Ọrọ Iṣaaju
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Astral Pool Victoria Plus Pool Pump. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
Key features of the Astral Pool Victoria Plus Pool Pump include:
- Simple and sturdy design with an easy-to-use pre-filter nut.
- Silent operation, enhanced by integrated rubber feet.
- Motor protection class IP-55, ensuring durability and safety.
- Equipped with a large capacity pre-filter basket for efficient debris collection.

Figure 1: Astral Pool Victoria Plus Pool Pump. This image displays the complete pool pump unit, highlighting its compact design, the motor housing on the left, and the pre-filter basket with its transparent lid on the right. The inlet and outlet connections are also visible.
Eto ati fifi sori
Proper installation is crucial for the pump's performance and safety. It is recommended that installation be performed by a qualified professional.
1. Aye Yiyan
- Install the pump in a dry, well-ventilated area, protected from direct sunlight and rain.
- Ensure the location allows for easy access for maintenance and servicing.
- The pump should be installed as close to the pool as possible to minimize friction loss in the plumbing.
- Ensure the base is level and stable to prevent vibration and noise. The integrated rubber feet help with silent operation.
2. Plumbing Awọn isopọ
- Connect the suction line from the pool to the inlet port of the pump (typically the side port).
- Connect the discharge line to the outlet port (typically the top port) leading to the filter system.
- Use appropriate PVC fittings and solvent cement for secure, leak-free connections.
- Ensure all connections are tight but do not overtighten plastic fittings.
3. Asopọ Itanna
- Daju pe awọn ipese agbara voltage matches the pump's requirements (230 Volts).
- All electrical wiring must comply with local electrical codes and regulations.
- Awọn fifa gbọdọ wa ni ilẹ daradara.
- Install a suitable circuit breaker or fuse for motor protection. The motor protection class is IP-55.
Awọn ilana Iṣiṣẹ
Follow these steps for safe and effective operation of your pool pump.
1. Ṣíṣe àtúnṣe Pọ́ọ̀pù
- Ensure the pool water level is adequate.
- Open all suction and return valves in the plumbing system.
- Remove the pre-filter basket lid by unscrewing the pre-filter nut.
- Fill the pre-filter basket with water until it overflows.
- Replace the pre-filter basket lid and tighten the nut securely to prevent air leaks.
- Turn on the pump. The pump should prime within a few minutes. If not, turn it off, re-prime, and check for air leaks.
2. Isẹ deede
- Once primed, the pump will circulate water through the filter system.
- Monitor the pressure gauge on your filter (if applicable) to ensure proper flow.
- The pump is designed for continuous operation during filtration cycles.
3. Tiipa fifa soke
- Turn off the power to the pump at the circuit breaker or switch.
- Close any necessary valves if performing maintenance or winterizing.
Itoju
Itọju deedee n ṣe idaniloju iṣẹ ṣiṣe to dara julọ ati gigun igbesi aye fifa rẹ.
1. Cleaning the Pre-Filter Basket
- Pa fifa omi naa ki o si ti gbogbo awọn falifu ti o yẹ lati dena sisan omi.
- Unscrew the pre-filter nut and remove the lid.
- Lift out the pre-filter basket and empty any debris.
- Fi omi ṣan agbọn naa daradara.
- Inspect the O-ring on the lid for cracks or wear. Replace if necessary.
- Place the basket back into the housing, ensuring it is seated correctly.
- Replace the lid and tighten the pre-filter nut securely.
- Re-prime the pump as described in the "Operating Instructions" section.
2. Motor Care
- Keep the motor free from dirt, dust, and debris to ensure proper ventilation.
- Do not spray water directly onto the motor.
- Ṣayẹwo eyikeyi awọn ariwo dani tabi awọn gbigbọn lakoko iṣẹ.
3. Igba otutu
- In areas subject to freezing temperatures, the pump must be drained and protected.
- Turn off power to the pump.
- Drain all water from the pump by removing the drain plugs (if applicable) or disconnecting plumbing.
- Store the pump in a dry, frost-free location, or cover it adequately if it remains installed.
Laasigbotitusita
Abala yii n pese awọn ojutu si awọn ọran ti o wọpọ ti o le ba pade.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | No power; tripped breaker; faulty wiring; motor issue. | Check power supply, reset breaker, inspect wiring, consult a qualified electrician. |
| Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n kò ṣe pípèsè tàbí ó ní ìṣàn omi díẹ̀ | Air leak in suction line; clogged pre-filter basket; low water level; closed valves. | Check all connections for leaks, clean pre-filter basket, ensure adequate pool water level, open all valves. |
| Ariwo pupọ tabi gbigbọn | Air in system; cavitation; worn bearings; loose mounting. | Re-prime pump, check for obstructions in plumbing, ensure pump is securely mounted. If noise persists, contact service. |
| Omi jijo lati fifa | Loose connections; worn O-rings or seals; cracked housing. | Tighten connections, inspect and replace O-rings/seals, contact service for housing damage. |
Awọn pato
Detailed technical specifications for the Astral Pool Victoria Plus Pool Pump.
| Iwa | Iye |
|---|---|
| Brand | Astralpool |
| Nọmba awoṣe | part_B00J0CT5FK |
| Olupese | ATRAL |
| Ọja Mefa | 64 x 27 x 41 cm |
| Iwọn Nkan | 14.3 kilo |
| Iwọn | Ọdun 1.5 CV |
| Àwọ̀ | dudu |
| Ara | kilasika |
| Ohun elo | Polypropylene (PP) |
| Agbara Orisun Oriṣi | Okun Itanna |
| Voltage | 230 Volts |
| Nkan Package opoiye | 1 |
| Oṣuwọn sisan | 24 Cubic Metres Per Hour |
| Ẹgbẹ́ Ààbò Mọ́tò | IP-55 |
Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the official Astralpool webojula tabi kan si wọn onibara iṣẹ taara. Tọju iwe-ẹri rira rẹ bi ẹri rira fun eyikeyi awọn ibeere atilẹyin ọja.
For spare parts, please consult the manufacturer's official channels or authorized distributors.