1. Ifihan
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of the Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter. This device is engineered for precise electrical measurements in potentially hazardous environments, offering robust performance and advanced safety features.
2. Alaye Aabo
WARNING: Read and understand all safety information before using this product. Failure to do so may result in serious injury or death.
2.1 Gbogbogbo Awọn Itọsọna Aabo
- Always use the multimeter with the specified test leads and accessories.
- Do not use the multimeter if it appears damaged or is operating abnormally.
- Ṣe akiyesi gbogbo awọn koodu aabo agbegbe ati ti orilẹ-ede.
- Rí i dájú pé a yan iṣẹ́ àti ìwọ̀n tó yẹ kí a tó ṣe àwọn ìwọ̀n.
- Avoid working alone in hazardous environments.
2.2 Intrinsically Safe Operation
The Fluke 28IIEX/ETL is designed for use in hazardous locations classified as:
- ATEX: II 2 G Ex ia IIC T4 Gb, II 2 D Ex ia IIIC T130°C Db, I M1 Ex ia I Ma
- NEC-500: Class I, Div 1, Groups A-D, 130 °C
- IEXEx: Ex ia IIC T4 Gb, Ex ia IIIC T130°C Db, Ex ia I Ma
These ratings ensure the device will not ignite explosive atmospheres under normal or fault conditions. Always ensure the device is used within its specified environmental and electrical limits for intrinsically safe operation.
2.3 Electrical Safety Ratings
The multimeter meets International Electrotechnical Commission (IEC) safety standard 61010 and is certified for:
- Category III 1000V: For measurements on building circuit installations (e.g., service panel parts, branch circuits, fixed installations).
- Category IV 600V: For measurements at the origin of the installation (e.g., electricity meters, primary over-current protection equipment).
- Ipele Idoti 2: Fun inu ile lilo.
2.4 Ayika Idaabobo
The device is Ingress Protection (IP) certified IP67, meaning it is waterproof, dust-proof, and drop-proof, suitable for harsh industrial environments.
3. Ọja Ipariview
The Fluke 28IIEX/ETL is a robust digital multimeter designed for reliability and accuracy. It features a large LCD display with a two-level bright white backlight for visibility in various lighting conditions.

olusin 1: Iwaju view of the Fluke 28IIEX/ETL Digital Multimeter. The image displays the device with its red protective holster, gray body, LCD screen showing '28.20 V AC', and the rotary dial for function selection. Below the dial are the input jacks for current, voltage, and common connections, along with safety warnings and certifications.
3.1 Key Awọn ẹya ara ẹrọ
- True-RMS measurements for accurate readings on linear and non-linear loads.
- Auto- and manual-ranging capabilities.
- Awọn iwọn voltage, current, resistance, capacitance, frequency, temperature, conductance, and duty cycle.
- Performs continuity and diode tests.
- Low-pass filter for accurate voltage and frequency measurements on variable-speed motor drives.
- MIN/MAX/AVG and Peak Capture functions to record transients and measurement variations.
- Relative mode to remove test lead interference.
- Backlit keypad buttons and display for low-light conditions.
- Audible alarm for incorrect test lead connection.
4. Eto
4.1 Fifi sori batiri
The Fluke 28IIEX/ETL requires four (4) AA alkaline batteries for operation. To install or replace batteries:
- Rii daju pe multimeter ti wa ni pipa.
- Yọ holster roba aabo.
- Locate and open the battery compartment cover on the rear of the device.
- Insert four new AA alkaline batteries, observing the correct polarity markings.
- Securely close the battery compartment cover and reattach the holster.
4.2 Nsopọ Awọn itọsọna Igbeyewo
Always connect test leads to the appropriate input jacks for the measurement being performed. The multimeter will sound an alarm if leads are connected incorrectly for the selected function.
- COM Jack: Connect the black test lead to the common (COM) jack for all measurements.
- VΩHz Jack: Connect the red test lead to this jack for voltage, resistance, frequency, capacitance, and diode tests.
- mAµA Jack: Connect the red test lead to this jack for current measurements up to 400mA. This input is fused.
- 10A Max Fused Jack: Connect the red test lead to this jack for current measurements up to 10A. This input is fused.
5. Awọn ilana Iṣiṣẹ
Turn the rotary switch to the desired function. The multimeter defaults to auto-ranging mode, automatically selecting the correct measurement range. Press the 'RANGE' button to switch to manual ranging.
5.1 Idiwọn Voltage (AC/DC)
- Connect the black lead to COM and the red lead to VΩHz.
- Turn the rotary switch to V~ (AC Voltage) tabi V- (DC Voltagati).
- So àwọn ìtọ́wò ìdánwò pọ̀ mọ́ ara wọn ní gbogbo àyíká tàbí ohun èlò tí a fẹ́ wọ̀n.
5.2 Measuring Current (mA/A/µA)
WARNING: Never attempt to measure current by connecting the multimeter in parallel with a voltage source. This can damage the meter and cause injury.
- Connect the black lead to COM. Connect the red lead to mAµA for small currents or 10A Max Fused for larger currents.
- Turn the rotary switch to mA/A~ (AC Current) or mA/A- (DC Current).
- Ṣí àyíká náà kí o sì so multimeter pọ̀ ní ìtẹ̀léra pẹ̀lú ẹrù náà.
5.3 Ìwọ̀n Àìdádúró (Ω)
- Connect the black lead to COM and the red lead to VΩHz.
- Yi iyipada iyipo pada si Ω.
- Rí i dájú pé agbára ìṣiṣẹ́ náà kò pọ̀. So àwọn okùn ìdánwò náà pọ̀ mọ́ ara wọn.
5.4 Igbeyewo Ilọsiwaju
- Connect the black lead to COM and the red lead to VΩHz.
- Turn the rotary switch to the continuity symbol (speaker icon).
- Ensure the circuit is de-energized. Connect the test leads across the component. An audible tone indicates continuity.
5.5 Idanwo Diode
- Connect the black lead to COM and the red lead to VΩHz.
- Turn the rotary switch to the diode symbol.
- Ensure the circuit is de-energized. Connect the test leads across the diode. The display shows the forward voltage ju.
5.6 Measuring Capacitance (F)
- Connect the black lead to COM and the red lead to VΩHz.
- Turn the rotary switch to the capacitance symbol.
- Rí i dájú pé a ti tú capacitor náà sílẹ̀ kí o tó so àwọn èdìdì ìdánwò náà pọ̀.
5.7 Measuring Frequency (Hz) and Duty Cycle (%)
- Connect the black lead to COM and the red lead to VΩHz.
- Yi iyipada iyipo pada si Hz.
- Connect the test leads across the signal source. Press the '%' button to view ojuse ọmọ.
5.8 Measuring Temperature (°C/°F)
- Connect the K-type thermocouple (included) to the VΩHz and COM jacks, observing polarity.
- Turn the rotary switch to the temperature symbol.
- Place the thermocouple tip on the object to be measured.
5.9 Awọn iṣẹ pataki
- MIN MAX: Press to record minimum, maximum, and average readings over time.
- PEAK MIN MAX: Captures fast transients.
- REL Δ (Ipo ibatan): Subtracts the stored reading from subsequent readings, useful for nulling out test lead resistance.
- MU: Dii ti isiyi àpapọ kika.
6. Itọju
6.1 Ninu
Pa ọran naa pẹlu ipolowoamp Aṣọ àti ọṣẹ ìfọṣọ díẹ̀. Má ṣe lo àwọn ohun ìfọṣọ tàbí àwọn ohun tí ó ń yọ́ nǹkan. Rí i dájú pé ẹ̀rọ náà gbẹ kí o tó lò ó.
6.2 Batiri Rirọpo
Refer to Section 4.1 for battery replacement instructions. Replace batteries when the low battery indicator appears on the display.
6.3 Fiusi Rirọpo
WARNING: To prevent injury or damage to the multimeter, use only specified replacement fuses with the correct amperage, voltage, ki o si da gbigbi-wonsi.
The Fluke 28IIEX/ETL has two internal fuses:
- 10A Max Fused: For the 10A current input.
- 400mA Fused: For the mA/µA current input.
Fuse replacement should only be performed by qualified personnel. Consult the full service manual or contact Fluke customer support for detailed instructions.
7. Laasigbotitusita
Tí multimeter náà kò bá ṣiṣẹ́ bí a ṣe retí, a tún ṣe bẹ́ẹ̀view awọn iṣoro ti o wọpọ wọnyi:
- Ko si ifihan tabi ifihan ti ko lagbara: Ṣayẹwo awọn batiri ki o si ropo ti o ba wulo.
- Awọn kika ti ko tọ: Ensure test leads are correctly connected, the function and range are appropriate for the measurement, and the circuit is de-energized for resistance/continuity/diode tests.
- Wiwọn lọwọlọwọ ko ṣiṣẹ: Check the fuses for the respective current input (10A or 400mA). Replace if blown.
- Multimeter does not respond: Turn the unit off and then on again. If the issue persists, remove batteries for a few minutes and reinsert.
For persistent issues or complex problems, contact Fluke customer support.
8. Awọn pato
| Paramita | Sipesifikesonu |
|---|---|
| Maximum AC/DC Current Input | 10 A |
| Maximum AC/DC Voltage Input | 1000 V |
| A ti ri resistance to ga julọ | 50 MΩ |
| O pọju Igbohunsafẹfẹ | 199.99 kHz |
| O pọju Agbara | 9999 µF |
| Temperature Range (excluding probe) | -200 si +1090 °C / -328 si +1994 °F |
| Ojuse ọmọ Range | 0 si 99.9% |
| Ifihan | LCD with 20,000-count resolution, two-level backlight |
| Ibi ti ina elekitiriki ti nwa | Awọn batiri AA 4 (Alkali) |
| Awọn idiyele Ailewu | ATEX, NEC-500, IEXEx, IEC 61010, CAT III 1000V, CAT IV 600V, Pollution Degree 2 |
| Idaabobo Ingress | IP67 (Waterproof, Dust-proof, Drop-proof) |
| Iwọn | 2.85 lbs (1.29 kg) |
| Awọn iwọn (L x W x H) | 9.7 x 6.3 x 3.36 inches (24.6 x 16.0 x 8.5 cm) |
9. Atilẹyin ọja ati Support
Fluke Corporation products are designed for reliability and performance. For warranty information, technical support, or service, please visit the official Fluke website or contact your local Fluke representative.
Official Fluke Webojula: www.fluke.com