Cisco UCSC-C240-M3S-CH2

Cisco UCS C240 M3 High-Density Rack-Mount Server Instruction Manual

Model: UCSC-C240-M3S-CH2

1. Ifihan

This manual provides essential instructions for the installation, operation, and maintenance of the Cisco UCS C240 M3 High-Density Rack-Mount Server. The Cisco UCS C240 M3 is a 2-socket, 2U rack server designed for a broad range of workloads, offering high performance and expandability. Please read this manual thoroughly before proceeding with any operations to ensure proper handling and to prevent damage to the equipment or injury to personnel.

2. Alaye Aabo

Observe the following safety precautions to minimize the risk of injury and to prevent damage to the server:

3. Package Awọn akoonu

Verify that all components are present and undamaged upon unpacking. The standard package for the Cisco UCS C240 M3 server typically includes:

If any items are missing or damaged, contact your Cisco representative or reseller immediately.

4. Ti ara Loriview

This section provides a visual guide to the external components of the Cisco UCS C240 M3 server.

4.1 Igbimọ iwaju

Iwaju view of Cisco UCS C240 M3 server with 24 small form factor drive bays

Nọmba 4.1: Iwaju view of the Cisco UCS C240 M3 server. This image displays the front panel of the server, featuring 24 small form factor (SFF) hot-swappable drive bays, status LEDs, and control buttons on the left and right ears.

The front panel provides access to the hot-swappable drive bays, system status indicators, and control buttons. The C240 M3 supports up to 24 SFF 2.5-inch drives.

4.2 ru Panel

Ẹyìn view of Cisco UCS C240 M3 server showing power supplies, network ports, and expansion slots

Nọmba 4.2: Ẹyìn view of the Cisco UCS C240 M3 server. This image illustrates the rear panel, including redundant hot-swappable power supplies, multiple Gigabit Ethernet ports, USB ports, a VGA port, and PCIe expansion slots.

The rear panel houses the power supply units, network interfaces, and various I/O ports. It typically includes:

4.3 Top/Side View

Angled top-front view of Cisco UCS C240 M3 server

Nọmba 4.3: Angled top-front view of the Cisco UCS C240 M3 server. This image provides a perspective of the server's chassis, highlighting its 2U rack-mountable form factor and overall design.

Eyi view illustrates the overall 2U rack-mountable form factor of the server, designed for high-density environments.

5. Eto

Follow these steps to properly set up your Cisco UCS C240 M3 server.

5.1 agbeko fifi sori

  1. Ṣetan Rack: Ensure the rack is stable and has adequate space for a 2U server.
  2. Fi Ohun elo Reluwe sori ẹrọ: Attach the provided rail kit to the rack posts according to the instructions included with the rail kit.
  3. Mount the Server: Carefully slide the server onto the installed rails until it clicks into place. Secure the server to the rack using the provided screws.

5.2 Nsopọ Peripherals

5.3 Ibẹrẹ Agbara Lori

  1. Rii daju pe gbogbo awọn asopọ wa ni aabo.
  2. Tẹ bọtini agbara ni iwaju nronu.
  3. Observe the system status LEDs for normal operation.
  4. Access the Cisco Integrated Management Controller (IMC) via a web browser using the server's management IP address for further configuration. Refer to the Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide for detailed instructions.

6. Operating the Server

This section covers basic operational procedures for the Cisco UCS C240 M3 server.

6.1 Power On/Off Procedures

6.2 Accessing Cisco IMC

The Cisco Integrated Management Controller (IMC) provides a web-based interface for server management. To access it:

  1. Ensure the server's management port is connected to the network.
  2. Obtain the IP address assigned to the IMC (either through DHCP or manual configuration during initial setup).
  3. Ṣii a web browser and enter the IMC's IP address.
  4. Wọle pẹlu awọn iwe-ẹri rẹ.

6.3 Fifi sori ẹrọ eto

Operating system installation can be performed via the Cisco IMC's KVM console, virtual media, or by booting from a physical optical drive or USB device connected to the server. Consult your chosen operating system's installation guide for specific steps.

7. Itọju

Regular maintenance ensures optimal performance and longevity of your server.

7.1 Gbona-Swappable irinše

The Cisco UCS C240 M3 features hot-swappable components, allowing replacement without powering down the server. These include:

Refer to the Cisco UCS C240 M3 Server Installation and Service Guide for detailed instructions on replacing specific components.

7.2 Ninu

Periodically inspect the server for dust accumulation, especially around air vents and fan inlets/outlets. Use compressed air to gently clean dust from internal components and external surfaces. Ensure the server is powered off and disconnected from power before cleaning internal components.

7.3 famuwia imudojuiwọn

Nigbagbogbo ṣayẹwo Cisco support website for firmware updates for the server, RAID controller, and other components. Firmware updates can provide performance enhancements, bug fixes, and security improvements. Follow Cisco's recommended procedures for applying firmware updates.

8. Laasigbotitusita

This section provides guidance for resolving common issues.

8.1 LED Atọka

The server's front panel and individual components (e.g., power supplies, drives) feature LED indicators that provide status information. Consult the Cisco UCS C240 M3 Server Installation and Service Guide for a comprehensive list of LED patterns and their meanings.

8.2 Wọpọ Oran ati Solusan

8.3 Olubasọrọ Support

If you encounter issues that cannot be resolved using this guide, contact Cisco Technical Support. Have your server's serial number and a description of the problem ready.

9. Awọn pato

Key technical specifications for the Cisco UCS C240 M3 High-Density Rack-Mount Server:

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeUCSC-C240-M3S-CH2
Fọọmù ifosiweweRack-mountable, 2U
Atilẹyin ilana2-way (Dual Processor Capable)
Memory (Base)0 MB (Configurable)
Ibi InterfaceSATA/SAS, Hot-swap 2.5" bays
Adarí eya aworanG200e
Adarí NẹtiwọọkiGigabit LAN
AtẹleNone (External connection via VGA)
Ọja Mefa39.7 x 24.1 x 10 inches
Iwọn Nkan54.7 iwon
Awọn batiriỌja Specific batiri beere.
Ọjọ Akọkọ WaOṣu kọkanla ọjọ 1, ọdun 2013

10. Atilẹyin ọja ati Support

For detailed information regarding the product warranty, service agreements, and technical support options, please refer to the official Cisco website or contact your authorized Cisco reseller. Warranty terms and conditions may vary based on region and purchase agreement.

Awọn orisun Atilẹyin Cisco:

Awọn iwe aṣẹ ti o jọmọ - UCSC-C240-M3S-CH2

Ṣaajuview Cisco UCS C240 M6 LFF Rack Server Spec Sheet
Detailed specifications and configuration guide for the Cisco UCS C240 M6 LFF Rack Server, covering its capabilities, features, technical details, and spare parts.
Ṣaajuview Cisco UCS C-jara Integration pẹlu Sisiko UCS Manager: A okeerẹ Itọsọna
Itọsọna yii n pese alaye alaye ati awọn ilana fun sisọpọ awọn olupin Sisiko UCS C-Series Rack-Mount Servers pẹlu Sisiko UCS Manager, ibora awọn ipo asopọ, ibaramu ohun elo, topology nẹtiwọki, awọn kaadi ohun ti nmu badọgba, ati awọn atunto oluṣakoso RAID/ibi ipamọ.
Ṣaajuview Cisco UCS famuwia Igbesoke Awọn Itọsọna ati Prerequisites
Itọsọna okeerẹ ti n ṣe alaye awọn iṣe ti o dara julọ, awọn ohun pataki, ati awọn ilana fun imudara famuwia lori awọn ọna ṣiṣe Sisiko UCS, pẹlu awọn asopọ aṣọ, awọn olupin, ati awọn oluyipada.
Ṣaajuview Cisco UCS C220 M5 Rack Server Spec Sheet
Detailed specifications and configuration guide for the Cisco UCS C220 M5 Rack Server (Small Form Factor Disk Drive Model), covering its features, components, and setup.
Ṣaajuview Cisco UCS C-シリーズ ソフトウェア リリースノート 3.0(4)
Cisco UCS C-シリーズソフトウェア リリース 3.0(4) tabi 3.0 (4)サーバの最新機能、システム要件、既知の問題、および互換性情報について解説します。
Ṣaajuview Cisco UCS C220 M7 Server sori ati Itọsọna Service
Comprehensive guide for installing, configuring, and servicing the Cisco UCS C220 M7 server, covering hardware setup, component replacement, and system configuration for enterprise environments.