1. Ifihan
This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.
The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.
2. Alaye Aabo
- Always operate the device within its specified environmental conditions.
- Ma ṣe fi ẹrọ naa han si awọn iwọn otutu to gaju, imọlẹ orun taara, tabi ọriniinitutu giga.
- Yago fun sisọ silẹ tabi tẹriba ẹrọ si awọn ipa to lagbara.
- Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
- Ma ṣe gbiyanju lati ṣii tabi tun ẹrọ naa funrararẹ. Tọkasi gbogbo iṣẹ si oṣiṣẹ oṣiṣẹ.
- Use only compatible pH electrodes and accessories with this converter.
- Dispose of the device and any associated components in accordance with local environmental regulations.
3. Package Awọn akoonu
Jọ̀wọ́ ṣàyẹ̀wò ohun tó wà nínú àpótí náà nígbà tí o bá gbà á. Tí àwọn nǹkan kan bá sọnù tàbí tí wọ́n bá bàjẹ́, kàn sí olùpèsè rẹ lẹ́sẹ̀kẹsẹ̀.
- Greisinger GPHU 014 MP/BNC pH Measurement Converter
- Ilana Afowoyi (iwe yii)
- Mounting accessories (if applicable, check packaging)
Note: A pH electrode is not included with this converter and must be purchased separately.
4. Ọja Ipariview
The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.
Nọmba 1: Iwaju view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.
Nọmba 2: Apa view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".
Awọn eroja pataki:
- Ifihan Digital: Shows pH value, temperature, and status indicators.
- ṢE ÀTẸ̀ṢẸ̀ Bọ́tìnì (1): A lo lati tẹ ati jẹrisi awọn eto.
- Down Button (2): Used to navigate menus and decrease values.
- Up Button (3): Used to navigate menus and increase values.
- Asopọmọra BNC: For connecting a compatible pH electrode.
- Iṣagbewọle agbara: (Location not visible in images, refer to device for exact position)
5. Eto
5.1. Iṣagbesori
The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.
5.2. Connecting the pH Electrode
- Ensure the converter is powered off.
- Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
- Ensure the connection is secure but do not overtighten.
5.3. Asopọ agbara
Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.
5.4. Iṣatunṣe ibẹrẹ
Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.
- Agbara lori ẹrọ naa.
- Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
- Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
- Rinse the electrode thoroughly with distilled water between buffer solutions.
- Confirm calibration settings.
6. Ṣiṣẹ
6.1. Gbigbe Iwọn kan
- Ensure the pH electrode is properly connected and calibrated.
- Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
- Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
- Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.
6.2. Lilọ kiri Akojọ aṣyn
The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.
- SET (1): Enter/Exit menu, confirm selection.
- ▼ (2): Scroll down, decrease value.
- ▲ (3): Scroll up, increase value.
Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.
7. Itọju
7.1. Cleaning the Converter
Wipe the exterior of the converter with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
7.2. Itoju pH Electrode
Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:
- Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
- Rinse the electrode with distilled or deionized water after each measurement.
- Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
- Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.
7.3. Ibi ipamọ
When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.
8. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| No display/Device not powering on | No power, faulty power supply, incorrect connection. | Check power cable and source. Ensure correct voltage. |
| Unstable or inaccurate pH readings | Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. | Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings. |
| "Error" message on display | Electrode fault, out of range measurement, internal device error. | Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent. |
| O lọra esi akoko | Aged or dirty electrode, low sample iwọn otutu. | Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode. |
If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.
9. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Olupese | GREISINGER |
| Nọmba Awoṣe Nkan | 602331 |
| Awọn iwọn Ọja (L x W x H) | 5.5 x 8.2 x 8 cm; 9.07 giramu |
| ASIN | B00ICKLET6 |
| Opoiye ti awọn ohun kan | 1 |
| Battery(ies) included | Rara |
| Battery(ies) required | Rara |
| Ọjọ́ tí a kọ́kọ́ rí lórí Amazon.com.be | Oṣu Kẹjọ Ọjọ 12, Ọdun 2022 |
| Olùpèsè dáwọ́ dúró | Rara |
| Apoju awọn ẹya wiwa | Alaye ko si lori apoju awọn ẹya ara |
10. Atilẹyin ọja ati Support
Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger webojula.
For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger webojula.