BFT ICARO

Ìwé Ìtọ́ni fún Olùṣiṣẹ́ BFT Icaro Fast Commercial Duty Slide Gate

Model: ICARO | Brand: BFT

1. Ifihan

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the BFT Icaro Fast Commercial Duty Slide Gate Operator. Please read this manual thoroughly before beginning any procedures to ensure proper functionality and safety.

The BFT Icaro Fast is designed for commercial slide gates, offering robust performance and reliability. It is equipped with advanced features for secure and convenient gate automation.

2. Alaye Aabo

WARNING: Failure to follow these safety instructions could result in serious injury or death, and damage to property.

  • Fifi sori ẹrọ ati itọju gbọdọ jẹ nipasẹ oṣiṣẹ ti o peye nikan.
  • Ensure all power is disconnected before performing any service or maintenance.
  • Keep hands, feet, and clothing clear of the gate and operator during operation.
  • Do not allow children to play near the gate or operate the controls.
  • Install safety devices such as photocells and safety edges as required by local regulations.
  • The gate must be properly balanced and in good working condition before operator installation.

3. Eto ati fifi sori

This section outlines the steps for installing the BFT Icaro Fast slide gate operator. Refer to the detailed wiring diagrams provided in the separate installation guide for electrical connections.

3.1 Unpacking ati ayewo

Carefully unpack all components and inspect for any shipping damage. Report any damage to your supplier immediately.

3.2 Fifi sori ẹrọ oniṣẹ naa

  1. Choose a stable, level mounting surface adjacent to the gate.
  2. Securely fasten the operator base to the concrete pad or mounting plate using appropriate hardware.
  3. Ensure the operator is correctly aligned with the gate's movement path.

3.3 Fifi agbeko

The gate rack is essential for the operator's movement. Rack is available in nylon or metal material. Each piece of rack is typically 3.3 ft. long. To determine the required number of rack pieces, divide your total gate length by 3.3.

  1. Attach the rack securely to the gate, ensuring it is level and parallel to the operator's pinion gear.
  2. Maintain a small clearance (approximately 1-2mm) between the rack and the pinion to allow for smooth operation and thermal expansion.

3.4 Electrical Awọn isopọ

All electrical connections must comply with local electrical codes and standards. The power supply is 120V +-10%, 60Hz single-phase. Connect the main power, safety devices (photocells, safety edges), and control accessories to the LEO D control panel (incorporated) as per the wiring diagram.

3.5 Limit Switch Adjustment

The Icaro Fast uses electromechanical limit switches. Adjust these switches to define the gate's fully open and fully closed positions. Refer to the control panel manual for precise adjustment procedures.

BFT Icaro Fast Commercial Duty Slide Gate Operator

Figure 1: BFT Icaro Fast Commercial Duty Slide Gate Operator. This image shows the main unit of the gate operator, a grey rectangular housing with a blue manual release knob on the lower front.

4. Awọn ilana Iṣiṣẹ

4.1 Ipilẹ isẹ

The gate can be operated using the provided BFT Mitto remotes or other compatible control devices. Pressing the designated button on the remote will initiate the gate's movement (open or close). A second press will typically stop the gate, and a third press will reverse its direction.

4.2 Isakoṣo latọna jijin siseto

Refer to the BFT Mitto remote control manual for detailed instructions on programming additional remotes or reprogramming existing ones. This process typically involves accessing the control panel's programming mode.

4.3 Afowoyi Tu

In case of power failure or malfunction, the gate can be operated manually. Locate the manual release mechanism (typically a key-operated lever or knob, as seen in Figure 1) on the operator. Insert the key and turn it to disengage the motor, allowing the gate to be moved by hand. Remember to re-engage the motor after manual operation.

5. Itọju

Regular maintenance ensures the longevity and reliable operation of your BFT Icaro Fast gate operator. Perform these checks periodically:

  • Oṣooṣu: Inspect the gate for smooth movement, ensuring no obstructions or excessive friction. Check the rack for wear and proper engagement with the pinion.
  • Ni idamẹrin: Clean the operator housing and remove any debris. Check all electrical connections for tightness and signs of corrosion. Test all safety devices (photocells, safety edges) for proper function.
  • Ọdọọdún: Have a qualified technician inspect the motor, gearbox, and control panel. Lubricate moving parts as recommended by BFT (refer to the full technical manual for specific lubrication points and types).

CAUTION: Always disconnect power before performing any maintenance or cleaning.

6. Laasigbotitusita

This section provides solutions for common issues. For problems not listed here, contact technical support.

IsoroOwun to le FaOjutu
Ẹnubode ko gbe.No power; remote battery dead; safety device activated; motor disengaged.Check power supply; replace remote battery; clear safety device path; re-engage motor.
Ẹnu-ọna duro lairotẹlẹ.Obstruction detected; safety device activated; limit switch issue.Remove obstruction; check safety devices; inspect and adjust limit switches.
Isakoṣo latọna jijin ko ṣiṣẹ.Dead battery; out of range; not programmed.Replace battery; move closer to receiver; reprogram remote.

7. Awọn pato

Technical specifications for the BFT Icaro Fast Commercial Duty Slide Gate Operator:

  • Max Gate Weight: 2200 lbs
  • Gigun Ẹnu-ọna Ti o pọju: 65 ẹsẹ
  • Output Revolutions: 37 fun iseju
  • Pinion Pitch: 4 mm (eyin 25)
  • Ibi ti ina elekitiriki ti nwa: 120V +-10%, 60Hz single-phase
  • Ibi iwaju alabujuto: LEO D (incorporated)
  • Type of Limit Switch: Electromechanical
  • Awọn ipo Ayika: 5°F si 140°F (-15°C si 60°C)
  • Idaabobo Gbona: Ti ṣepọ
  • Leaf Speed: 12 m/ min
  • Nọmba awoṣe: BFT-ICARO-GATE-OPENER
  • ASIN: B00ICUG50E

8. Atilẹyin ọja ati Support

This product is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official BFT website for detailed warranty terms and conditions. For technical support, spare parts, or service inquiries, please contact your authorized BFT dealer or distributor.

For further assistance, please have your model number (ICARO) and ASIN (B00ICUG50E) ready when contacting support.

Awọn iwe aṣẹ ti o jọmọ - ICARO

Ṣaajuview BFT ICARO UL Actuator fun fifi sori Gates Sisun Rack ati Itọsọna olumulo
Fifi sori okeerẹ ati itọsọna olumulo fun BFT ICARO UL actuator, ti a ṣe apẹrẹ fun awọn ẹnu-ọna sisun agbeko. Ibojuto ilana gbogbogbo, awọn iṣọra ailewu, itusilẹ afọwọṣe, awọn pato imọ-ẹrọ, awọn igbesẹ fifi sori ẹrọ, wirin, ati laasigbotitusita.
Ṣaajuview BFT Mitto 2M/4M Awọn ilana Ifaminsi Latọna jijin: Itọsọna okeerẹ kan
Kọ ẹkọ bii o ṣe le ṣe eto BFT Mitto 2M rẹ ati awọn iṣakoso latọna jijin 4M fun gareji ati awọn ṣiṣi ẹnu-ọna. Itọsọna yii ni wiwa ifaminsi fun awọn olugba pẹlu ati laisi awọn iboju oni-nọmba, pẹlu awọn ikilọ ailewu pataki.
Ṣaajuview Ilana fifi sori ẹrọ ati Uso BFT GIOTTO 30-60 S BT / GIOTTO 30-60 BT
Guida completa fun l'fifi sori ẹrọ ati l'utilizzo delle barriere automatiche BFT GIOTTO 30-60 S BT e GIOTTO 30-60 BT. Ni pato tecniche, configurazione ati manutenzione.
Ṣaajuview BFT VIRGO Swing Gate Automation Fifi sori Afowoyi
Fifi sori ẹrọ okeerẹ ati itọsọna olumulo fun eto adaṣe ẹnu-ọna swing BFT VIRGO, aabo ibora, awọn alaye imọ-ẹrọ, awọn ilana fifi sori ẹrọ, siseto, ati itọju.
Ṣaajuview BFT MITTO 2B Awọn ilana Ifaminsi Latọna | Retiro Remotes
Itọsọna igbese-nipasẹ-igbesẹ fun ifaminsi BFT MITTO 2B latọna jijin fun awọn ṣiṣi ẹnu-ọna, ibora ti o wa latọna jijin ati awọn ọna iboju LCD olugba. Pẹlu awọn imọran laasigbotitusita.
Ṣaajuview BFT GIUNO ULTRA BT A20 / GIUNO ULTRA BT A50 Piston Automation Installation Manual
Comprehensive installation manual for the BFT GIUNO ULTRA BT A20 and GIUNO ULTRA BT A50 hydraulic piston automations for swing gates. Covers technical specifications, mounting, wiring, adjustments, and safety precautions.