Pentair 239000034

Pentair 23900-0034 Covered Element 22-Inch Instruction Manual

Awoṣe: 239000034

1. Ọja Ipariview

The Pentair 23900-0034 Covered Element is a 22-inch replacement component designed for use in Pentair pool and spa filtration systems. This element is crucial for maintaining water clarity and hygiene by effectively filtering out debris and particles from the water.

It is engineered for reliability and energy efficiency, contributing to a cleaner and more enjoyable aquatic environment. This product is sold as a single covered element and requires no assembly prior to installation into the compatible filtration unit.

2. Alaye Aabo

  • Always disconnect power to the pump and filter system before performing any maintenance or installation.
  • Ensure the system is depressurized before opening the filter housing.
  • Wear appropriate personal protective equipment, such as gloves and eye protection, when handling pool chemicals or filter components.
  • Keep children and pets away from the pool equipment area during installation and maintenance.
  • Refer to your main filter system's manual for specific safety instructions and procedures.

WARNING: This product may expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

3. Eto ati fifi sori

The Pentair 23900-0034 Covered Element is designed for straightforward installation as a replacement part within compatible Pentair filter systems. No assembly of the element itself is required.

  1. Prepare the Filter System:
    • Turn off the pool pump and disconnect all power to the filter system.
    • Open the air relief valve on top of the filter to release any pressure.
    • Drain the filter tank according to your filter system's instructions.
  2. Access the Filter Elements:
    • Remove the filter tank lid or top section as per your filter system's manual. This usually involves unlatching clamps or unscrewing a collar.
    • Carefully lift out the existing filter elements. Note their orientation for proper reinstallation.
  3. Install the New Element:Pentair 23900-0034 Covered Element, side view

    Aworan 1: Apa view of the Pentair 23900-0034 Covered Element, showing its elongated, covered design.

    • Inspect the new Pentair 23900-0034 Covered Element for any damage.
    • Carefully slide the new element into its designated position within the filter manifold. Ensure it seats properly.
    • Repeat for all elements if replacing multiple.
  4. Reassemble and Start Up:Pentair 23900-0034 Covered Element, flat view

    Image 2: Flat view of the Pentair 23900-0034 Covered Element, illustrating its surface area and grid pattern.

    • Replace the filter tank lid and secure it according to the manufacturer's instructions.
    • Ti fáìlì ìtura afẹ́fẹ́ pa.
    • Turn on the pool pump. Once water begins to flow, slowly open the air relief valve until a steady stream of water (not air) emerges, then close it.
    • Check for leaks around the filter tank.

4. Isẹ

The Pentair 23900-0034 Covered Element operates passively within your pool or spa's cartridge filter system. Its primary function is to trap suspended particles as water passes through its filtration media.

  • Filtration Cycle: Water from the pool/spa is pumped into the filter tank, passes through the element, and clean water is returned to the pool/spa.
  • Abojuto titẹ: Monitor the pressure gauge on your filter system. A gradual increase in pressure indicates that the filter element is collecting debris and requires cleaning or replacement.
  • Iṣe Ti o dara julọ: For optimal filtration, ensure your pump is running for an adequate duration each day, typically 8-12 hours, depending on pool size and usage.

5. Itọju

Regular maintenance of the Pentair 23900-0034 Covered Element is essential for efficient filtration and extending the life of your filter system.

  1. Ìfọ̀mọ́ déédéé:
    • When the filter pressure rises 8-10 PSI above its clean starting pressure, it's time to clean the element.
    • Turn off the pump and depressurize the system as described in the "Setup and Installation" section.
    • Remove the element from the filter tank.
    • Hose off the element thoroughly with a garden hose, working from top to bottom, to remove loose debris.
  2. Deep Cleaning (Chemical Soak):
    • Periodically, or if hosing does not restore pressure adequately, soak the element in a specialized filter cleaning solution to remove oils, scale, and embedded debris. Follow the cleaner manufacturer's instructions carefully.
    • Rinse thoroughly after soaking.
  3. Ayewo ati Rirọpo:
    • Inspect the element for tears, cracks, or damage to the fabric or end caps during each cleaning.
    • A damaged element will not filter effectively and must be replaced immediately.
    • Filter elements typically last 1-3 years depending on usage, water chemistry, and maintenance. Replace the element when it no longer cleans effectively or shows signs of wear.

6. Laasigbotitusita

IsoroOwun to le FaOjutu
High Filter PressureClogged filter element.Clean or replace the filter element.
Omi Kekere / Àṣàlẹ̀ Tí Kò DáaClogged filter element, damaged element, or air in the system.Clean or replace element. Bleed air from the system. Check pump and skimmer for blockages.
Water Not ClearingDamaged filter element, improper water chemistry, or insufficient filtration time.Inspect and replace damaged element. Balance pool chemistry. Increase pump run time.
Leaks Around Filter TankImproperly sealed lid, damaged O-ring, or cracked tank.Ensure lid is properly secured. Inspect and replace O-ring if damaged. Consult a professional for tank damage.

If troubleshooting steps do not resolve the issue, contact a qualified pool technician or Pentair customer support.

7. Awọn pato

  • Nọmba awoṣe: 239000034
  • Iru ọja: Covered Element
  • Iwọn: 22-inch
  • Brand: Pentair
  • Awọn iwọn ọja: 19.25 x 0.75 x 19.25 inches
  • Ìwọ̀n Nkan: 1.8 iwon
  • Olupese: Pentair - Distribution

8. Atilẹyin ọja ati Support

For specific warranty information regarding your Pentair 23900-0034 Covered Element, please refer to the documentation provided with your complete Pentair filtration system or visit the official Pentair webojula.

For technical support, replacement parts, or further assistance, please contact Pentair customer service or an authorized Pentair dealer. Contact information can typically be found on the Pentair webaaye tabi ninu apoti ọja rẹ.

Oṣiṣẹ Pentair Webojula: www.pentair.com

Awọn iwe aṣẹ ti o jọmọ - 239000034

Ṣaajuview Àlẹ̀mọ́ Pentair Clean and Clear Plus Cartridge: Ìfisílẹ̀ àti Ìtọ́sọ́nà Olùlò
Ìtọ́sọ́nà tó péye nípa fífi sori ẹrọ, ìṣiṣẹ́, àti ìtọ́jú fún Pentair Clean and Clear Plus Cartridge Filter. Ó ní àwọn ìtọ́ni ààbò, ìṣòro, dátà ìmọ̀-ẹ̀rọ, àti ìwífún nípa àwọn ẹ̀yà ara tí a fi rọ́pò.
Ṣaajuview Pentair Replacement Parts Price List 2021
Official Pentair 2021 Replacement Parts Price List, detailing part numbers, descriptions, and prices in USD and CAD for a wide range of pool and spa equipment.
Ṣaajuview Pentair T40-FN Automatic Pool Filler for Vanishing Edge Pools - Installation Guide
Learn about the Pentair T40-FN Automatic Pool Filler, designed for vanishing edge pools. This guide provides installation details and safety warnings for ensuring proper integration with catch basins and rebar.
Ṣaajuview Pentair Clean and Clear Plus Cartridge Filter Installation and User's Guide
Comprehensive installation, operation, and maintenance guide for the Pentair Clean and Clear Plus Cartridge Filter, including safety instructions, troubleshooting, and technical specifications.
Ṣaajuview Pentair Clean & Clear RP Filters Replacement Parts List
Detailed replacement parts list for Pentair Clean & Clear RP Filters, including part numbers and descriptions for components such as lids, O-rings, cartridges, unions, and relief valves. Features an exploded view apejuwe aworan atọka.
Ṣaajuview How to Safely Service Pentair Clean & Clear Plus Cartridge Filter in Four Key Steps
A guide to safely servicing the Pentair Clean & Clear Plus Cartridge Filter, outlining four essential steps for proper maintenance and operation to prevent injury and damage. Includes critical safety warnings regarding high pressure systems.