1. Ifihan
This manual provides essential information for the safe and effective operation, installation, and maintenance of the FLUX F 457 EL Commutator Motor. This motor is designed for professional use with FLUX barrel and container pumps, offering 800 watts of power, variable speed control, and a no-volt release mechanism for enhanced safety. Please read all instructions carefully before use.
2. Alaye Aabo
AlAIgBA Ofin: This item, component, package, or system is intended for professional use only, by persons knowledgeable of how to determine if it is chemically compatible with the liquid(s) to be pumped, the safe installation, use, and maintenance of pressure-generating and pressure-containing devices, and the safe installation, use, and maintenance of electrically, pneumatically, and hydraulically powered equipment.
- Always ensure the motor is disconnected from the power supply before performing any maintenance or installation procedures.
- Verify chemical compatibility between the motor components and the pumped media.
- Operate the motor only in well-ventilated areas.
- The no-volt release feature prevents accidental startup after a power interruption, enhancing user safety. Do not bypass this safety mechanism.
3. Awọn ẹya Ọja
- Ijade agbara: 800 watts, providing robust performance for various pumping tasks.
- Voltage: 120 Volts, 60 Hz.
- Iwọn Idaabobo: IP 24 splash-proof, suitable for industrial environments.
- Iyara Ayipada: Electronic speed setting for precise control over pumping volume.
- No-Volt Release: Integrated safety feature to prevent uncontrolled restarts after power loss.
- Eto Itutu: Excellent air cooling for extended service life and low noise levels.
- Ibamu: Designed to work seamlessly with all FLUX barrel and container pumps.
4. Eto
- Ṣii silẹ: Carefully remove the motor from its packaging and inspect for any signs of damage.
- Iṣagbesori: Attach the F 457 EL motor securely to the appropriate FLUX barrel or container pump. Ensure a firm connection to prevent dislodgement during operation.
- Asopọ agbara: Connect the motor's power supply cable (16' long, 2-pole plug) to a compatible 120V, 60Hz power outlet. Ensure the outlet is properly grounded.
- Ṣayẹwo Isẹ-tẹlẹ: Before starting, confirm all connections are secure and the pump is correctly positioned in the liquid to be transferred.
5. Isẹ
- Bibẹrẹ Motor: Press the green 'ON' switch located on the handle. The motor should start immediately.
- Iyara Ṣatunṣe: Use the electronic speed setting dial (if applicable) to control the motor's RPM and thus the pumping volume. Turn the dial clockwise to increase speed and counter-clockwise to decrease it.
- Dídáwọ́ Mọ́tò náà dúró: Press the red 'OFF' switch or release the 'ON' switch (if it's a momentary switch).
- No-Volt Release: In the event of a power interruption, the motor will automatically shut off and will not restart until the 'ON' switch is manually pressed again after power is restored. This is a critical safety feature.
6. Itọju
- Ninu igbagbogbo: Keep the motor housing clean and free from dust and debris to ensure optimal air cooling. Use a dry cloth for cleaning.
- Ayewo: Periodically inspect the power cable for any signs of damage, fraying, or wear. Replace immediately if damage is found.
- Afẹfẹ: Ensure the motor's ventilation openings are not obstructed during operation.
- Iṣẹ Ọjọgbọn: For internal maintenance or repairs, contact authorized FLUX service personnel. Do not attempt to open the motor housing yourself.
7. Laasigbotitusita
- Mọto Ko Bẹrẹ:
- Ṣayẹwo ipese agbara ati awọn asopọ.
- Ensure the 'ON' switch is fully engaged.
- Verify that the no-volt release has been reset by pressing the 'ON' switch after a power interruption.
- Reduced Pumping Performance:
- Check the speed setting; adjust if necessary.
- Inspect the pump for blockages or wear (refer to pump manual).
- Ariwo dani tabi gbigbọn:
- Duro mọto naa lẹsẹkẹsẹ.
- Inspect for loose connections or foreign objects.
- If the issue persists, contact FLUX service.
8. Imọ ni pato
| Sipesifikesonu | Iye |
|---|---|
| Nọmba awoṣe | F 457 EL |
| Ijade agbara | 800 Wattis |
| Awọn ọna Voltage | 120 Volts |
| Igbohunsafẹfẹ | 60 Hz |
| International Idaabobo Rating | IP24 (Imudaniloju Asesejade) |
| Awọn iwọn Ọja (L x W x H) | 5.5 x 8.5 x 8.88 inches |
| Iwọn Nkan | 8.82 iwon |
| Asopọmọra Iru | Pulọọgi sinu |
| Olupese | FLUX Pumps Corporation |
9. Performance ekoro
The following charts illustrate the performance characteristics of the FLUX F 457 EL motor when paired with different pump tube sets. These curves show the relationship between head (H) and flow rate (Q) for various configurations.

Image: Performance curve for FLUX F 457 EL motor with PP/PVDF barrel pump tube sets. The graph displays head (H in mWS) versus flow rate (Q in US GPM, IMP GPM, and L/min) for various 'Z' values (e.g., 43 Z, 35 Z, 33 Z, 38, 36, 34).

Image: Performance curve for FLUX F 457 EL motor with Stainless Steel (S), Aluminum (AL), and Hastelloy C (HC) barrel pump tube sets. The graph displays head (H in mWS) versus flow rate (Q in US GPM, IMP GPM, and L/min) for various 'Z' values (e.g., 45 Z, 37 Z, 38, 34).
10. Ibamu
The FLUX F 457 EL Commutator Motor is engineered for optimal performance and compatibility with all FLUX barrel and container pumps. Ensure that the specific pump model you intend to use is compatible with the F 457 EL motor for safe and efficient operation.