Uponor 1013006

Atunṣe Itọju Ooru Unonor ST230, 230V, Àpẹẹrẹ 1013006 Ìwé Ìtọ́ni

1. Ifihan

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Uponor Thermal Actuator ST230, 230V, Model 1013006. Please read these instructions carefully before proceeding with installation or use. Retain this manual for future reference.

2. Ọja Ipariview

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for controlling the return valves on Uponor Vario S manifolds in underfloor heating systems. It operates on 230 Volts and features a screw connection IG M 30 x 1.5, a stroke indicator, and a 1.0-meter connection cable with wire end ferrules. The unit is splash-proof with an IP54 rating and is CE and RoHS certified.

Uponor Thermal Actuator ST230, 230V, Model 1013006

Nọmba 2.1: Uponor Thermal Actuator ST230, 230V, Model 1013006. This image shows the blue housing of the actuator with the Uponor logo and the grey screw connection base.

3. Alaye Aabo

  • Installation and electrical connections must be performed by a qualified electrician or authorized personnel in accordance with local regulations and standards.
  • Ensure the main power supply is disconnected before performing any installation, maintenance, or troubleshooting.
  • Do not open the actuator housing. There are no user-serviceable parts inside.
  • Protect the device from direct water spray or immersion, despite its splash-proof rating.
  • Use only genuine Uponor components and accessories.

4. Eto ati fifi sori

The thermal actuator is designed for easy mounting on Uponor Vario S manifold return valves. Follow these steps for proper installation:

  1. Ensure the heating system is depressurized and the manifold valves are in the correct position for actuator mounting.
  2. Carefully screw the actuator onto the valve connection (IG M 30 x 1.5) by hand until it is securely fastened. Do not overtighten.
  3. Connect the 230V electrical cable to the appropriate control unit or thermostat terminals. The cable is 0.75 mm² x 1.0 m and comes with wire end ferrules for secure connection.
  4. Verify all connections are secure and correctly wired according to the system's electrical diagram.
Diagram of Uponor Thermal Actuator with cable

Nọmba 4.1: Diagram showing the Uponor Thermal Actuator with its integrated connection cable. This illustrates the actuator's form factor and cable exit point.

Dimensional drawing of Uponor Thermal Actuator

Nọmba 4.2: Dimensional drawing of the Uponor Thermal Actuator, indicating key measurements (do, h, G) for installation planning. 'do' represents the outer diameter, 'h' the height, and 'G' the thread size.

5. Awọn ilana Iṣiṣẹ

The Uponor Thermal Actuator operates automatically in conjunction with a room thermostat or heating control system. When the control system signals a demand for heat, the actuator receives power, causing its internal element to expand and open the valve. When the heat demand is met, power is removed, and the actuator cools, closing the valve.

  • Stroke Indicator: The actuator is equipped with a stroke indicator, typically a small pin or window, which visually confirms the valve's open or closed position. Observe this indicator to verify proper operation.
  • Isẹ akọkọ: After installation and power-up, allow a short period for the actuator to respond to the control signal and fully open or close the valve.

6. Itọju

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for maintenance-free operation. No regular servicing or lubrication is required.

  • Keep the exterior of the actuator clean and free from dust or debris. Use a soft, dry cloth for cleaning.
  • Ma ṣe lo abrasive ose tabi epo.
  • Máa ṣàyẹ̀wò àwọn ìsopọ̀ iná mànàmáná lẹ́ẹ̀kọ̀ọ̀kan fún àmì ìbàjẹ́ tàbí ìbàjẹ́ èyíkéyìí.

7. Laasigbotitusita

If the thermal actuator is not functioning as expected, consider the following:

  • Actuator not opening/closing:
    • Check if the control system (thermostat) is calling for heat.
    • Verify that the actuator is receiving 230V power.
    • Ensure electrical connections are secure and correct.
    • Confirm the actuator is correctly screwed onto the valve.
  • No visible movement of stroke indicator:
    • Allow sufficient time for the actuator to react (thermal actuators have a delay).
    • Check power supply and control signal.

If issues persist after checking these points, contact qualified service personnel.

8. Awọn pato

Uponor Thermal Actuator ST230, 230V, Model 1013006 Technical Data Sheet

Nọmba 8.1: Technical data sheet for the Uponor Thermal Actuator ST230, 230V, Model 1013006, providing detailed specifications and contact information.

SipesifikesonuIye
BrandLori
Nọmba awoṣe1013006
OlupeseLori
Awọn iwọn Ọja (L x W x H)5 x 5 x 7.5 cm
Iwọn120 giramu
Voltage230 Volts
O pọju Voltage230 Volts
Asopọmọra IruSpade
Ohun elo olubasọrọIrin ti ko njepata
Ohun elo idaboboPolyolefin
Ebute IruIbùdó Spade
Ni ibamu Awọn alayeCE, RoHS
Ilu isenbaleJẹmánì
Kóòdù Abala Àgbáyé (EAN)04021598002937
Okun Asopọmọra0.75 mm² x 1.0 m, without plug, with wire end ferrules
Kilasi IdaaboboIP54 (Imudaniloju Asesejade)
àtọwọdá AsopọScrew connection IG M 30 x 1.5
Ẹya ara ẹrọAtọka ikọlu

9. Atilẹyin ọja ati Support

Uponor products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Uponor directly. Information regarding spare parts availability is not provided in the product specifications.

Ibi iwifunni:

Lori GmbH

Ile-iṣẹ 56

97437 Hassfurt

Jẹmánì

Tẹlifoonu: + 4932210090856

Imeeli: Kundenservice@uponor.com

Webojula: www.uponor.com/de-de

Awọn iwe aṣẹ ti o jọmọ - 1013006

Ṣaajuview Igbona ati Itutu Abẹ Ilẹ Uponor: Itọsọna Alaye Eto
Ìtọ́sọ́nà ètò tó péye láti ọ̀dọ̀ Uponor ṣe àlàyé nípa àwọn ètò ìgbóná àti ìtútù lábẹ́ ilẹ̀, tó bo àwọn ìlànà ìmọ̀-ẹ̀rọ, àwọn ìlànà ìṣètò, àwọn ìlànà fífi sori ẹrọ, àti ìwọ̀ntúnwọ̀nsì hydraulic fún àwọn ojútùú ìṣàkóso ojú ọjọ́ tó dára jùlọ.
Ṣaajuview Ilana fifi sori ẹrọ lori Alailẹgbẹ
Iwe afọwọkọ yii n pese alaye awọn ilana fifi sori ẹrọ fun Eto Alailẹgbẹ Uponor, pẹlu fifi paipu, asopọ onilọpo, ati idanwo titẹ. O ni wiwa awọn igbesẹ ti o ṣe pataki fun aṣeyọri ati fifi sori ẹrọ daradara ti eto alapapo ilẹ ti Uponor Classic.
Ṣaajuview Uponor Vario / Vario PLUS Actuator Installation and Technical Manual
Comprehensive guide to the Uponor Vario and Vario PLUS actuators, covering installation, operation, features like 'First-Open', and detailed technical specifications for HVAC systems.
Ṣaajuview Uponor Vario Retrofit Actuator: Installation Guide and Technical Specifications
Comprehensive guide to installing and operating the Uponor Vario retrofit actuator, including detailed technical specifications, compatibility information, and safety instructions for HVAC systems.
Ṣaajuview Uponor Siccus Mini: Alapapo Labẹ ilẹ Gbẹ ati Awọn pato Imọ-ẹrọ Eto Itutu agbaiye
Alaye imọ-ẹrọ ti okeerẹ fun Uponor Siccus Mini alapapo ilẹ abẹlẹ ati itutu giga giga. Awọn apejuwe eto ni wiwa, awọn anfani, awọn paati, igbero, fifi sori ẹrọ, ati awọn alaye imọ-ẹrọ alaye fun isọdọtun ibugbe.
Ṣaajuview Uponor Combi Port E-Hybrid Quick Guide - Installation and Operation
This quick guide provides essential information for the installation and operation of the Uponor Combi Port E-Hybrid heat interface unit. It covers general safety, component identification, hydraulic and electrical installation, filling, flushing, testing, and visual inspection procedures.