1. Ifihan
This manual provides essential instructions for the safe and effective use of the Testo 0560 8312 830-T1 IR Thermometer. This device is designed for non-contact measurement of surface temperatures in various industrial and trade applications. It features 12:1 optics and a dual laser for precise targeting, allowing for accurate temperature readings even on smaller objects from a safe distance.
2. Alaye Aabo
Please read this section carefully before operating the device to ensure safe and proper use.
- Do not point the laser directly into eyes or at other people.
- Ma ṣe lo ẹrọ naa ni awọn bugbamu bugbamu.
- Protect the device from extreme temperatures, impacts, and strong vibrations.
- Jeki ẹrọ naa mọ ki o gbẹ.
- Lo ẹ̀rọ náà fún ète tí a fẹ́ lò gẹ́gẹ́ bí a ṣe ṣàlàyé rẹ̀ nínú ìwé ìtọ́ni yìí nìkan.
- Awọn atunṣe yẹ ki o ṣee ṣe nipasẹ oṣiṣẹ ti a fun ni aṣẹ nikan.
3. Ọja Ipariview
The Testo 830-T1 IR Thermometer is a handheld device designed for quick and accurate non-contact temperature measurements.

Figure 1: Testo 830-T1 Infrared Thermometer with included battery.

olusin 2: Iwaju view of the Testo 830-T1, showing the display, measurement trigger, and control buttons.
3.1 irinše
- Sensọ infurarẹẹdi: Located at the front of the device, used for non-contact temperature measurement.
- Awọn Atọka Laser Meji: Two laser dots indicate the measurement spot size.
- Ifihan: Shows temperature readings, measurement units, battery status, and other indicators.
- Ohun tó ń fa ìwọ́n: Ó ń mú ìwọ̀n àti lésà ṣiṣẹ́.
- Awọn bọtini Iṣakoso: For navigating menus, adjusting settings (e.g., emissivity, units), and accessing functions like MIN/MAX.
- Abala Batiri: Ti wa ni apa mu fun fifi sori batiri.
4. Eto
4.1 Fifi sori batiri
- Wa ideri ibi ipamọ batiri naa lori ọwọ ti iwọn otutu naa.
- Ṣii ideri.
- Insert two AAA batteries, ensuring correct polarity (+/-). The device requires 2 AAA batteries, which are included.
- Pa ideri batiri naa ni aabo.
4.2 Initial Power-On and Unit Selection
Upon first use or after battery replacement, the device will power on. You may need to select your preferred temperature unit (Celsius or Fahrenheit).
- To change units: Typically, this involves pressing and holding a specific button (often the 'Mode' or 'Set' button, or an arrow button) while the device is off, then powering it on, or accessing a menu option. Refer to the on-screen prompts or the official Testo documentation for the exact procedure for your specific device firmware, as methods can vary.
5. Awọn ilana Iṣiṣẹ
5.1 Gbigba Idiwon
- Point the infrared sensor towards the target object.
- Press and hold the measurement trigger. The dual laser pointers will activate, indicating the measurement spot.
- The temperature reading will appear on the display.
- Release the trigger to hold the last measured value (HOLD function).

Figure 3: The Testo 830-T1 in use, measuring the surface temperature of a radiator.
5.2 Understanding 12:1 Optics and Dual Laser
The 12:1 optics mean that at a distance of 12 inches, the measurement spot diameter is 1 inch. The dual laser pointers converge at the center of this measurement spot, helping you accurately identify the area being measured. This is particularly useful for measuring smaller objects or from a greater distance.
5.3 MIN / Max Išė
The device can display the minimum and maximum temperatures recorded during a continuous measurement. This function is useful for monitoring temperature fluctuations over a period.
- To activate MIN/MAX: Press the appropriate button (refer to your device's specific button layout, often an arrow or 'Mode' button) while taking a measurement. The display will cycle through current, minimum, and maximum values.
5.4 Àtúnṣe Ìtújáde Ìtújáde
Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. For accurate readings, adjust the emissivity setting on your thermometer to match the material being measured. Common emissivity values:
- 0.95 (default for many devices): Most organic materials, painted surfaces, water, plastic.
- 0.85-0.90: Concrete, brick, rough wood.
- 0.60-0.70: Polished metals (can vary significantly).
Consult an emissivity table for specific materials. Incorrect emissivity settings will lead to inaccurate temperature readings.
6. Itọju
6.1 Ninu
Láti rí i dájú pé iṣẹ́ rẹ̀ dára jù àti pé ó pẹ́ tó, jẹ́ kí ẹ̀rọ náà mọ́ tónítóní.
- Wipe the device exterior with a clean, damp asọ. Ma ṣe lo abrasive ose tabi epo.
- Carefully clean the infrared lens with a soft, lint-free cloth or a lens cleaning wipe. Avoid scratching the lens.
6.2 Batiri Rirọpo
When the battery indicator on the display shows low power, replace the batteries promptly to avoid interruption of operation. Follow the battery installation steps in Section 4.1.
6.3 Ibi ipamọ
Store the thermometer in a dry, dust-free environment within the recommended temperature range (refer to specifications). If storing for extended periods, remove the batteries to prevent leakage.
7. Laasigbotitusita
If you encounter issues with your Testo 830-T1, refer to the following common problems and solutions:
- Ẹrọ ko ni agbara lori:
- Check if batteries are correctly inserted with proper polarity.
- Rọpo awọn batiri pẹlu awọn tuntun.
- Awọn kika ti ko pe:
- Ensure the infrared lens is clean.
- Verify the emissivity setting matches the target material.
- Ensure the measurement distance is appropriate for the target size (12:1 optics).
- Avoid measuring through glass or highly reflective surfaces.
- Lesa ko han:
- Ṣayẹwo ipele batiri.
- Ensure the measurement trigger is pressed.
If problems persist, contact Testo customer support for assistance.
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | 0560 8312 |
| Brand | Testo |
| Optics | 12:1 |
| Lesa | Dual Laser Spot Marking |
| Pataki Ẹya | Non-olubasọrọ wiwọn |
| Ifihan Iru | Oni-nọmba |
| Orisun agbara | Awọn batiri AAA 2 (pẹlu) |
| Ọja Mefa | 2.95 x 1.5 x 7.48 inches |
| Iwọn Nkan | 0.04 iwon |
| Ohun elo ita | Ṣiṣu |
| Awọn irinše to wa | Testo T2 Infrared Thermometer |
| Pato sipesifikesonu | CE, FCC, ISO 9001 |
| Asopọmọra Technology | USB (Note: Functionality may require specific software/cables, not detailed here) |
9. Atilẹyin ọja ati Support
For warranty information, technical support, or service inquiries, please contact Testo SE & Co. directly. Details regarding specific warranty periods and terms are typically provided with the product packaging or on the manufacturer's official webojula.
Olupese: Testo SE & Co.
Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.





