenoid Relay.

4.1. Pre-Fifi sọwedowo

  • Verify that the power supply matches the device's requirements (12 VDC).
  • Inspect the device for any visible damage from shipping.
  • Ensure all necessary tools and fittings are available.

4.2. Iṣagbesori

Mount the solenoid relay securely in a location that is free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections.

4.3. Awọn itọnisọna Wiring

Tẹle awọn igbesẹ wọnyi fun awọn asopọ itanna:

  1. Ensure the power source is completely disconnected.
  2. Connect the positive (+) 12 VDC power supply wire to BO TERM. 1 (RED).
  3. Connect the negative (-) 12 VDC power supply wire to BO TERM. 2 (BLK). Note that this terminal includes a resistor.
  4. Daju pe gbogbo awọn asopọ ti wa ni aabo ati idabobo daradara.

4.4. Pneumatic Connections

Follow these steps for pneumatic connections:

  1. Connect the main pneumatic supply line to the port labeled IPESE. Ensure the supply pressure is within the device's specified operating range.
  2. Connect the line leading to the pneumatic actuator or controlled device to the port labeled Oṣere.
  3. Check all pneumatic connections for leaks after pressurizing the system.

5. Isẹ

The V-9012-1 Solenoid Relay operates based on the applied electrical input voltage, controlling the pneumatic output to the actuator.

  • +12 VDC Input: When a positive 12 VDC is applied to the input terminals, the relay will enter a 'PRESS' state, allowing supply pressure to flow to the actuator.
  • 0 VDC Input: When 0 VDC (no voltage) is applied, the relay will enter a 'HOLD' state, maintaining the current pneumatic output.
  • -12 VDC Input: When a negative 12 VDC is applied, the relay will enter an 'EXHAUST' state, releasing pressure from the actuator.

Ensure that the control system provides the correct voltage signals for the desired pneumatic response.

6. Itọju

The Johnson Controls V-9012-1 Solenoid Relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and optimal performance.

  • Ayẹwo deede: Periodically inspect the device for any signs of wear, corrosion, or damage to the housing, wiring, and pneumatic connections.
  • Ninu: Keep the exterior of the device clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Iduroṣinṣin asopọ: Verify that all electrical and pneumatic connections remain tight and secure.
  • Iṣẹ Ọjọgbọn: For internal issues or complex repairs, contact a qualified service technician or Johnson Controls support. Do not attempt to disassemble the unit.

7. Laasigbotitusita

This section provides solutions to common issues that may arise during the operation of the V-9012-1 Solenoid Relay.

IsoroOwun to le FaOjutu
Device does not respond to electrical input.Kò sí agbára, ìpele tí kò tọ́tage, loose wiring, internal fault.Check 12 VDC power supply. Verify wiring connections to Terminals 1 and 2. Ensure correct polarity. If problem persists, contact support.
Pneumatic output is incorrect or inconsistent.Insufficient supply pressure, clogged lines, leaks in pneumatic connections, internal valve issue.Check pneumatic supply pressure. Inspect lines for obstructions or leaks. Ensure correct electrical input for desired pneumatic state.
Ẹrọ ti wa ni igbona pupọ.Excessive current, improper ventilation, continuous operation beyond duty cycle.Verify input current does not exceed 50 mA. Ensure adequate airflow around the device. Review application for duty cycle requirements.

8. Awọn pato

Technical specifications for the Johnson Controls V-9012-1 E/P Solenoid Relay:

ParamitaIye
Nọmba awoṣeV-9012-1
IšẹE/P Solenoid Relay
Iṣagbewọle Voltage12 VDC
Ti o pọju Input Lọwọlọwọ50 mA
Pneumatic StatesPress (+12 VDC), Hold (0 VDC), Exhaust (-12 VDC)
OlupeseJohnson idari
Iwọn Nkan6.4 iwon
Ọjọ Akọkọ WaOṣu Keje 5, Ọdun 2012

9. Atilẹyin ọja ati Support

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly through their official website or customer service channels. Keep your purchase receipt and product model number readily available when seeking support.

Awọn iwe aṣẹ ti o jọmọ - V-9012-1

Ṣaajuview Johnson Ṣakoso Awọn Idẹ Cage gige Awọn falifu: 3/4 si 2 Inch Itọsọna Ọja
Itọsọna imọ-ẹrọ okeerẹ fun Johnson Awọn iṣakoso Bronze Cage Trim Valves (3/4 si 2 Inch), awọn ẹya alaye, pneumatic ati awọn aṣayan actuator ina, awọn pato, iṣẹ ṣiṣe, fifi sori ẹrọ, ati awọn ẹya atunṣe fun awọn ohun elo HVAC.
Ṣaajuview Johnson Ṣàkóso EP-8000 Series Electro-Pneumatic Transducers: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ, Fífi sori ẹrọ, àti Iṣẹ́
Ìwé ìròyìn ìmọ̀-ẹ̀rọ tó kún rẹ́rẹ́ fún àwọn ẹ̀rọ amúṣẹ́dá EP-8000 Series ti Johnson Controls. Ó bo ọjà náà lórí rẹ̀.view, iṣiṣẹ́, ìwọ̀n, fifi sori ẹrọ, okun waya, iwọntunwọnsi, ati awọn alaye imọ-ẹrọ fun awọn ohun elo iṣakoso ile-iṣẹ.
Ṣaajuview Ìtọ́sọ́nà Fífi sori Àwọn Fáìfù Ìdarí Idẹ VG7000 Series
Àwọn ìlànà ìfisílé àti àwọn ìlànà ìmọ̀-ẹ̀rọ tó péye fún àwọn fáfà ìṣàkóso idẹ Johnson VG7000 Series, tí a ṣe fún ṣíṣàkóso omi àti ìgbóná nínú àwọn ètò HVAC. Ó ní ìwọ̀n fáfà, àwọn ohun èlò, àti àwọn pàrámítà ìṣiṣẹ́.
Ṣaajuview Johnson Iṣakoso àtọwọdá Tunṣe Parts Catalog
Katalogi okeerẹ ti n ṣalaye awọn ẹya rirọpo, pẹlu awọn diaphragms, awọn ohun elo orisun omi, awọn ohun elo iṣakojọpọ, awọn ohun elo isọdọtun, ati awọn paati miiran fun titobi Johnson Awọn iṣakoso pneumatic ati awọn falifu ina.
Ṣaajuview Ìtọ́sọ́nà Ìfisílẹ̀ Ẹ̀rọ Ìṣàkóṣo Johnson ti CSD Series Split Core Current Device
Ìtọ́sọ́nà ìfisílé àti ìmọ̀ ẹ̀rọ fún àwọn ẹ̀rọ ìṣàkóṣo CSD Series split core current devices (CSD-CF0J1-1, CSD-CA1G1-1) pẹ̀lú relay. Ó bo àwọn ohun èlò, wáyà, ìṣàtúnṣe, ìṣòro, àti àwọn ìlànà fún ìṣàyẹ̀wò current industry.
Ṣaajuview Ìtọ́sọ́nà Fífi Fáìfù Ìdarí VP1000 Compact Globe (Axial) sori ẹrọ
Ìtọ́sọ́nà ìfisílé fún fáàfù ìdarí Johnson Controls VP1000 Compact Globe (Axial), tí ó bo àwọn ìwọ̀n 1/2 Inch sí 1 1/4 Inch (DN15-DN32). Ó pèsè àwọn ìlànà ìmọ̀-ẹ̀rọ, àwọn ìlànà ìfisílé, àti ìwífún nípa ìtọ́jú.