1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo 4CPM/80C electric centrifugal pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.
2. Awọn ilana aabo
Always observe the following safety precautions to prevent personal injury or damage to the pump.
- Aabo Itanna: Ensure the pump is connected to a properly grounded electrical supply. Disconnect power before performing any maintenance or installation. Do not operate the pump with damaged cables or plugs.
- Aabo omi: This pump is designed for clean water applications. Do not use it for flammable, corrosive, or explosive liquids.
- Fifi sori: Install the pump in a dry, well-ventilated area, protected from direct weather exposure. Ensure stable mounting to prevent vibration.
- Isẹ: Never run the pump dry. Ensure the pump is adequately primed before starting. Keep hands and loose clothing away from moving parts.
- Itọju: Only qualified personnel should perform repairs. Use genuine Pedrollo replacement parts.
3. Àpèjúwe Ọjà àti Àwọn Ohun Èlò Rẹ̀
The Pedrollo 4CPM/80C is a multi-stage electric centrifugal pump designed for domestic, agricultural, and industrial applications requiring high flow rates and moderate head. It is suitable for pumping clean water and non-aggressive liquids.

An image showing the Pedrollo 4CPM/80C electric centrifugal pump. The pump is blue, with a motor section featuring cooling fins and a pump body with inlet and outlet ports. A red cap is visible on the pump body, likely for priming or draining.
Awọn ẹya pataki:
- Flow rate up to 160 L/min (9.6 m³/h)
- Head up to 56 meters
- Robust construction for reliable performance
- Apẹrẹ fun lemọlemọfún ojuse
4. Eto ati fifi sori
4.1. Ipo
Choose a location that is dry, frost-free, and well-ventilated. The pump should be installed as close as possible to the water source to minimize suction lift. Ensure adequate space around the pump for ventilation and maintenance.
4.2. Iṣagbesori
Securely mount the pump to a solid, level surface using appropriate bolts to prevent vibration and movement during operation.
4.3. Plumbing Awọn isopọ
- Use pipes of adequate diameter to minimize friction losses.
- Install a foot valve with a strainer at the end of the suction line to prevent debris entry and maintain prime.
- Ensure all connections are airtight to prevent air leaks, which can cause loss of prime.
- Install a check valve on the discharge line if the pump is operating against a significant head or if backflow is a concern.
4.4. Asopọ Itanna
The pump operates on 230 Volts. Ensure your electrical supply matches this requirement. Connect the pump to a dedicated circuit protected by a residual current device (RCD) and an appropriately sized circuit breaker. All electrical wiring must comply with local codes and regulations.
4.5. Ṣíṣe àtúnṣe Pọ́ọ̀pù
Before the first start-up, or if the pump has run dry, it must be primed. Remove the priming plug (often a red cap or brass plug) on the top of the pump casing and fill the pump body completely with clean water until it overflows. Replace the plug securely.
5. Awọn ilana Iṣiṣẹ
5.1. Ibẹrẹ ibẹrẹ
- Ensure the pump is properly primed.
- Open any necessary valves on the suction and discharge lines.
- Yipada lori ipese agbara si fifa soke.
- The pump should start and begin pumping water. Monitor for unusual noises or vibrations.
5.2. Isẹ deede
Allow the pump to run continuously within its specified operating range. Avoid frequent on/off cycling, which can reduce motor life. Regularly check for leaks and ensure adequate water supply.
5.3. Títìpa
To stop the pump, simply switch off the power supply. If the pump will be out of use for an extended period, especially in freezing conditions, drain the pump completely to prevent damage.
6. Itọju
Itọju deedee n ṣe idaniloju pe fifa rẹ yoo pẹ to ati pe yoo ṣiṣẹ daradara.
- Awọn iṣayẹwo deede: Periodically inspect the pump for leaks, unusual noises, or excessive vibration. Check electrical connections for signs of wear or corrosion.
- Ninu: Keep the pump exterior clean and free of dust and debris to ensure proper motor cooling.
- Igba otutu: In areas subject to freezing temperatures, the pump must be completely drained to prevent ice damage. Disconnect power, open drain plugs, and remove the priming plug to allow all water to escape. Store the pump in a warm, dry place if possible.
- Impeller/Seal Inspection: If performance degrades, the impeller or mechanical seal may require inspection or replacement. This should be performed by a qualified technician.
7. Laasigbotitusita
Apá yìí ṣàlàyé àwọn ọ̀ràn tó wọ́pọ̀ àti àwọn ojútùú tó lè wà níbẹ̀.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | No power; Motor overload; Seized impeller | Check power supply, circuit breaker, RCD; Allow motor to cool and reset overload; Contact technician for seized impeller. |
| Pọ́ọ̀pù ń ṣiṣẹ́ ṣùgbọ́n kò sí omi tàbí ìṣàn omi díẹ̀ | Loss of prime; Air leak in suction line; Clogged foot valve/strainer; Worn impeller | Re-prime the pump; Check all suction connections for leaks; Clean foot valve/strainer; Contact technician for worn impeller. |
| Ariwo pupọ tabi gbigbọn | Cavitation (air in water); Loose mounting; Bearing wear; Debris in pump | Check for air leaks, ensure adequate water supply; Tighten mounting bolts; Contact technician for bearing wear or debris removal. |
| Pump jo | Loose connections; Damaged mechanical seal | Tighten pipe connections; Contact technician for seal replacement. |
Ti iṣoro naa ba wa lẹhin igbiyanju awọn ojutu wọnyi, jọwọ kan si onimọ-ẹrọ iṣẹ ti o peye.
8. Awọn pato
| Iwa | Iye |
|---|---|
| Olupese | PEDROLLO |
| Nọmba awoṣe | PSF 43CPN081A1 (4CPM/80C) |
| Orisun agbara | Okun Itanna |
| Voltage | 230 Volts |
| Oṣuwọn Sisan ti o pọju | 160 L/min (9.6 m³/h) |
| Max Ori | 56 mita |
| ASIN | B00ITSNWBY |
9. Atilẹyin ọja ati Support
For information regarding warranty coverage, technical support, or spare parts, please refer to the documentation provided with your purchase or contact Pedrollo customer service directly. Specific warranty details are not provided in this manual.
Ibi iwifunni: Please refer to the official Pedrollo website or your local distributor for contact details.