Fluke FLUKE-T130

Fluke T130 Voltage ati Continuity Tester

Model: FLUKE-T130

Brand: Fluke

Ọrọ Iṣaaju

The Fluke T130 Voltage and Continuity Tester is a robust and reliable tool designed for electrical professionals. It features large, easy-to-use buttons, a bright backlit LED indicator, an LCD display, display hold, and clear audible and vibrating voltage indicators. This two-pole tester is essential for verifying the absence of voltage before working on any circuit, ensuring user safety and accurate measurements.

Fluke T130 Voltage ati Continuity Tester

Image: The Fluke T130 Voltage and Continuity Tester, showing its yellow body, black probes, backlit LCD, and LED indicators.

Alaye Aabo

Always observe standard safety precautions when working with electrical equipment. Failure to do so may result in injury or damage to the tester or equipment under test.

Ohun ti o wa ninu Apoti

The Fluke T130 package typically includes the following items:

Ṣeto

Fifi sori batiri

The Fluke T130 requires 2 AA batteries for operation. These are typically included. To install or replace batteries:

  1. Wa ideri iyẹwu batiri ni ẹhin oluyẹwo.
  2. Use a suitable tool (e.g., a screwdriver) to open the compartment.
  3. Fi awọn batiri AA meji sii, ki o rii daju pe polarity ti o tọ (+ ati -).
  4. Ni aabo pa ideri kompaktimenti batiri ni aabo.

Probe Tip Accessories

Attach the appropriate probe tip accessories (GS38 Probe Tip Sheath or 4 mm Ø Probe Extensions) as required for your measurement application. Ensure they are securely fitted to the probe tips.

Awọn ilana Iṣiṣẹ

The Fluke T130 offers multiple ways to indicate the presence of voltage, including LED indicators, an LCD display, an audible tone, and tactile feedback (vibration).

Voltage Idiwon

  1. Ensure the tester is clean and in good working condition.
  2. Connect the two probes to the circuit or component you wish to test.
  3. The tester will automatically detect AC or DC voltage and display the reading on the LCD.
  4. LED indicators will illuminate corresponding to voltage levels (e.g., 12V, 24V, 50V, 120V, 230V, 400V, 690V).
  5. An audible tone and vibration will also indicate the presence of voltage.
  6. Use the "Display Hold" function to freeze the reading on the LCD if needed.

Igbeyewo Ilọsiwaju

  1. Rí i dájú pé agbára ìṣiṣẹ́ náà ti dínkù kí o tó ṣe ìdánwò ìtẹ̀síwájú.
  2. Connect the two probes across the component or wire you want to test for continuity.
  3. If continuity is present (low resistance), the continuity LED will illuminate, and an audible tone will sound.

Switchable Load (Ghost Voltage Suppression)

The T130 features a switchable load function to avoid the display of "ghost voltages" (induced voltages in open circuits). Press the designated button to activate the load, which draws more current from the circuit under test, allowing for a more accurate voltage reading and preventing nuisance tripping of Residual Current Devices (RCDs).

Atọka Yiyi Alakoso

For three-phase systems, the T130 can indicate phase rotation. Follow the instructions in the full user manual for detailed steps on performing this test.

Itoju

Ninu

Clean the tester's case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the tester is dry before storage or use.

Batiri Rirọpo

Replace batteries when the low battery indicator appears on the LCD or when the tester's performance degrades. Refer to the "Battery Installation" section under Setup for instructions.

Ibi ipamọ

Store the tester in a dry, cool place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

Laasigbotitusita

IsoroOwun to le FaOjutu
Oluyẹwo ko ni agbara lori.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Ropo awọn batiri, aridaju ti o tọ polarity.
Aipe voltage kika.Ẹmi voltages; poor probe contact.Activate switchable load; ensure firm probe contact.
No continuity indication.Open circuit; faulty component.Verify circuit integrity; test component separately.
Ifihan LCD jẹ́ dídín tàbí kí ó máa tàn yòò.Batiri kekere.Rọpo awọn batiri.

Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
Nọmba awoṣeFLUKE-T130
Aabo RatingCAT IV 600 V, CAT III 690 V
Orisun agbaraAgbara Batiri (Batiri AA 2 to wa)
Ọja Mefa13.39 x 3.43 x 2.24 inches
Iwọn Nkan0.28 kilogram (9.88 iwon)
IfihanBacklit LCD readout, LED indicators
Voltage ItọkasiLED, LCD, Audible Tone, Tactile Feedback (Vibration)
Cable DurabilityDual insulated cable tested to 3x required bend angle
Pataki Awọn ẹya ara ẹrọSwitchable load (ghost voltage suppression), Display Hold
OlupeseFluke
Ilu isenbaleapapọ ijọba gẹẹsi

Atilẹyin ọja ati Support

Fluke products are known for their quality and reliability. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Fluke webojula.

Onibara Support

For technical assistance, troubleshooting, or service, please contact Fluke customer support. Contact information can typically be found on the Fluke webaaye tabi ni apoti ọja.

When contacting support, please have your product model number (FLUKE-T130) and serial number (if applicable) ready.

Awọn iwe aṣẹ ti o jọmọ - FLUKE-T130

Ṣaajuview Fluke T5-1000 / PRV240 Proving Unit Kit: Technical Data and Ordering Information
Comprehensive technical data and ordering information for the Fluke T5-1000 Electrical Tester and PRV240 Proving Unit Kit, detailing product specifications, components, and Fluke Corporation contact details.
Ṣaajuview Fluke 106/107 Oníná Oníná Oníná Oníná Pọ́ńpútà: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn àlàyé ìmọ̀-ẹ̀rọ tó kún rẹ́rẹ́, àwọn àkíyèsí ọjà, àti ìwífún gbogbogbò fún àwọn multimeter oní-nọ́ńbà Fluke 106 àti 107 tí wọ́n ní palms. Kọ́ nípa àwọn ìlànà iná mànàmáná wọn, ìṣedéédé wọn, àwọn ẹ̀yà ara wọn, àti àwọn ẹ̀rọ tí ó wà nínú wọn.
Ṣaajuview Fluke 110 True-RMS Multimeter: Àwọn Ìlànà Ìmọ̀-ẹ̀rọ àti Àwọn Ẹ̀yà Ara Rẹ̀
Àwọn ẹ̀kúnrẹ́rẹ́ àlàyé àti àwọn ẹ̀yà ara ẹ̀rọ Fluke 110 compact True-RMS multimeter, tí a ṣe fún fífi iná mànàmáná sí ipò tó péye àti ìṣòro. Ó ní ìṣedéédé, ìdíwọ̀n ààbò, àti àwọn ohun èlò míì tó wà nínú rẹ̀.
Ṣaajuview Fluke 305 Clamp Afowoyi olumulo Mita
Ìwé ìtọ́ni fún Fluke 305 Clamp Mita, pese alaye aabo alaye, awọn alaye ọja, ati itọsọna iṣiṣẹ fun awọn wiwọn ina deede.
Ṣaajuview Fluke 323/324/325 Clamp Afowoyi olumulo Mita
Ìwé ìtọ́nisọ́nà fún olùlò tó péye fún Fluke 323, 324, àti 325 clamp awọn mita, awọn ẹya alaye, awọn iṣọra aabo, awọn pato, ati itọsọna iṣiṣẹ fun awọn wiwọn ina mọnamọna deede.
Ṣaajuview Fluke 323/324/325 Clamp Ìwé Ìtọ́sọ́nà Olùlò Mita - Àwọn Ìlànà Pàtàkì àti Ààbò
Ìwé ìtọ́ni tó péye fún Fluke 323, 324, àti 325 Clamp Àwọn mita. Ó ní ìwífún nípa ààbò, àwọn ìlànà iná mànàmáná àti ẹ̀rọ, àti àwọn ìtọ́ni ìṣiṣẹ́.